GTR 59705862
Tenders are invited for Księginice Małe: Construction Of The Volunteer Fire Department (Rfil)
ICB — International Competitive Bid
Closed
Central Europe
Tender Information
GTR Reference
59705862
Tendering Authority
Subscribe to view
Tender No
RIiGK.271.2.2023
Financer Name
Self-Funded
Work Title
Tenders are invited for Księginice Małe: Construction Of The Volunteer Fire Department (Rfil)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Europe
Political Region
European Union
Last Date of Bid Submission
03-02-2023
Closed
Work Detail
Description Of The Subject Of The Order Księginice Małe - Construction Of The Osp Fire Station. 1) Design Works - Including: Taking Over The Authors Supervision By A Designer With Unlimited Licenses In The Architectural Specialty, Ensuring The Participation Of An Architect And Industry Designers (Construction Industry, Sanitary Installations And Electrical Installations) - If Necessary - To Make Changes To The Existing Design Documentation. If Necessary, If It Is Necessary And It Will Result From The Introduced Changes, The Contractor Is Obliged To Obtain A Replacement Building Permit, Including Agreeing The Changes With The Appropriate Fire Protection And Sanitary And Hygienic Experts. Development Of A Photovoltaic Installation Project With A Capacity Of Min. 25 Kw, Development Of A Replacement Design For The Ventilation And Heating Of The Facility. 2) General Construction Works On The Ground Floor Of The Rehability Building (Painting Of All Internal Rooms, Finishing Of Sanitary Rooms - Toilet, Shower, Cloakroom (Moisture Insulation, Tiles, Ceramic Tiles), Floor Finishing With Tiles Ceramic Tiles In All Rooms Except The Garage, - Wall Finishing In Sanitary Rooms With Ceramic Tiles, - Installation Of Handrails On The Stairs Leading To The First Floor, Installation Of Internal Door Frames On The Ground Floor - All Internal Doors On The Ground Floor, - Execution Of Suspended Ceilings In Each Room Of The Ground Floor - Except Garages, Evacuation Signs), Under-Window Ventilators, Details According To The Design Documentation. Once Evacuation, - Installation Of Electric Heaters With A Power Of Min. 2 Kw In Each Room - In The Garage Min. 4 Radiators, In Each Room Min. 1 Heater - With Thermostats, Details According To The Design Documentation. Paddling Pools, Etc. Construction Of Sanitary Sewage Risers, - Installation Of An Internal Hydrant With The Installation From The Place Of Water Entry Into The Building, - Installation Of The Gazex Gas Oxide Detector, - Installation Of Hot Water Flow Heaters, Installation Of An Electric Capacitive Water Heater 140 Liters With Installation, Mechanical Ventilation W4 Mechanically Assisted Gravitational Ventilation In Sanitary And Social Rooms, Details According To The Design Documentation. ), - Construction Of Internal Partition Walls, - Construction Of A Suspended Ceiling Made Of Plasterboards (Together With A Vapor Barrier Foil), - Insulation Of The Attic And Suspended Ceilings With Mineral Wool, - Cladding Of The Roof Structure With Gk-F Boards X 2, - Painting Of Internal Walls And Ceilings - Plastering External And Internal Load-Bearing Walls - From The Inside Of The Building - Finishing Walls And Floors In Sanitary Rooms With Ceramic Tiles, - Assembly Of Internal Door Joinery, - Assembly Of Under-Window Ventilators, - Assembly Of Balustrades At The Stairs - Applies To All Rooms Of The First Floor, Details According To Of The Design Documentation.6) Electrical Works On The First Floor Of The Reservice Building - Execution Of The Electrical Installation (Sockets, Switches, Basic Lighting), - Installation Of An Electric Cooker, - Installation Of The Gazex Gas Monoxide Detector - Emergency And Evacuation Lighting, Applies To All Rooms On The Floor, Details According To The Design Documentation .7) Heel Sanitary Works Rze Of The Remission Building - Assembly Of The Water And Sewage System With All Sanitary Utensils And Accessories, I.E. Toilets, Washbasins, Sinks, Shower Trays, Execution Of Sanitary Sewage Risers, - Assembly Of The Heating System, I.E. 2 Ceiling Fan Coil Units In The Room, Adapted To The Volume Of The Room, Electric Heaters With A Power Of Min. 2 Kw In Each Room With Thermostats, - Installation Of Mechanically Assisted Gravitational Ventilation (See The Previous Note Regarding Changes In Room Ventilation), - Installation Of Hot Water Flow Heaters, Applies To All Rooms On The Floor, Details According To The Design Documentation.8) Other Works: - Preparation Electrical Installation For The Installation Of A Photovoltaic Installation On The Roof Of The Building With A Capacity Of Min. 25 Kw Together With The Design Of The Above-Mentioned Installation And The Assembly Of The Necessary Equipment (Without Photovoltaic Panels) - Assembly Of External Lighting On The Facade.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
dc3ad55a-0c3f-4c2c-9671-02bae82315f9.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.