GTR 61729630

Tenders Are Invited For Renovation Of Buildings No. 15 And 16 In Knw At Ul. Dąbrowskiego In Elbląg - Stage Ii.

ICB — International Competitive Bid Closed Central Europe
Tender Information
GTR Reference
61729630
Tendering Authority
Subscribe to view
Tender No
21WOG-SZP.2712.11.2023
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Renovation Of Buildings No. 15 And 16 In Knw At Ul. Dąbrowskiego In Elbląg - Stage Ii.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
23-03-2023 Closed
Work Detail
The Subject Of The Contract Is: Renovation Of Buildings No. 15 And 16 In Knw At Ul. Dąbrowski In Elbląg - Stage Ii. Construction: Building No. 15 And No. 16 On The Premises Of The Elbląg Warehouse - 2 Rblog In Knw At Ul. Dąbrowskiego 35 In Elbląg. The Scope Of Works Includes: Building No. 151. Floors And Floors - Demolition Of The Concrete Floor, - Securing The Gates With A Tarpaulin For The Duration Of The Works, - Cutting Concrete Floors, - Mechanical Demolition Of Concrete Elements, - Making A Concrete Floor (Concrete B-30), - Waste Disposal And Disposal. 2.Installation Of Gates. 7 Gates With Service Doors And 11 Gates Without Service Doors Should Be Installed In The Building. Due To The Historic Nature Of The Facility And The Existing 9 New Gates In The Same Building, The Gates Must Be Visually And Design Identical (Color, Shape Of Window Seals, Division And Shape Of Flashings, Connections Between The Wall And The Frame). Doors With The Following Parameters: - Garage Folding Door Should Operate With The Use Of Trolleys On The Track System, Which Enables Manual Operation Of The Door, - As A Standard, The Door Should Be Equipped With All Accessories Necessary For Manual Operation With An Emergency Lever, Which Should Be Set In The Locked Position, - Curtain The Gate Is Made Of Double-Walled Segments, 55 Mm Thick, Made Of Galvanized Steel Sheet, - The Perimeter Frame Of The Leaf Is Made Of A Shaped Dovetail Profile Made Of Sheet Metal, 2 Mm, Aluminum Profile With A Brush From The Bottom, - Segments Are Filled With Cfc-Free Polyurethane Foam With A Density Greater Than 40 Kg/M3, Covered With Smooth, Varnished Sheet Metal, 0.8 Mm Thick, - Upper Guide Made Of Galvanized Steel, 2 Mm Thick - Side Guides Made Of Aluminum, After Installation Ensure Good Stability And Fastening Of The Gate, - Hinges Made Of Aluminum Equipped With A Pin And Double Bearing Ensuring Good Mobility Of The Leaves, - Upper Trolleys Are To Consist Of Three Nylon Wheels Ensuring Silent Operation Of The Gate, - For To Close The Gate, Use Bolts Mounted Inside The Gate, Equipped With Rods For Closing From The Top And Bottom. The Ends Of The Rods Should Be Reinforced, - The Internal Closure Of The Gate Is Ensured By A Pvc Blockade Installed In The Ground, - The Handles Closing The Bolts Must Be At A Height Accessible To A Short Person, - The Gate Should Have 50 Mm Thick Rubber Seals, Installed Between The Leaves And Made Of Natural Epdm, - The Gate Is Equipped With Transoms With Dimensions Of 500 Mm Wide And 600 Mm High, Installed In Each Leaf In The Upper Part Of The Gate, Acrylic Safety Glass, Opaque But Light-Transmitting. Louvered Steel, Dimensions: Width 600 Mm And Height 300 Mm, Black, And From The Inside An Air Supply Grille Equipped With An Adjustment Enabling Its Closing. Independent Lock, (Applies To 7 Gates) - Gate Wings Should Be Equipped With A Blockade In The Form Of An Aluminum Latch Anchored In A Sleeve Mounted In The Concrete Slab Of The Car Park, Which Prevents Uncontrolled Closing Of The Leaves After Opening The Gates, - The Gates Should Be Equipped With Additional Stainless Steel Handles For Closing The Padlock, Which Also Act As A Sealing Device. - Gates Painted In A Color Ral 9006, - When Replacing The Gates, The External And Internal Parts Of The Concrete Entrance Must Be Replaced And A Steel Gw Angle Bar Reinforcing The Threshold Should Be Installed. The Existing Old Steel Door Frame Embedded In The Door Frame Should Be Repaired, Cleaned And Painted Anti-Corrosive. - On The Maneuvering Area At The Gates There Are Concrete Resistors That Need To Be Removed. In Place Of These Resistors, Install Resistors Made Of Thick-Walled Steel Pipes Fi 200, 150 Cm Long. The Resistor Is To Be Sunk 50 Cm Into A Concrete Footing Placed At A Depth Of 1 M. Below The Ground Level (The Protruding Part Is To Be 100 Cm Long). The Posts Are To Be Painted In Yellow And Black Stripes. - If Damage To The Gate Lintels And Jambs Is Found During The Execution Of Works, They Must Be Repaired. 3. Replacement Of Window Frames - Disassembly Of The Existing Window Frames In Storage Rooms Office And Stairwells, - Installation Of New Pvc Window Joinery In The Amount Of 28 Pcs. With Dimensions: A) 26 Pcs - Width 132 Cm X Height 152 Cm - White Pvc Double-Sash Windows With Symmetrical Vertical Division, One Casement Sash, The Other Sash Turn-And-Tilt, Thermal Transmittance May Not Exceed 0.9 W/(M² K )B) 2 Pieces - Width 132 Cm X Height 330 Cm - White Pvc Windows, Thermal Transmittance May Not Exceed 0.9 W/(M² K ), Window Division According To The Following Sketch. The Upper Half Of The Window Was Fixed, In The Lower Part One Sash Was Tilt And Turn, The Other Sash. Fixed Bars Made Of Stiles (Not Glued). Handles Locked With A Key. Diagrams Of Windows Can Be Found At - Installation Of External Galvanized Steel Window Sills, Dimensions 150 Cm X 30 Cm - Number Of 28 Pcs. Plastering Jambs (Replacing Casement Windows With Composite Windows) - Repair Filling After Replacing Windows - Painting Window Walls And Jambs With White Emulsion Paint With Increased Abrasion Resistance If Necessary, Furniture Interfering With Construction Works Should Be Moved. After Completing The Works, Wash The Floors And Other Elements. 4. Renovation Of The Electrical System - Replacement Of Lighting And Surface-Mounted Electrical Installation In 10 Garage Rooms, - Led Hanging Lamps 2X 18 W With A Replaceable Light Source, Dustproof Ip 55, Length 120 Cm - Number Of 81 Lamps - Replacement Of 10 Surface-Mounted Switches, - Replacement Of The 230 V Socket Supply System (Surface-Mounted) - 40 Points, - Replacement Of The Three-Phase Installation, 6 Points, - Replacement Of 2 Electrical Switchgears, 48 ​​Bays (Ip 67). One Switchgear Equipped With: Main Switch 60 A, Overcurrent Circuit Breaker 32 A - 3 Pieces, Overcurrent Circuit Breaker B10 - 5 Pieces, Overcurrent Circuit Breaker B16 - 5 Pieces, Three-Phase Combined Overcurrent Circuit Breaker B20 - 3 Pieces, - Replacement Of Lightning Rods With Pvc Tubes Adjacent To The Wall. Building No. 161. Floors And Floors - Demolition Of A Part Of The Concrete Floor Of The Garage Entrance - 2 Entrances, - Securing The Gates With A Tarpaulin For The Duration Of The Works, - Cutting Concrete Substrates, - Mechanical Demolition Of Concrete Elements, - Execution Of A Concrete Floor (Concrete B-30), - Assembly Of A Steel Threshold Made Of Gw Angle Bar, - Removal And Disposal Of Waste. A) 1 Pcs - Width 150 Cm X Height 165 Cm - White Pvc Double-Sash Windows With Symmetrical Vertical Division, One Casement Sash, The Other Sash Tilt And Turn, Thermal Insulation Cannot Be Higher Than 0.9 W/(M² K ) B) 1 Piece - Width 108 Cm X Height 158 ​​Cm - White Pvc Windows, Double Sash With Symmetrical Vertical Division, One Casement Casement, The Other Casement Casement Hinged, Thermal Permeability Cannot Be Higher Than 0.9 W/(M² K )C)1 Item - Width 120 Cm X Height 148 Cm - White Pvc Windows, Double Sash With Symmetrical Vertical Division, One Sash Casement, The Other Sash Turn-And-Tilt, Thermal Transmittance May Not Be Higher Than 0.9 W/(M² K )D) 2 Pieces - Width 150 Cm X Height 164 Cm - White Pvc Windows, Double Sash With Symmetrical Vertical Division, One Sash Casement, Second Tilt-And-Turn Sash, Thermal Transmittance May Not Be Higher Than 0.9 W/(M² K ) - Installation Of Galvanized Steel External Window Sills - Installation Of System Pvc Internal Window Sills - Narrowing Of The Internal Light Of Window Openings By Building And Plastering Jambs (Replacement Of Casement Windows For Combined Windows) - Preparation Painting Window Walls - Repair Filling After Replacing Windows - Painting Window Walls And Jambs With White Emulsion Paint With Increased Resistance To Abrasion - Removal And Disposal Of Rubble And Waste From The Construction Site, Works On The Implementation Of The Task In Question Should Be Based On The Latest Construction Technologies And Technical Solutions That Meet The Requirements Contained In Polish Standards, Ensuring Safe And Compliant Storage Of Material Resources And User Comfort. The Technical Solutions And Devices Used Must Meet The Requirements For Safety In The Operation Of Storage Rooms, Evacuation Of Equipment And Property, And Fire Protection. Works, The Requirements Contained In The Applicable Regulations And Standards For This Type Of Work Should Be Taken Into Account When Implementing The Subject Of The Order. A Detailed Description Of The Subject Of The Order Is Included In Annexes 1 And 4 To The Tor. And The Maximum Scoring Guarantee And Warranty Period Is 60 Months.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
83dfc1fe-9efb-4a9a-97f1-bdb21b397bb7.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders