GTR 74257899

Tenders Are Invited For Modernization Of The Swimming Pool Operation System At The Józef Piłsudski Academy Of Physical Education In Warsaw, Branch In Biała Podlaska

ICB — International Competitive Bid Closed Central Europe
Tender Information
GTR Reference
74257899
Tendering Authority
Subscribe to view
Tender No
SSZP 371/16/2023/B
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Modernization Of The Swimming Pool Operation System At The Józef Piłsudski Academy Of Physical Education In Warsaw, Branch In Biała Podlaska
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
03-01-2024 Closed
Work Detail
1. The Subject Of The Order Is The Modernization Of The Swimming Pool Service System At The Józef Piłsudski Academy Of Physical Education In Warsaw, Branch In Biała Podlaska, Ul. Akademicka 2. The Modernization Will Consist In Replacing Hpl Cabinets With Electronically Controlled Locks, Controllers, Envelopes With A Transponder For Belts And Readers Compatible With The Existing Esok System At The J. Piłsudski University Of Physical Education In Warsaw Branch In Biała Podlaska Ul. Akademicka 2. A Solution For Locking Lockers Is Planned Based On Controllers And Collective Readers As Well As Electronic Locks That Do Not Require Battery Power. The Offered Subject Of The Order Cannot Disturb Or Reduce The Quality Of The Services Offered By The Swimming Pool. Required Functionalities For The Modernization Of The Esok System: ● Possibility To Configure And Manage Lockers From The Level Esok System, I.E. Through Separate Functions In The Program;● Possibility To Mark Locker Statuses In The Esok System (Active/Disabled/Damaged) Along With Automatic Locking Of The Locker For Users Of A Facility With A Status Other Than Active;● Possibility To Generate A Report On The Use Of The Locker At Any Time Period Of Time. 1) Type 2S Lockers For Two People In One Body, One Above The Other With A Bench, Four Rows Each In The Mens And Womens Cloakroom, 93 Pieces Compliant With The Minimum Requirements: - Cabinet Structure On Aluminum Profiles; - Door, Base, Shelf Made Of Hpl Laminate, 10 Mm Thick, Characterized By High Resistance To Bending And Tearing, High Surface Hardness, Resistance To Dirt, Thermal Resistance; - Total Height 1800 Mm (Body 1500 Mm); - Width 350 Mm;- Depth 485 Mm;- Frame 300 Mm High, Adjustable;- 30 Cm Wide Bench, Uniform Along The Entire Length;- Hinges Made Of Stainless Steel; - Double Hanger Made Of Material Resistant To Difficult Conditions; - Handle Enabling Opening The Door; - Cover For Cables From The Controller To The Lock; - Permanent Engraved Numbering With A Digit Height Of 50 Cm - Sticked Or Painted Numbering Is Not Allowed; - Colors - To Be Agreed After Signing The Contract .2) 186 Locks And 8 Controllers With Dynamic Locker Allocation Function. The Lockers Will Be Controlled Using A Collective Reader With An Lcd Display Using Mifare Rfid Technology Placed At The Top Of Each Row Of Lockers, Visible Immediately After Entering The Cloakroom. The Client Assigns The Strip To The Controller In The Following Way: - The Client With The Strip Issued In Esok Approaches The Cabinet Controller, Which Communicates With The Controller, Dynamically Assigning The Cabinet; - The Cabinet Is Released Automatically After Settling The Bill Assigned To A Given Transponder Strip; - In The Case Of Applying Transponder Strip To A Controller That Does Not Support The Cabinet Already Assigned To This Strip, The Touch Screen Will Display Information Indicating To The Customer The Number Of His Cabinet. The Electromagnetic Cabinet Lock Should Be Adapted To Places With Particularly Difficult Working Conditions And Must Meet The Following Requirements: ● It Is Resistant To Moisture;● It Is Waterproof;● It Has A Door-Breaking Mechanism;● It Has The Ability To Open The Lock In An Emergency Without Having To Break The Hinges. The Lock Controller Should Be Adapted To Places With Particularly Difficult Working Conditions And Must Meet The Following Requirements:● Has A Protection Level Of Ip65● Is Resistant To Moisture;● Is Waterproof;● Supports At Least 30 Cabinet Locks;● Maximum 10 Addresses On The Bus;● Supports At Least 30 Feedback Signals From Locks;● Has The Ability To Emergency Open The Cabinet Lock (Physical Button For Emergency Opening Of All Cabinets Assigned To The Controller - Unavailable From The Swimming Pool Client Level). Control Of Cabinet Locks Depends On The Cabinet Controllers To Which The Locks Are Connected And On Dedicated Software. The Controller Is To Work In Dynamic Mode, While Configuration Should Be Done From A Pc After Establishing An Online Connection. The Cabinet Must Be Able To Be Opened In The Event Of A Main Power Failure (From The Central Ups Or From The Battery Set Installed In The Controller) And Loss Of Communication With The Esok Server. The Ups Should Contain A Minimum Apparent Power Of 3K Va.3) Readers With An Lcd Display - 8 Pcs., Information Points (Time Reading) With An Lcd Display - 3 Pcs., And Transponder Stripe Readers At The Cash Register - 2 Pcs. Esok Software Should Be Expanded With Dynamic Locker Allocation After Applying The Transponder Strip To The Reader With An Lcd Display In The Cloakroom. The Locker Control System Must Be Based On A Dynamic Allocation System So That Any Bar Can Open Any Locker. All Cabinets Should Be Selected Evenly. The Power Supply For The System Components Must Be Provided Continuously, Which Excludes The Use Of Battery-Based Solutions In Cloakrooms (Also For Environmental Protection Reasons).4) Belt Envelopes With A Mifare Rfid Transponder - Colors To Be Determined At The Implementation Stage, Quantity Of 540 Pcs.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
36625263-dfb5-4ad5-99e6-121e1a5451cb.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders