Tenders Are Invited For Execution Of The Air-Conditioning System In Buildings A And B Of The District Office In Pleszew

ICB — International Competitive Bid Closed Central Europe
Tender Information
GTR Reference
67969898
Tendering Authority
Subscribe to view
Tender No
NR.272.11.2023
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Execution Of The Air-Conditioning System In Buildings A And B Of The District Office In Pleszew
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
16-08-2023 Closed
Work Detail
1. The Subject Of The Order Is The Execution Of An Air-Conditioning System For Buildings A And B Of The District Office In Pleszew. 2. The Order Includes The Installation Of 7 Outdoor Condensing Units And 20 Pieces Of Wall-Mounted Air Conditioners With A System Power Of 2 Kw. Devices Must Meet At Least The Following Parameters: 2.1. Condensing Units: 2.1.1). Condensing Unit 1: Ground Floor Left Side And Second Floor Left Side: Number Of Devices: 2, Heating Power: Min. 9 Kw, Cooling Capacity: Min. 7.5 Kw, Electric Power: 2.11 Kw ± 10%, Warranty Period: Min. 60 Months 2.1.2). Condensing Unit 2: Ground Floor Right Side, First Floor Right And Left Side, Second Floor Right Side: Number Of Devices: 4, Heating Power: Min. 6.5 Kw, Cooling Capacity: Min. 5.0 Kw, Electric Power: 1.25 ± 10%, Warranty: Min. 60 Months 2.1.3). Condensing Unit 3: Passage Between Buildings A And B: Number Of Devices: 1, Cooling Capacity: Min. 10 Kw, Electric Power: 3.77 ± 10%, Warranty: Min. 60 Months 2.2. Indoor Air Conditioners: Number Of Devices: 20, Nominal Cooling Capacity: Min. 2.0 Kw, Nominal Heating Power: Min. 2.5 Kw, Device Efficiency: Cop (Heating Performance Coefficient): Min. 4.0, Eer (Coefficient Of Performance): Min.7.0, Dc Inverter Technology, Refrigerant: Meeting Current Regulations, Operating Modes: Auto, Cooling, Heating, Ventilation, Two-Way Airflow, Heating Function: At Least + 10C, Airflow Adjustment, Timer: Daily, Periodic, Energy Class: Cooling: Min. A++ , Heating (Average): Min. A+, Airflow Regulation: Remote Control. 3. During The Warranty Period (Manufacturers Warranty), The Contractor Will Be Obliged To Perform The Required Inspections And Maintenance. Inspections And Maintenance Will Be Carried Out With The Frequency In Accordance With The Manufacturers Recommendations. 4. During The Warranty Period, The Contractor Will Be Obliged To Take Actions Related To The Removal Of The Failure Within 3 Working Days (72 Hours) From The Moment Of Notification (Note: The Response Time Of The Service Is A Criterion For The Evaluation Of Bids). Failure Removal Activities Will Include The Arrival Of A Service Technician On Site, Finding The Failure And Taking Action To Remove The Failure. 5. A Detailed Description Of The Subject Of The Order Is Included In The Technical Documentation Constituting Annexes I-Ii To The Tor.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
0be267c2-4bce-4680-98b6-fe97bccbb9e7.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders