GTR 61054151

Tenders Are Invited For Thermal Modernization Of The Building Of The Municipal Social Welfare Centre

ICB — International Competitive Bid Closed Central Europe
Tender Information
GTR Reference
61054151
Tendering Authority
Subscribe to view
Tender No
BMK-RZP.272.1.5.2023
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Thermal Modernization Of The Building Of The Municipal Social Welfare Centre
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
09-03-2023 Closed
Work Detail
The Subject Of The Contract Is The Performance Of 1) Thermal Modernization Of The Mops Building In Luboń, Consisting Of: - Disassembly Of The Existing Roof Covering With Elements Of Equipment; - Disassembly And Reassembly Of The Lightning Protection System - Assembly / Replacement Of 3 Cm Battens And 4 Cm Counter Battens - Protection Of The Roof Structure With A Fire Retardant ) - Execution Of Chimney Caps From Osb Boards And Coated Sheet Thickness. 0.5-0.7 Mm Color Ral7023 Attic Insulation With Two Layers Of Mineral Wool - Mineral Wool On Rafters With An Aluminum Layer With A Diffusion Fabric Of Λ≤0.026, Thickness. 14 Cm - Mineral Wool Between The Rafters With Λ≤0.038, Thickness 14 Cm - Finishing The Unused Attic Room With Osb Board, Thickness. 10 Mm Installation Of Roof Windows With The Function Of A Roof Hatch X 2 Pcs. - Installation Of Roof Windows X 2 Pcs. - Installation Of Attic Stairs To The Room 3.01 - Execution Of Flashings Made Of Coated Sheet Metal Thickness. 0.5 ÷ 0.7 Color Ral 7023 - Flashings For The Roof And Terraces - Roof Covering With Modular Tile-Like Sheet Ncs S 04500/S 5000 With Roof Communication System (Chimney Benches And Steps) - Execution Of Tiles Made Of Sheet Metal Ncs S 04500/ S 5000 Replacement Of Window Joinery With Pvc Windows With Air Vents, Triple-Glazed With Anti-Burglary Glass P2÷P3 - From The Outside In Ral 7023/7024, From The Inside In Ral 9010 - Installation Of External Window Sills Made Of Galvanized Steel Coated With A Thickness Of 0.5÷0.7 Mm Color Ral 7023 - Installation Of Internal Window Sills Made Of Mdf/Pvc, Th. Min. 25 Mm, Color Ral 9010-White Replacement Of External Doors With Aluminum Profile Doors With Additional Lighting And A Self-Closing System Ral 7023 Color Replacement Of External Doors With Anti-Panic Doors On Level -1 Finishing Internal Flashings After Installation Of Window And Door Woodwork (Including Puttying, Assembly Of Corners, Painting) - Repair Of Cracks In The Walls. - Insulation Of Basement Walls With Thermal Insulation (Polystyrene Λ≤ 0.0026) 12 Cm Thick And Waterproofing - Insulation Of External Walls Of The Building With Thermal Insulation (Polystyrene Λ≤ 0.036) 16 Cm Thick With The Installation Of Thermodoubles - Insulation Of Window Frames 2-3 Cm - Execution Of Facade Plaster Made Of Mineral Plaster 1.5 Mm - Colors According To The Specification In The Design And Elevation Drawings - Execution Of Lighting Of Basement Windows - Installation Of Three Glass Canopies Made Of 8.8.3 Esg Glass /Vsg Colorless With Lashings From Bars 10 Mm With Steel Brackets - Galvanized, Th. 8 Mm Fastened To The Walls Of The Building With M10 Glued Anchors - Disassembly And Assembly Of The Roof Over The Entrance To The Basement Rooms (Level -1) Along With Its Renewal - Repair Of Terraces And Stairs - Waterproofing And Thermal Insulation With Flashings And Laying Frost-Resistant Tiles - Execution Of The Band Around The Building Made Of Concrete Cubes Gr. 6 Cm, And Pebbles Diam. 16 ÷32 Mm Installation Of Titanium-Zinc Gutters 150 Mm And Titanium-Zinc Downpipes  120 Mm, Color Ncs S 4500/S 3000 Replacement Of Powder-Coated Railings, H= 110 Cm, Color Ncs S 4500/S 5000 - Cleaning And Painting Of Railings Along The Driveway For People With Reduced Mobility, Color Ncs S 4500/S 5000 - Execution Of Mosaic Plaster, Thickness ≤ 1.5 Mm, On The Basement Walls To The Plinth Height, Around The Entire Perimeter Of The Building Ncs S 4500/S 5000 - Replacement Of External Lamps With Led Type. - Double Painting And Preparation Of The Base For Painting The Walls Inside The Building - First Floor - Installation Of Lighting Fixtures At The Entrances To The Building - Installation Of Nesting Boxes For Swifts - 6 Pcs. - Installation Of Bat Shelters - 4 Pcs. 2) Ventilation And Electrical Installation - Execution Transfer Grilles In The Existing Door Leaves, Along With Securing The Openings With A Plastic Element - Installation Of Two Duct Exhaust Fans Mounted In The Attic - Execution Of Two Systems (Common Ventilation And Exhaust From The Toilets) - Ventilation Ducts Made Of Galvanized Steel Sheet With A 30 Mm Thick Mineral Wool Lagging, In The Attic The Lagging Is 30 Mm Thick. 50 Mm With Airtightness Class C, Enclosed With Plasterboard - Execution Of Passages Through Partitions, Casings And Suspensions Of Ventilation Ducts, Covering Openings After Existing Ventilation Ducts - Installation Of Diffusers On Level +3 And Ventilation Grilles On Other Levels - Making Inspection Openings In Ceilings - Execution Exhaust Openings In The Roofing - Installation Of A Separate Cooling System For The Server Room With A Freon Pipeline And An Air Conditioner Mounted On The Roof Of The Building - Execution Of The Electrical Installation For Supplying Fans And The Air Conditioner With Surface-Mounted Cables - Extension Of The Existing Switchgear With Three Protection Devices
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
f7fd5af5-64dc-41f1-b20d-dca114f0a707.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders