GTR 70915307

Tenders Are Invited For Supplying Connections (Cable Joint And Termination Accessories For Power Cable )

NCB — National Competitive Bid Closed Western Asia
Tender Information
GTR Reference
70915307
Tendering Authority
Subscribe to view
Tender No
113/2023
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Supplying Connections (Cable Joint And Termination Accessories For Power Cable )
Bid Type
NCB — National Competitive Bid
Country
Subscribe to view
Geographical Region
Western Asia
Political Region
Arab World,Middle East,Middle East and North Africa MENA
Last Date of Bid Submission
10-10-2023 Closed
Work Detail
Tenders Are Invited For Supplying Connections (Cable Joint And Termination Accessories For Power Cable ) Supply Of Links. 1. General Xlpe Cables Shall Be Terminated And Jointed With Suitable Terminating Kits And Shall Be Of The Blocking Type Designed That Prevents The Ingress Of Moisture From One Cable To The Next Through The Through Joints. The Straight Through Joint Kit Or Termination Shall Be Complete With All Accessories, Jointing Material, Insulating Stress Control And Sealing Material, Lugs, Nuts, Bolts Etc. As Well As An Instruction Booklet Explaining The Method Of Using The Kit And It Shall Be Complied With Iec 60502. The Straight Through Joints Should Be Absolutely Impervious To The Entry Of Water. The Manufacturer Shall Use The Proven Technologies And Design To Ensure A Construction Which Will Prevent Entry Of Water Or Any Other Liquid Inside The Straight Through Joint And Cable. 1.1 General Requirements For Straight Joint And Terminations Each Kit Shall Be Provided With All Necessary Insulation Materials And Other Accessories, Cable Lugs Must Be Tinned Copper Suitable For Connection Cu, Al, Al Alloy, Acsr On Copper Terminals Or Aluminium Terminals. Cable Lugs Inside Covered With Contact Grease For A Best Electrical Contact, Closed By Protection Cap. It Shall Be Suitable For Crimping By Hexagonal Compression, Where All Accessories Shall Be Dry & Clean. Red Anti-Tracking Mastic The Red Anti-Tracking Mastic Must Be Suitable For Power Cable Heat Shrink Outdoor Termination And Joints For 12 And 36 Kv To Provide Insulation And Sealing. The Red Mastic Shall Not Flow Or Exude At Temperature Below 85Oc. Each Kit Shall Be Provided With All Necessary Insulation Materials, Grounding Kit And Other Accessories, The Thickness Of Insulated Material Should Comply With The Min Thickness Of CableS Insulation. Designs, Drawings And Details Of All Terminations, Quantified Materials To Be Used, With Copies Of Instructions Shall Be Submitted For Approval By The Engineer Before The Factory Orders Are Issued For Manufacture 1.2 Condition Of Operation And Rating: The Cables Where Laid In The Ground Shall Be Rated To Suit The Following Conditions:- A) Depth Of Laying 1.0 M B) Ground Temperature 40Oc At 1.0 M Depth C) Soil Thermal Resistivity 2 C M / W D) Spacing Between Circuits 0.6 M [Disclaimer: The Above Text Is Machine Translated. For Accurate Information Kindly Refer The Original Document.] Tender Link : Https://Www.Edco.Jo/Tenderspages/Activetenders
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
8ca547a3-bb62-4d41-b45c-9389a085f0b0.htm
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders