GTR 60599141
Tenders are invited for Delivery Of 2 Ultrasound Machines With Heads For The Equipment Of The Urology Clinic And The Department Of Anaesthesiology And Intensive Care
ICB — International Competitive Bid
Closed
Central Europe
Tender Information
GTR Reference
60599141
Tendering Authority
Subscribe to view
Tender No
Zp/8/TP/23
Financer Name
Self-Funded
Work Title
Tenders are invited for Delivery Of 2 Ultrasound Machines With Heads For The Equipment Of The Urology Clinic And The Department Of Anaesthesiology And Intensive Care
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
20-02-2023
Closed
Work Detail
The Subject Of The Order Is The Delivery Of 2 Ultrasound Machines With Probes For The Equipment Of The Urology Clinic And The Department Of Anaesthesiology And Intensive Care. L. P. Parameter Name Value Required Scor1. Full Name Of The Ultrasound Machine Specify Not Applicable2. Manufacturer Specify Not Applicable3. Country Specify N/A4. Distributor - Bidder Specify Not Applicable5. Brand New Device Yes 6. Year Of Manufacture Of The Device 2021 Or 2022 7. Device Introduced For Sale Not Earlier Than In 2021 Yes Design8. Clinical, Digital, Premium Color Doppler Ultrasound Machine. Yes 9. Digital Converter Min. 14-Bit 14-Bit - 0 Points>14-Bit - 2.5 Points10. Digital Ultrasonic Beam Forming System Yes 11. Number Of Independent Active Processing Channels Min. 2,000,000 2,000,000 - 0 Points>2,000,000 - 2.5 Points12. Number Of Active Image Head Sockets Min. 3 13. System Dynamics Min. 270 Db 270 Db – 0 Points>270 Db – 2.5 Points14. Lcd Monitor With A Resolution Of Min. 1920 X 1080 Non-Interlaced. Screen Diagonal Min. 21 Inches 15. Camera Console Movable In Two Planes: Up-Down, Left-Right Yes 16. Touch, Programmable Lcd Control Panel Built Into The Console Diagonal Min. 10 Inches 17. Operating Frequency Range Min. 2 Mhz To 20 Mhz. 2 - 20 Mhz - 0 Pts>20 Mhz - 2.5 Pts18. Number Of Dynamic Memory Images (So-Called Cineloop) Min. 12,000 Images 12,000 - 0 Pts>12,000 - 2.5 Pts19. The Ability To Adjust The Playback Speed In The Dynamic Memory Loop Of Images (So-Called Cineloop) Yes 20. The Ability To Obtain Cineloop Sequences In 4B Mode, I.E. 4 Independent Cineloop Sequences Simultaneously On One Image Yes 21. Adjustment Of The Depth Of The Imaging Field Min. 2 - 40 Cm 22. Quantity User-Programmable Presets Min. 50 23. Wheel Base With Four Rotating Wheels Yes 24. Gel Heater Yes Imaging And Image Presentation25. Combinations Of Images Presented Simultaneously. Min.• B, B + B, 4 B• M• B + M• D• B + D• B + C (Color Doppler)• B + Pd (Power Doppler)• 4 B (Color Doppler)• 4 B ( Power Doppler)• B + Color + M Yes 26. Frame Rate For B Mode Min. 1000 Images/S 1000 Images/S - 0 Pts>1000 Images/S - 2.5 Pts Frame Rate B+Color (Cd) Min. 300 Fps 300 Fps - 0 Pts >300 Fps - 2.5 Pts 28. Harmonic Imaging Min. 8 Frequency Bands 8 Bands - 0 Pts>8 Bands - 2.5 Pts29. Color Doppler (Cd) Imaging Yes 30. Color Doppler (Cd) Velocity Range Min.: +/- 4.0 M/S 31. Power Doppler (Pd) And Directional Power Doppler Imaging Yes 32. Extended Imaging Color Doppler Mode With Very High Sensitivity And Resolution, With The Ability To Visualize Very Slow Flows In Small Vessels Yes 33. Pulse Doppler Pwd And Hprf Pwd Imaging (High Repetition Rate) Yes 34. Pulse Doppler (Pwd) Speed Range (At Zero Angle Min.: +/- 7.0 M/S 35. Doppler Gate Adjustment Min. 0.5 Mm To 20 Mm 36. Doppler Beam Deflection Min. +/- 30 Degrees 37. Doppler Gate Angle Correction Min. +/- 80 Degrees 38. Automatic Correction Of The Doppler Gate Angle With One Button In The Range Of Min. +/- 80 Degrees 39. Color And Spectral Tissue Doppler Imaging Yes 40. Compound Imaging In The Ultrad Beam System Sounds Sent From Many Angles And With Different Frequencies (So-Called Crossed Ultrasounds) Yes 41. Number Of Beams Forming An Image In Compound Imaging Yes 5 Beams - 0 Points>5 Beams - 2.5 Points42. Imaging System That Sharpens Contours And Reduces Noise Artifacts - Available On All Transducers Yes 43. Triplex Imaging - (B+Cd/Pd + Pwd) Yes 44. Real-Time B+B/Cd (Color/Power Doppler) Simultaneous Imaging Yes 45. Trapezoidal And Rhombic Imaging On Linear Transducers Yes 46. Automatic Optimization Of The B-Image And Doppler Spectrum With One Button Yes 47. Possibility To Change Color Maps In Color Doppler Min. 20 Maps Yes 20 Maps - 0 Points>20 Maps - 2.5 Points48. Ability To Adjust Gain In Real Time And After Freezing Yes Image Archiving49. Internal Data Archiving System (Patient Data, Images, Sequences) With A Hard Disk With A Capacity Of Min. 500 Gb Yes 50. Installed Dicom 3.0 Module Enabling Saving And Sending Images In The Dicom Standard Yes 51. Saving Images In The Following Formats: Dicom, Jpg, Bmp And Tiff And Image Loops (Avi) In The Camera System With The Option Of Exporting To External Media Such As Pendrvie Or Cd/Dvd Yes 52. Possibility Of Simultaneous Recording Of The Image On The Internal Hdd And Pendrive Media And Printing The Image On The Printer. All 3 Actions Available By Pressing One Button Yes 53. The Function Of Hiding Patient Data When Archiving To External Media Yes 54. Possibility To Set The User Authentication Function - Access For Registered Users Yes 55. Black And White Videoprinter Yes 56. Built-In Usb 2.0 Output For Connecting Media Pendrive Type Yes 57. Built-In Ethernet Network Card 10/100 Mbps Yes 58. Possibility To Connect The Camera To Any Pc With A 100 Mbps Network Cable To Send Data (Images, Reports) Yes 59. Dvd Recorder Yes Utility Functions60. Real-Time Image Magnification Min X8 8X - 0Pt9x - 25X - 1Pt>25X - 2.5Pt61. Image Magnification After Freezing Min. X8 8X - 0 Pts 9X - 15X - 1 Pts>15X - 2.5 Pts62. Number Of Measurements Possible In One Image Min. 10 63. Illuminated Control Panel In Min. 2 Colors Yes 64. Automatic Contour Of The Doppler Spectrum And Baseline Shift And Correction Of The Doppler Gate Angle - Available In Real Time And After Freezing Yes 65. Test Reports With The Option Of Saving Reports In The System Tak 66. Full Software For: • Abdominal • Urological Examinations • Small Organs• Vascular• Orthopedic• Pediatric Yes Ultrasound Transducers67. Convex Head, Broadband, With Change Of Operating Frequency. Specify The Type. Yes 68. Operating Frequency Range Min. 1.0 – 5.0 Mhz. 69. Number Of Elements Min. 800 800 Elements - 0 Points>800 Elements - 2.5 Points70. Scanning Angle Min. 70 Degrees 71. Harmonic Imaging Min. 8 Frequency Bands 8 Bands - 0 Pts > 8 Bands - 2.5 Pts72. Broadband Linear Head, With Change Of Operating Frequency. Specify The Type. Yes 73. Operating Frequency Range. Min. 2.0 - 12.0 Mhz 74. Number Of Elements Min. 800,800 Elements - 0 Points>800 Elements - 2.5 Points 75. Scanning Field Width Max. 40 Mm 76. Harmonic Imaging Min. 5 Frequency Bands 77. Trapezoidal Imaging Yes Expandability - Options (Available On The Day Of Submitting The Offer)78. Possibility Of Expanding The System With A Biplane Rectal Transducer Convex/Convex Yes 79. Possibility Of Expanding The System With Imaging Using Contrast Agents Yes Other80. Warranty For The Entire System (Camera, Heads, Printer) - Min. 2 Years Yes 2 Years - 0 Points 3 Years - 2.5 Points 81. Integration Of The Device With The Existing System Of The Ordering Party Ris/Pacs - Cost On The Contractors Side Yes 82. Users Manual In Polish (Supplied With The Device) Yes 83. Ce Certificate For The Device And Heads (Documents Attached) Yes 84. Manufacturers Authorization For Service And Sale Of The Offered Ultrasound Apparatus In Poland (Attach The Documents). Due To The Constant Access To Original Spare Parts And Consumables (Probes), The Above Provision Regarding The Authorization Of The Service Was Introduced. The Authorized Service Has Access To New Versions Of The Device Software, Which Allows You To Update The System. Yes
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
718e746e-19c7-4104-9bed-741b29d261b2.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.