GTR 61688050

Tenders Are Invited For Procurement Of Laboratory Equipment For Smarter Onelab For Industry 4.0 Through Testing And Calibration, Education Anf Discovery Project (Bid No. 2023-01),Laboratory Supplies And Equipment

ICB — International Competitive Bid Closed South Eastern Asia
Tender Information
GTR Reference
61688050
Tendering Authority
Subscribe to view
Tender No
2023-03-023
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Procurement Of Laboratory Equipment For Smarter Onelab For Industry 4.0 Through Testing And Calibration, Education Anf Discovery Project (Bid No. 2023-01),Laboratory Supplies And Equipment
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South Eastern Asia
Political Region
Asia Pacific Economic Cooperation APEC,Association of Southeast Asian Nations ASEAN,APAC Asia Pacific
Last Date of Bid Submission
27-03-2023 Closed
Work Detail
Dual Magnetron Of About 1900 Watts Or Higher; -Large Microwave Cavity Minimum Of 70.5L; - 2 Sets Of Segmented Rotor, (I) Capable Of High Pressure (Upto 100 Bar) And Temperature (Upto 300C) Digestion Upto 15 Placer Or Higher, (Ii) Capable Of 40 Or M,Multi-Mode Sample Introduction System The Multimode Sample Introduction System Capable Of Simultaneous Vapor Generation For As And Se; Enables Measurement Of Major And Minor Elements In The Same Run; Plus Additional Spare Msis Assembly; To Include,Type I Water Producer Or Water Deionizer; -Product Water Must Be A High Quality Reagent Water With Resistivity Of 18.2 Mω-Cm, Conductivity Of <0.1Μmho/Cm, And Sio2 Of <0.05Mg/L, Toc Of ≤ 5 Ppb; -Uses Continuous Electrodeionization Technology For,Digital Bottletop Burette; - 50Ml Capacity; - No Exposed Glassware, -Angled Dighital Display, - Turning Wheels Capable Of Dispensing And Displaying 0.01 To 999.9 Ml, -Continuous Pulse-Free Vibrations, With Safety Recirculating Valve, - All Co,Complete Mercury Detection System; - Requires No Digestion And Sample Preparation; - Fast Analysis Maximum Of 6 Minutes; - Includes At Least 20 Quartz Sample Boats And 20 Metal Boats, And 20- Or More Placer For Auto-Sampler System; -No Spectral,Benchtop 1100 Or 1200 C Muffle Furnace; - 350 Cubic Inch Volume Capacity Or Similar, - Digital Temperature Display And With Programmable Temperature Control (C1 Controller), - Built-In Vent System And Overtemp Protection Control; -Heavy-Duty Door,6-Placer Or More, Hotplate With Magnetic Stirrers Or Enclosed Water Bath; -Transparent Chamber For Visibility And Temperature Resistant; - Enclosed System With Temperature Regulation And Overheating Controls; -To Include Filtration System Or Fibe,Twin Room (2 Chamber- Incubator) - Temperature Range: -5⁰C To 70⁰C, Adjustable - Accuracy: ± 0.2⁰C - Digital Display - Approx. 500 L Volume (Approx. 250 L Volume Per Chamber) - Separate Temperature Setting Per Chamber - At Least 3 Shelves Per Cham,Automatic Autoclave, Vertical Loading Type, Power: 220V-240V - 50L-60L Chamber Capacity, Stainless Steel - Working Temp & Pressure: Adjustable 105-136Oc/±0.5Oc Accuracy, 0-3Kg/Cm2, - With Temperature And Pressure Digital Display - Adjustable T,Molecular Detection System (For The Detection Of Food Pathogens) A. Molecular Detection System Machine (Main Unit) - Rapidly Detects Salmonella Spp, Listeria Spp., Listeria Monocytogenes, Campylobacter Spp., E.Coli O157:H7, Cronobacter Spp. Using Dna,Temperature Range: Ambient +5⁰C To 100⁰C, Adjustable - Accuracy: ± 0.1⁰C - Digital Display - Approx. 50-60 L Volume - Stainless Steel Shelves - Stainless Steel Interior Material - Over/Under Temperature Protector Safety Device - Double Door (Tempere,Temperature Range: 0⁰C To 70⁰C, Adjustable - Compressor-Cooled Incubator - Accuracy: ± 0.1⁰C - Digital Display - Approx. 50-60 L Volume - Stainless Steel Shelves - Stainless Steel Interior Material - Over/Under Temperature Protector Safety Device,Circulating Coliform Water Bath - 35-40 L Bath Volume Capacity - Temperature Range: Ambient + 5 ºc To 100 ºc - Digital Temperature Setting/ Adjustment - Accuracy Of ± 0.1 ºc - Resolution Of 0.1 ºc - Digital Display - Stainless Steel Chamber - With Bu,With Ph Electrode, Conductivity/Atc Probe, Integral Electrode Holder & Vac Adapter - To Include Other Testing Parameters For Mv, Saturation, Salinity, Partial Pressure, Dissolved Oxygen, Total Dissolved Solids And Salinity,Capacity: At Least 220 G Readability: 0.1 Mg Or Better Minimum Weight: At Most 20 Mg Built-In Calibration Weight Must Be Compliant With Usp Chapter 41 Display: Wear Resistant Led Touchscreen Including: Installation, Commissioning; Training, Warranty,Reference Pressure Gauge, -12 To 500 Psi (Resolution: 0.01 Psi),Reference Pressure Gauge, -15 To 30 Psi (Resolution: 0.001 Psi),Capacity: -90 °C To Ambient Temperature Resolution: 0.01 °C Compatible With Thermocouple Type K Automatic Internal Reference Junction Compensation Sample Rate: Capable Of 10 Channels Per Second At Least 9 Channels Display Resolution: 6 1/2 Digits Can,Field Metrology Well/Multi-Channel Data Logger Capacity: -90 °C To Ambient To 660 °C Temperature Resolution: 0.01 °C At Least 9 Channels All Channels Isolated For Temperature Measurements. Preferably: Capable Of Measuring Humidity Aside From Temperat,Type 304 Stainless Steel Scale Resolution: 5 Mm Tolerance: 0.02% Scale Accuracy Equipped With A (Liquid-Level) Gauge Tube Mounted On The Side Of The Neck Built To Oiml R-120 Grip: Rubber On Test Measure Handle Volume Indication: Aluminum Graduated Sc,Type 304 Stainless Steel Scale Resolution: 5 Mm Tolerance: 0.02% Scale Accuracy Equipped With A (Liquid-Level) Gauge Tube Mounted On The Side Of The Neck Built To Oiml R-120 Grip: Rubber On Test Measure Handle Volume Indication: Aluminum Graduated Sc,Nominal Value/S: 1 Kg, 2 Kg, 5 Kg, 10 Kg Material: Stainless Steel Shape: Cylindrical With Handling Knob Inclusion: With Wooden Box
Key Value
Tender Value
2,599,000,000 - PHP
Tender Documents
Global Tender Document
c8605206-1e20-41cf-9c50-dd30622427ea.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders