GTR 75938479
Tenders Are Invited For Extension Of The Sports Hall Building With A Building Of The Primary School With A Kindergarten In The Town Of Sieniawa - Stage Iii
ICB — International Competitive Bid
Closed
Central Europe
Tender Information
GTR Reference
75938479
Tendering Authority
Subscribe to view
Tender No
RIN.271.5.2024
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Extension Of The Sports Hall Building With A Building Of The Primary School With A Kindergarten In The Town Of Sieniawa - Stage Iii
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
15-02-2024
Closed
Work Detail
1. Subject Of The Order: The Subject Of The Order Is The Expansion Of The Sports Hall Building With A Building Of The Primary School With A Kindergarten In The Town Of Sieniawa - Stage Iii. The Scope Of Implementation Includes The Expansion Of The Sports Hall Building With A Building Of The Primary School In Sieniawa, On Plots No. 819/2, 818 /1, 818/5, 818/7 - Interior Finishing Works. The Primary School Building On An H-Shaped Plan, Two-Story, Partially Basement, With Maximum External Dimensions Of 59.64X34.44 M, With A Flat Single-Slope Roof, With Attics And A Single-Story Batten With Dimensions 8.1X3.28 M To The Existing Sports Hall Building. Parameters Of The Expanded Part: 1) Development Area: 1538.5 M22) Total Area: 3472.6 M23) Usable Area: 3011.66 M24) Cubature: 11028.69 M3 Works Covered By Stage Iii: Expanded Part – School: Execution Of Finishing Layers Of Plaster And Painting, Application Of A Protective Layer For Painting, Using Water-Based Varnish Up To A Height Of Approx. 2 M From The Floor Level, Execution Of Suspended Coffered Ceilings (In Classrooms, Kindergartens, Multi-Purpose Rooms, Communication Rooms, Office Rooms - Ceilings In Sound Absorption Class Min. C), Construction Of Suspended Coffered Ceilings (In Sanitary Facilities - Ceilings With Minimum Moisture Resistance Rh 90%), Construction Of System Suspended Ceilings On A Steel Grid Made Of Metal Plates Or Ceiling Panels Laminated With Pvc Foil, With Minimum Moisture Resistance Rh 90%, With The Possibility Of Wet Cleaning, In Kitchen Facilities (Rooms No. 1.45; 1.46; 1.47; 1.48; 1.49; 1.50; 1.51), Installation Of Vapor-Proof Foil On All Suspended Ceilings, Floor Leveling Layers For Plastic Floor Coverings, Floor Coverings Finishing Layers (Plastic Floors), Installation Of Hpl Walls/Partitions, Installation Of Internal Wooden Door Leaves Complete With Fittings, Installation Of White Assemblies Internally. Water And Sewage Installations, Including Sanitary Equipment For The Disabled, Installation Of White Installations Of Central Heating Installations, Installation Of Internal White Installations. Electrical Installations, Including Sanitary Equipment For The Disabled, Low-Current Installations, Insulating The Walls Of The Extended Part (School): Insulating The Styrofoam Panels, With Mineral Wool (Fire Partition Walls), Light-Wet Method, With Thin-Layer Silicone Coating, Installation Of Sheet Metal Flashings, Installation Of Internal And External Balustrades, Installation Of Internal And External System Doormats, Implementation Of The Design-Build System, Connection Of The Building To The Sanitary, Storm, Gas And Electricity Sewage Systems, Development Of The Area (Sidewalks, Internal Roads, Parking Lot, Field Stairs , Lighting The Area Around The Building, Planting The Area Around The Building, Forming Slopes, Topsoiling With Fertile Soil And Sowing With Grass. Existing Part - Sports Hall: - Insulating The Walls, Using The Same Technology As In The Expanded Part, - Replacing Sheet Metal Flashings In Connection With Insulating The Walls, In Technology As In The Expanded Part, Replacement Of Aluminum Joinery (Windows) In The Existing Part (Sports Hall): • Quantity: 8 Pieces, • Fixed Windows, • Dimensions S=2400Mm, H=4500Mm,• Window Division: 1200Mm X 1500Mm X 6 Pcs.,• Color Of Profiles And Fittings: Silver Or Gray,• Three-Glazed Unit, With Safety Glass On The Inside,• Required Window Thermal Transmittance Coefficient Uw ≤ 0.9W /(M2*K). The Detailed Scope Of The Order Can Be Found In The Design Documentation, Technical Specifications, Bills Of Quantities, And Answers To.2. The Subject Of The Order Must Be Performed In Accordance With The Design Documentation - Annex No. 7 To The Swz: (Due To The Lump-Sum Settlement, The Submitted Bills Of Quantities Are Only Of Auxiliary Nature And Do Not Constitute The Basis For The Valuation Of The Offer). - The Principles Of Technical Knowledge, The Currently Applicable Construction Law Together With The Documents Executive And Occupational Health And Safety Regulations.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
8831111a-3a52-4a45-9aed-4cbe040ac9b9.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.