GTR 67568285
Tenders Are Invited For Delivery And Assembly Of Roofed Sports Stands At The Main Pitch At The Sports And Recreation Center In Kłodzko
ICB — International Competitive Bid
Closed
Central Europe
Tender Information
GTR Reference
67568285
Tendering Authority
Subscribe to view
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Delivery And Assembly Of Roofed Sports Stands At The Main Pitch At The Sports And Recreation Center In Kłodzko
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
28-07-2023
Closed
Work Detail
The Subject Of The Contract Is The Delivery And Assembly Of Sports Stands At The Main Pitch At The Sports And Recreation Center In Kłodzko. Tribune Structure: 4-Row Roofed Tribune With Seats. The Tribune And The Roofing Are In Accordance With The Design Documentation Attached To This Tender - Dimensions, Shape, Profile Cross-Sections, Roof Slope Are Preserved. Number Of Stands: 3 Pcs. With The Currently Applicable Safety Regulations And Standards Pn-En 13200-1: 2019-05, Pn-En13200-3-2018-12 Regarding The Audience. The Construction Of The Stand Meets The Construction Standards: • Standard Combinations According To Pn-En 1990:2004 • Permanent Loads: Pn-En 1991-1-1:2004; • Snow Load: Pn-En 1991-1-3:2005; • Wind Load: Pn-En 1991-1-4:2008; • Dimensioning Of The Steel Structure: Pn-En 1993 -1:2005, Pn-En 1993-1-8;• Dimensioning Of The Reinforced Concrete Structure: Pn-En 1992-1-1:2008;• Dimensioning Of Foundations: Pn-En 1997-1:2008;The Design Of The Grandstand Developed On The Basis Of Calculations Taking Into Account The Location Of The Grandstand In The Third Wind Zone And The First Snow Zone. Confirming The Fulfillment Of The Above Assumptions. The Structure Of The Tribune Is Made Of Steel Profiles, Protected Against Corrosion By Hot-Dip Galvanizing Technology. Ends Of Closed Profiles Protected Against Corrosion, I.E. Inserts Made Of Plastic To Avoid Water Accumulation. Step Height 20 Cm. Passage Width Between Fixed Elements In Rows Min. 50Cm. The Width Of The Emergency Exits Is 140 Cm. Platform The Platforms Of The Tribune Are Made Of A Grating Type: Pressed, Made Of A Steel Load-Bearing Flat Bar 30X2 Mm, Eye 44X44 Mm, Protected Against Corrosion By Hot-Dip Galvanizing According To Pn-En Iso 1461. The Gratings Have A Technical Approval Of The Building Research Institute In Warsaw (The Institute Is A Member Of The European Union For Technical Acceptance In Construction Ueatc And The Organization For Technical Approvals - Eota). Canopy Structure Roof Structure Made Of Steel Profiles, Protected Against Corrosion By Hot-Dip Galvanizing Technology. Roofing Of The Tribune Made Of Colorless Cellular Polycarbonate, 10 Mm Thick, With A Coating Protecting Against Uv Rays. The Ends Of The Closed Profiles Are Protected Against Corrosion, I.E. With Inserts Made Of Plastic To Avoid Water Accumulation. Seats Seats With A Backrest, 30 Cm High, Made By Injection Molding Based On Polypropylene Enriched With Additives Preventing Artificial Aging Due To Uv Radiation And Flame Retardant In A Proportion That Ensures Compliance With The Flammability Standards Required By Law. In The Color Chosen By The Investor. The Seat Has The Following Certificates And Documents: • Hygienic Certificate, Strength Test Certificate In Terms Of Safety Of Use, Fire Classification Confirming Its Low Flammability, Classification In Terms Of Toxicity Of Decomposition And Combustion Products Confirming Compliance With The Polish Standard. I: Material Certificate • Hot-Dip Galvanizing: Quality Certificate In Accordance With The Pn En Iso 1461 Standard • Polycarbonate: Declaration Of Performance, Bridge Cards, Declaration Of Performance • Seats: Hygienic Certificate, Strength Test Report, Flammability Test Report3) Complete Design Calculations In Accordance With The Standards: • Standard Combinations According To Pn-En 1990:2004• Permanent Loads: Pn-En 1991-1-1:2004;• Snow Load: Pn-En 1991-1-3:2005;• Wind Load: Pn-En 1991-1-4:2008;• Steel Structure Design: Pn-En 1993-1:2005, Pn-En 1993-1-8;• Reinforced Concrete Structure Design: Pn-En 199 2-1-1:2008;• Dimensioning Of Foundations: Pn-En 1997-1:2008 Grandstand Design Developed On The Basis Of Calculations Taking Into Account The Location Of The Tribune In Wind Zone Iii And Snow Zone I. All Proper Names Of Products And Materials As Well As Quality Standards Referred To In The Documentation Are Used To Determine The Desired Standard Of Execution And To Determine The Properties And Technical Requirements Assumed For The Technical Documentation For Given Solutions. Equivalent Solutions (Based On Products From Other Manufacturers) Are Allowed, Provided That The Same Technical Characteristics Are Met In Accordance With The Relevant Provisions Of The Technical Documentation. Execution And Acceptance Of The Works As Well As The Materials Used Must Comply With The Applicable Pn (En-Pn), Relevant Standards Of Eu Countries Or Equivalent Quality Standards.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
43179f72-cbad-443a-a22c-4174c7d98e3f.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.