GTR 63408673

Tenders Are Invited For Construction Of A Workshop Building On The Premises Of Przedsiębiorstwo Gospodarki Komunalnej Sp. Z O.O. With Its Registered Office In Biłgoraj

ICB — International Competitive Bid Closed Central Europe
Tender Information
GTR Reference
63408673
Tendering Authority
Subscribe to view
Tender No
ZP/DOT/1/23
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Construction Of A Workshop Building On The Premises Of Przedsiębiorstwo Gospodarki Komunalnej Sp. Z O.O. With Its Registered Office In Biłgoraj
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
04-05-2023 Closed
Work Detail
The Subject Of The Contract Are Demolition And Construction Works Consisting In The Construction Of A Workshop Building Located On Plot No. 18/26 In Biłgoraj, Ul. Łąkowa 13. 1. As Part Of The Task, The Following Should Be Performed: 1.1. Demolition Of The Existing Building, Filling In The Basement Existing Below The Ground Level Along With Soil Compaction: 1.1.1. Demolition Of The Existing Building Marked With The Symbol No. 2 On The Site Fire Pit In The Scope Of: - Demolition Of The Roof Covering Approx. 106.29 M2 - Dismantling Of Downpipes, Usable Approx. 5.4 M - Dismantling Of Metal Gutters, Usable Approx. 13, 5 R.M. - Dismantling Of Flashings: Fire Walls, Collar Eaves, Cornices, Etc. Made Of Unusable Sheet Metal, Approx. 6.7 M2 - Demolition Works, Reinforced Concrete Elements Approx. ·Cm 10.13 M3 - Demolition Of Walls, Pillars, Columns Made Of Bricks, On Lime Mortar 27.46 M3 - Demolition Works, Reinforced Concrete Elements 1.6 M3 - Scrap Removal And Disposal Of Demolished Elements - Backfilling The Area After Demolition With Sand And Leveling The Area. 1.2. Construction Of A Workshop Building In Accordance With The Attached Design: 1.2.1. A Building With A Steel Structure Filled With A Sandwich Panel With A Mineral Wool Core With Structural Dimensions: 4.1.2. Width - 7.36 M4.1.3. Length 16.0 M, 4.1.4. Height - 7.05 M4.1.5. Roof Slope Angle 5.0°4.1.6. Building Area 117.6 M²4.1.7. Usable Area 106.73 M²4.1.8. Execution Of Reinforced Foundation Footings Together With Fixing Anchors.4.1.9. Steel Structure Of The Main Columns Made Of Square Profiles 140X140x84.1.10. The Rigidity Of The Structure Is Ensured By The Construction Of Frames With Transoms Connected To The Columns With Rigid Nodes By The Use Of Welded Connections And By The Use Of X-Bracings Made Of Fi 184.1.11 Bars. Roofing Made Of A Sandwich Panel With A Polyurethane Core, Flashings Of Eaves And Roof Edges Made Of Coated Steel And Metal Sheets. Pvc Roof Gutters And Downpipes4.1.12. Workshop Drive-On Pit Made Of Concrete Blocks, Medium-Type Two-Component Waterproofing From The Outside, Or Execution Of A Drive-On Pit From Concrete 30W8 (Formwork And Concrete Pouring) While Maintaining Two-Component Waterproofing Provided For Constructions Made Of Concrete Blocks, Walls Finished With A Ceramic Plate From The Inside, Channel Floor 1 Cm Thick Terracotta With Non-Slip Coating4.1.13. The Floor Of The Workshop Building - Industrial, 15 Cm Thick, Made Of C20/25 Concrete, A Well With Mechanical Draining Of Liquids Located In The Middle Of The Sewer Floor In Accordance With The Construction Design. 4.1.14. Channel Equipped With Steel Steps On Both Sides, Electrical Installation Including Lighting In Accordance With The Design.4.1.15. The Employer Requires The Execution Of A Pneumatic System Not Included In The Design. The Contractor Is Obliged To Prepare A Pneumatic System Design On Its Own In Agreement With The Employer And The Author Of The Design For The Construction And Construction Industry.4.1.15.1. The Employer Requires The Design Of 3 Points Located On The Eastern Wall Of The Designed Workshop Building At A Distance Of Approx. 3 M. The 4Th Point Should Be Placed In The Designed Working Channel. 4.1.15.2. The Design Should Include A Connection To The Existing Compressor Station Located On The North Side Of The Designed Building At A Distance Of Approx. 15 M (A Diagram Of The Target Location Of The Installation Is Attached).4.1.15.3. After The Installation Is Completed, The Contractor Will Carry Out The Appropriate Acceptance And Tightness Tests. 1.3. Works In The Field Of Sanitary Industry Should Be Carried Out In Accordance With The Attached Design: 1.3.1. Installation Of The Internal Central Heating System According To The Design, The Sanitary Industry.1.3.2. Installation Of Mechanical Ventilation Of The Duct And Workshop Room In Accordance With The Design Of The Sanitary Industry.1.3.3. Attention!!! The Employer Informs That He Withdraws From The Construction Of Internal And External Sanitary Installations And Hot And Cold Water Supply Systems. 1.3.4. According To The Attached Project In The Field Of Sanitary Industry, The Employer Requires The Execution Of A Full Range Of Central Heating Installations. And Installation Of Mechanical Ventilation. 1.4. Electrical Works Should Be Carried Out In Accordance With The Attached Design: 1.4.1. Execution Of Foundation Grounding1.4.2. Laying Electrical Installation Pipes1.4.3. Laying Cables1.4.4. Assembly And Equipment Of Switchgears1.4.5. Connection Works1.4.6. Assembly Of Electrical Equipment1.4.7. Execution Of The Lightning Protection System1.4.8. Post-Assembly Measurements1.4.9. Lighting Installation, 1.4.10. Socket Installation,1.4.11. Force Installation, 1.4.12. Assembly Of Electrical Equipment, 1.4.13. Assembly Of Lighting Fixtures, 1.5. Attention!! Change In The Design In Terms Of The Description Of Drawing A Contained In The Architectural And Construction Design Hv Industrial Sectional Doors: 1.5.1. Gate No. 1 From The Southern Entrance: 1.5.1.1. Sectional, Automatic Industrial Door 1.5.1.2. Height 45001.5.1.3. Width 45001.5.1.4. Guidance With An Overhang To Make Maximum Use Of The Workshop Height1.5.1.5. Panel Color Ral 9006 1.5.1.6. Silkline Or Smooth Structure (To Be Agreed With The Ordering Party)1.5.1.7. No Ribs1.5.1.8. Se -9 Automatik Operator For Gates With An Area Of ​​About 26 M2 With A Ts-970 Control Panel, 3X400v Power Supply, Electronic Limit Switch, Safety Edge Strip Or Equivalent System1.5.1.9. Safety Brake On Both Sides Of The Gate (Protection In Case Of Cable Damage Or Breakage)1.5.1.10. Universal Radio Link, 4 Four-Channel Remote Controls1.5.1.11. 2 Glazing With Aluminum Panel (Panel 3 And 4)1.5.1.12. Left Wicket Door Equipped With An Opening Sensor And A Door Closer1.5.2. Gate No. 2 From The North Side: 1.5.2.1. Sectional, Automatic Industrial Door 1.5.2.2. Height 45001.5.2.3. Width 45001.5.2.4. Guidance With An Elevation Allowing Maximum Use Of The Workshop Height1.5.2.5. Panel Color Ral 90061.5.2.6. Silkline Or Smooth Structure (To Be Agreed With The Ordering Party)1.5.2.7. No Ribs1.5.2.8. Se-9 Automatik Operator For Gates With An Area Of ​​About 26 M2 With A Ts-970 Control Panel, 3X400v Power Supply, Electronic Limit Switch, Safety Edge Strip Or Equivalent System1.5.2.9. Safety Brake On Both Sides Of The Gate In Case Of Cable Damage Or Breakage1.5.2.10. Universal Radio Path1.5.2.11. 2 Glazing With Aluminum Panel (Panel 3 And 4)1.5.2.12. Attention!!!! The Project Was Supplemented With A Drawing Of The Gate Substructure With Steel Structure Elements Enabling The Assembly Of Structural Elements Of Sectional Doors.1.6. Attention!!! The Technological Equipment Specified In Figure T 1 And The Description Of The File Named Technology Does Not Fall Within The Scope Of The Proceedings, The Following Equipment: A) Tool Cabinet - 3 Items; B) Tool Cabinet - 1 Item; C) Channel Hydraulic Jack - 1 Item; D) A Device For Setting Lights - 1 Piece; E) A Heater - 1 Piece; F) A Washbasin - 1 Piece; G) A Water Heater - 1 Piece; – 3 Piecesc) Ventilation In The Roof – 1 Pieced) Sectional Doors - 2 Pieces1.6.1. Guarantee: The Ordering Party Requires Min. 60 Months Warranty For The Construction Works Performed, And Min. 24 Months Warranty On Industrial Automatic Sectional Doors.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
75c34762-5647-467b-b4ef-ffaec911c857.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders