GTR 76577639
Tenders Are Invited For Dk 021:2015: 50420000-5 Services For Repair And Maintenance Of Medical And Surgical Equipment (Services For Current Repair And Maintenance Of Medical And Surgical Equipment)
ICB — International Competitive Bid
Closed
Eastern Europe
Tender Information
GTR Reference
76577639
Tendering Authority
Subscribe to view
Tender No
UA-2024-02-14-002882-a
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Dk 021:2015: 50420000-5 Services For Repair And Maintenance Of Medical And Surgical Equipment (Services For Current Repair And Maintenance Of Medical And Surgical Equipment)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Eastern Europe
Political Region
Commonwealth of Independent States CIS
Last Date of Bid Submission
22-02-2024
Closed
Work Detail
Services For Repair And Maintenance Of Bactericidal Irradiated Bactosfera (Disassembly, Restoration Of Contacts, Replacement Of 30W Lamp, Assembly, Function Check), Services For Repair And Maintenance Of Physiotron-2 Apparatus Factory Number 11844 Inventory Number 1137270 (Technical Diagnostics, Repair Of Electronic Board With Replacement Damaged Components, Setup, Function Check), Labline-010 Analyzer Repair And Maintenance Services Factory Number 142510 Inventory Number 101450187 (Technical Diagnostics, Disassembly, Power Chain Repair (Real Time Measurement Channel), Setup, Function Check), Repair Services And Technical Maintenance Of The Penion Рм-9000 Patient Monitor Factory Number W5clb1398aioqr (Technical Diagnostics, Housing Repair (Fixing Elements And Power Supply Unit Elements), Replacement Of The System Memory Power Supply Element, Installation Of Network Cable, Blood Saturation Measuring Sensor, Pneumatic Chamber And Cuffs Of The Arterial Measurement Channel Pressure, Patient Cable (Ekg Signal Measurement Channel), Setup, Function Check), Electrocardiograph Repair And Maintenance Services Mydas 6/12 Factory Number 4532 Inventory Number 1014710004 (Technical Diagnostics, Ecg Signal Recorder Repair, Patient Cable Testing, Setup, Check Functioning), Services For Repair And Maintenance Of Mindray Patient Monitor Rm-8000 Factory Number Aa-93114852; 85107856; 85107857; 85107858 (Technical Diagnostics, Replacement Of The Electrical Seat, Measuring Sensor Of Blood Saturation, Pneumomer And Cuffs Of The Channel Of Blood Pressure Measurement, Adjustment, Check-Up, Repair And Maintenance Services Of The Penlon Pm-9000 Diagnostic Monitor; Zamo-9000; Blood Saturation Measuring Sensor, Pneumatic Chamber And Blood Pressure Measuring Channel Cuff, Patient Cable (Ekg Signal Measuring Channel), Setup, Function Check), Penlon Rm-9000 Patient Monitor Repair And Maintenance Services Factory Number W5clb1397aioqr (Technical Diagnostics, Power Plug Replacement; Air Pressure Tube And Cuff Installation, Patient Cable (Ecg Signal Measurement Channel), Setup, Functional Check), Penlon Rm-9000 Patient Monitor Repair And Maintenance Services Factory Number W4clb0727qs (Technical Diagnostics, Real Time Measurement Channel Repair With Replacement) Damaged Components, Replacement Of System Memory Power Supply, Installation Of Air Chamber And Blood Pressure Channel Cuff, Patient Cable (Ecg Signal Channel), Setup, Functionality Check), Penlon Rm-8000 Patient Monitor Repair And Maintenance Service Factory Number Aa6a-14080Qr (Technical Diagnostics, Replacement Of The System Memory Power Supply Element
Key Value
Tender Value
48,930 - UAH
Tender Documents
Global Tender Document
668510ec-5dfe-4996-a102-6565d2b9890b.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer