GTR 75127150

Tenders Are Invited For Electrical Installation Work - Electrical Engineering, V0739/2023, Oberneuland School & Daycare Center

ICB — International Competitive Bid Closed Western Europe
Tender Information
GTR Reference
75127150
Tendering Authority
Subscribe to view
Tender No
27142-2024
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Electrical Installation Work - Electrical Engineering, V0739/2023, Oberneuland School & Daycare Center
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Western Europe
Political Region
European Union,G20
Last Date of Bid Submission
12-02-2024 Closed
Work Detail
Electrical Installation Work - Electrical Engineering, V0739/2023, Oberneuland School & Daycare Center. Primary School: 442 Own Power Supply Systems The New Primary School Building Will Have Safety Lighting Fitted. Central Battery Unit Is Installed In The Technical Room On The Ground Floor. Security And Exit Sign Lights = In Led Technology In The Building = No General Lighting Lights For Safety Lighting Safety Lights To Illuminate The Areas To Be Highlighted Places Such As Fire Extinguishers, Hand Push Button Alarms, Etc. Are Taken Into Account. Security Lighting In The Outdoor Space = Planning By Horeis+Blatt. Here Are In The Security Lighting Center The Required Disposals Are Kept As Specified. Services Such As Delivery And Mounting The Lights Outdoors, Laying Cables, Cable Trenches, Etc. Are Not Included The Tga. Building A = New Nursing Room To Be Created With Standby Light. On The A Pv System Without Storage Is Taken Into Account In The New Building. 444 Low-Voltage Installation Systems One Main Building Distribution Per Floor + Sub-Distribution. Kitchen = Own Electrical Distribution Intended. The Lighting In Hallways And Toilets Is Switched On As Needed Using Local Presence Detectors. Kitchen + Cafeteria + Technical Rooms Will Be The Lighting Switched On Site. Nursing Room In Building A = Lighting Controlled Via Presence Detector Building C = Suspended Lighting In The Music Room Switched On Site. For Routing Collection Holders Are Used For Installations Such As Lights, Smoke Detectors, Presence Detectors, Etc Installed From Metal. In The Classrooms = Vertical Parapet Channels Installed, Which Accommodate The Data Double Sockets And Sockets. The Number Of Data Sockets And Sockets Refers To The Information In Accordance With The October It Infrastructure Construction Standard 2019. The Building Will Be Equipped With External Sun Protection. The Control Takes Place Via A Weather Station, Which Enables Automatic Shading. Overcontrol In The Room Is Possible Using Key Shutter Switches. The Necessary Cables And Lines Are Taken Into Account. Systems Such As Rwa Systems, Automatic Doors, Hold-Open Systems Etc. Only Receive A 230V Power Connection. Crossings And Isolations Opposite Necessary Corridors/Stairwells And Fire Compartments Are Carried Out Using Installation Materials Suitable For This Purpose And Approved By The Building Authorities. In The Area Two Sockets Are Installed In The Bicycle Parking Spaces For Teachers For Charging The Batteries Of E-Bikes. 445 Lighting System Lighting = Complete In Led Technology Light Lines Are Attached To The Suspended Ceiling In The Classrooms, Hallways And Cafeteria Assembled. The Reinforcements That May Be Necessary For This Are Part Of The Service Drop Ceiling. Toilets = Built-In Downlights, Staircase = Wall Lights, Technical Rooms + Ventilation Center = Damp Room Luminaires Building Exits = Lights For Security Lighting Be Used. 449 Other Construction Site Power Distributors Are Used Within The Building Electrical Supply To The Areas Is Provided. The Circulation Areas (Stairwells And Hallways) Are Equipped With Construction Lighting, Supplied By The Construction Power Distributors. No Workplace Lighting Will Be Installed. Elephant Childrens Circle: 442 Self-Powered Power Systems The Daycare Extension Will Be Equipped With Safety Lighting. Central Battery Device = Technical Room On The 1St Floor Safety And Escape Sign Lights = Led Technology In The Building No General Lighting Luminaires Are Used For Security Lighting. The Safety Lights To Illuminate The Areas That Need To Be Highlighted, Such As Fire Extinguishers, Hand Push Button Detectors Etc. Are Taken Into Account. Outdoor Security Lighting = Planning By Horeis+Blatt Office Here In The Safety Lighting Center The Required Disposals Are Kept As Specified. Services Such As Delivery And Mounting The Lights Outdoors, Laying Cables, Cable Trenches, Etc. Are Not Included The Tga. A Pv System Without Storage Is Included In The Daycare Extension. 444 Low-Voltage Installation Systems In The Building = Main Building Distribution And Each A Sub-Distribution On The Floor. Since Daycare With Bedrooms = Arc Fault Protection Devices (Afdds) According To Din Vde 0100-420 For Use In Single-Phase Alternating Current Circuits Up To 16A Come. Kitchen Existing Construction = Own Electrical Distribution Circuit Lighting Is Done In The Hallways And Toilets As Needed Using Local Presence Detectors. Kitchen + Technical Rooms = Lighting Switched On Site. For Cable Routing To The Installations Such As Lights, Smoke Detectors, Presence Detectors, Etc., Metal Collection Holders Are Installed. The Installations Such As Switches, Sockets And Data Sockets Are Primarily Flush-Mounted Manufactured. The Building Will Be Equipped With External Sun Protection. It Is Controlled Via A Weather Station, Which Provides Automatic Shading Enabled. Overcontrol In The Room Is Possible Using Key Shutter Switches. The Required Cables And Lines Are Taken Into Account. Systems Such As Rwa Systems, Automatic Doors, Hold-Open Systems, Etc. Only Receive A 230V Power Connection. Crossings And Partitions From Necessary Corridors/Stairwells And Fire Compartments Are Carried Out Using Suitable Installation Materials Approved By The Building Authorities. 445 Lighting System Lighting = Led Technology Groups + Bedrooms = Round Surface-Mounted Ceiling Lights With Different Diameters (If Necessary Reinforcements = Part Of The Suspended Ceiling) Wcs + Hallways = Built-In Downlights, Staircase = Wall Lights, Technical Rooms + Ventilation Center = Wet Room Trough Lights Building Exits = Lights Which Are For Safety Lighting Can Be Used 449 Other Inside The Building = Building Power Distributor For Electrical Supply To The Areas The Traffic Areas (Staircases + Corridors) = Construction Lighting (Supplied By Construction Power Distributors) No Workplace Lighting.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
c1bbaa47-bce9-4938-9605-99dbfc8d6217.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you