GTR 63726652
Tenders Are Invited For Renovation Of A Single-Family Residential Building At Maćkowa Ruda 57
ICB — International Competitive Bid
Closed
Central Europe
Tender Information
GTR Reference
63726652
Tendering Authority
Subscribe to view
Tender No
AGB-212/20/2023
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Renovation Of A Single-Family Residential Building At Maćkowa Ruda 57
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
09-05-2023
Closed
Work Detail
1) Renovation Of The Façade And Roofing. Demolition Of The Existing Ceramic Tile Coverings, Repair Of Stair Steps And Execution Of Stone Cladding On The Front Stairs And Entrances To The Residential Part, Approx. 40 M2 - Slabs At Least 1.5 Cm Thick, Royal Granite Pattern. Flamed Stone Steps, Polished Stone Risers. The Cladding Was Designed To Be Made Of Cut Boards Available In The Market In The Dimensions Of 60 X 60 Cm Or 30 X 60 Cmb. Disassembly Of The Existing Canopy Above The Front Door And Making A New One From Aluminum Profiles, Fixed Directly To The Wall Without Posts Or On Two Posts That Are An Integral Part Of The Balustrade. Cover Cellular Polycarbonate.C. Demolition Of The Existing Steel Railings And Construction Of New Stainless Steel Railings - Front Stairs And Stairs Of The Porch On The Gable Wall.D. Demolition Of The Existing Strips And Concrete Slabs Adjacent To The Building, Approx. 60 M2e. Excavation Of The Foundations And Execution Of Thermal Insulation (Extruded Polystyrene Foam, Thickness 8-10 Cm, Approx. 72 M2 F. Execution Of New Bands And Pavements Made Of Concrete Cubes (Pattern Similar To The Old Paving Stones, Color Gray Or Graphite) Approx. 60 M2 Plus 81 Running Meters. Cleaning, Washing And Repairing Plasters On External Walls, Including The Entrance To The Basement, Approx. And Laying A Thin-Layer Colored In-Mass Silicone Plaster Or Silicone Silicate Plaster, Lamb Pattern, Color To Be Selected During The Implementation. The Cornice Was Designed To Be Made Of Polystyrene Moldings, 8-10 Cm Thick, Approx. 61 R.M. Execution Of Thermal Insulation Of The Attic Wall Separating The Residential Part From The Unheated One, Made Of Hard Mineral Wool, Thickness 20 Cm. The Surface Of The Insulation Is Protected With A Mesh Embedded In Glue And Painted With Facade Paint. Approx. 25 M2l. Replacement Of Wooden Basement Windows, 7 Pieces, With Pvc Windows With A Coefficient U Not Greater Than 1.1 W/(M² K). Color White.M. Replacement Of Part Of The Ground Floor Windows (Wood And Pvc) With Pvc Windows - 7 Three-Section Windows And 4 Attic Windows. U-Value Not Greater Than 0.9 W/(M² K) And 2 Pieces U Not Greater Than 1.1 W/(M² K) (Unheated Porch And Attic) Color Whiten. Repair Of Jambs After Replacing Windows O. Replacement Of External Entrance Doors To The Building With Insulated Steel Ones, Including: A) 1 Pc. (Main Entrance) Door With Side Transoms, Wing 90 Cm Plus 2 Transoms, 30 Cm Each. U Coefficient Not Greater Than 1.1 W/(M² K)B) 2 Single Units With Built-In Transom Light 80 Cm Entry To The Porch U Coefficient Not Greater Than 1.5 W/(M² K)C) 1 Piece Solid Door U Coefficient Not Greater Than 1.5 W/(M²·K) Basement Entrance P. Roofing Replacement Approx. Coating For Which The Manufacturer Provides At Least A 25-Year Warranty, Including: A) Disassembly And Reassembly Of Roof Windows 6 Pcs B) Disassembly And Reassembly Of Solar Collectors 3 Panels) Execution Of The Missing Thermal Insulation With Mineral Wool Of Residential Attics And Supplementing The Existing Insulation In Places To Which There Is No Access Without Removing The Roof Covering (Slants). Approx. 50 M2, Assumed Insulation Thickness 15 - 20 Cm. D) Installation Of A Glazed Roof Hatch With Opening Dimensions Not Smaller Than 49 X 76 Cm - 1 Pc. E) Installation Of Footings 88 Cm - 11 Pcs. And Steps Made Of Coated Steel In The Color Of The Roof Covering 5 Piecesf) Installation Of Snow Fences Made Of Coated Steel In The Color Of The Roof Covering 66 M.G) Installation Of Gutters D=150 Mm, Approx. 76 M And Down Pipes D=110 Mm - Approx. External Window Sills Made Of Steel Sheet Coated In The Color Of The Roof Covering.I) Installation Of A Lightning Protection System (Air Rods Fixed To The Roofing Sheet And Pins On The Chimneys)J) Removal Of The Roof Stand And Making A Cable Connection From The Residential Building To The Outbuilding, Connection Length Approx. 20 M
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
5e5b3cf5-20d5-413d-952c-3f84bd1ff2a1.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.