GTR 72157024
Tenders Are Invited For Adaptation Of Primary School No. 2 In Wałcz, Ul. Marii Konopnicka 2 To Fire Protection Requirements. - Stage Ii (Fire Alarm System, Ssp And Construction Works).
ICB — International Competitive Bid
Closed
Central Europe
Tender Information
GTR Reference
72157024
Tendering Authority
Subscribe to view
Tender No
IRP.271.28.2023
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Adaptation Of Primary School No. 2 In Wałcz, Ul. Marii Konopnicka 2 To Fire Protection Requirements. - Stage Ii (Fire Alarm System, Ssp And Construction Works).
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
17-11-2023
Closed
Work Detail
The Subject Of The Order Is The Adaptation Of Primary School No. 2 In Wałcz To Fire Protection Requirements - Stage Ii (Fire Alarm Signaling System Ssp And Construction Works) Through: 1) Construction Of A Fire Alarm Signaling System Ssp: Equipping The Main Building With A Fire Alarm System (Total Protection Of The Main Building Without Transmitting Alarm Signals To The State Fire Service, Only To The Place Of Permanent Supervision - Security Company). Smoke Exhaust Control Units For Staircases A, B And C Should Be Connected To The Fire System. The Fire System Will Also Control The Passenger Elevator And Ei69 Fire Curtains In The Area Of Staircase B.2) Implementation Of A Smoke Exhaust System For Staircases C And A, And Emergency Lighting In Staircase A. :- Staircase C Smoke Exhaust System - Windows In The Attic - Disassembly Of Actuators, Installation Of New Actuators After Replacing Windows, Connection To The Existing Smoke Exhaust Control Unit, Programming And Commissioning; - Staircase A Smoke Exhaust System - Reconstruction Of The Entrance Door In The Staircase - Installation Of A New Door Actuator , Connection To The Existing Smoke Exhaust Control Panel, Programming And Commissioning; - Installation Of New Emergency And Evacuation Fixtures Over The Reconstructed Entrance Door. 3) Execution Of Construction Works: A) Ground Floor: - Replacement Of The Existing Wooden Doors With Frames With Aluminum Ones With Fire Resistance Class Ei30 And Eis30 ;- Construction Of A Thick Brick Partition Wall. 12 Cm Made Of Solid Brick With Plaster On Both Sides And Installation Of Eis30 Aluminum Doors In The Staircase A; - In The Doors Of Existing Rooms No. 04 And 05, Door Closers Should Be Installed To Secure The Passage Through The Escape Route; - A Fire Curtain Should Be Installed On The Outside Of The Window In The Staircase B. B) Ground Floor: - Replacement Of The Existing Wooden Door With The Frame With An Aluminum One With Fire Resistance Class Eis60 In The Connector At Gymnasium; - Construction Of A Thick Brick Partition Wall. 12 Cm Made Of Solid Brick With Plaster On Both Sides And Installation Of Eis30 Aluminum Doors In The Corridor Next To The Passenger Lift; - Construction Of A Glazed, Fire-Resistant Aluminum Ei30 Partition Wall And Installation Of A New Door In Room No. 1.9; - Construction Of A Brick Partition Wall, Thickness 12 Cm Made Of Solid Brick With Plaster On Both Sides And Installation Of Aluminum Or Wooden Smoke-Proof Doors In The Form Existing In The Adjacent Wall (To Be Dismantled); - Installation Of Door Closers And Smoke-Tight Seals In Existing Doors; - Replacement Of Windows In Staircase A With New Aluminum Ones With Actuators; - Installation Of Actuators In Existing Windows In Staircase C; - Removal Of Brickwork In Staircase No. 1.20 (Main Entrance) And Installation Of Wooden Doors Reproducing The Form Of Existing Ones (Or Renovation); - Removal Of Internal Doors At The Exit From The Staircase B. C) Ground Floor, Gymnasium: - Replacement Of Existing Wooden Doors With Frames With Aluminum Ones With Fire Resistance Class Ei30 And Smoke-Tight. D) 1St Floor: - Installation Of Door Closers And Smoke-Tight Seals In Existing Doors.E) 2Nd Floor: - Installation Of Door Closers And Smoke-Tight Seals In Existing Doors; - From The Outside Of The Windows In The Corridor No. 3.11, First Room. Fire Curtains Should Be Installed In The Backroom No. 3.10. F) Attic: - Replacement Of Existing Wooden Doors With Frames With Aluminum Ones With Fire Resistance Class Eis30; - Replacement Of Windows In Frame C With New Aluminum Ones With Actuators; - In The Attic, The Roof Truss Elements Should Be Painted Twice With A Fire Retardant Protecting The Elements To The Nro Class (Non-Flame Spreading). The Detailed Scope Of Work Is Included In The Design Documentation, Which Constitutes Appendices To The Swz
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
b21c5381-1ef5-4c86-a878-444ca94d61a6.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.