GTR 59382210

Tenders Are Invited For Design, Supply, Installation And Testing Of Diesel Engine Cooling Line Drain Piping To Fire Water Tank At Srsdm 400Kv Substations

ICB — International Competitive Bid Closed Asia
Tender Information
GTR Reference
59382210
Tendering Authority
Subscribe to view
Tender No
2332300151
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Design, Supply, Installation And Testing Of Diesel Engine Cooling Line Drain Piping To Fire Water Tank At Srsdm 400Kv Substations
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Asia
Political Region
Arab World,Gulf Cooperation Council GCC,Middle East,Middle East and North Africa MENA
Last Date of Bid Submission
18-01-2023 Closed
Work Detail
Quotation Are Invited For Design, Supply, Installation And Testing Of Diesel Engine Cooling Line Drain Piping To Fire Water Tank At Srsdm 400Kv Substations 1032203487Rfx Standard Terms & Conditions 1) Prices Should Be Ddp Delivery Duty Paid At Dewa Stores. 2) Quotation To Be Submitted Only In Local Currency U.A.E Dirhams 3) Dewa Standard Payment Terms Is 30 Days Credit From The Date Of Acceptance Of Material 4) No Dewa Staff Or His Or Her Relatives Up To Third Degree Should Have Ownership Or Partnership In Your Company, And Your Participation In Dewa Tenders / Rfqs Should Not Constitute A Conflict Or Perceived Conflict Of Interest. 1 Item-00001 Design, Supply, Installation And Testing Of Diesel Engine Cooling Line Drain Piping To Fire Water Tank At Srsdm 400Kv Substations. Scope Of Work: 1.#Visit The Site To Acquaint Himself Fully To Assess The Requirement. 2.#Design, Supply, Installation And Testing Of Diesel Engine Cooling Line Drain Piping Extension From Existing Drain Point Inside The Fire Pump Room To Fire Water Tank 3.#Design (Single Line Diagram Only) The Piping Extension From The Available De Cooling Line Drain Piping Inside Fire Pump Room To Fire Water Tank. 4.#Hydraulic Calculation For The Extension Work To Be Submitted For Approval. 5.#The Pipe Size Selection Should Be Up Size Tha N The Existing Cooling Loop And Should Ensure Minimum Flow Rate As Follows: Substation 1 Ea 1 Item-00001 Design, Supply, Installation And Testing Of Diesel Engine Cooling Line Drain Piping To Fire Water Tank At Srsdm 400Kv Substations. Scope Of Work: 1.#Visit The Site To Acquaint Himself Fully To Assess The Requirement. 2.#Design, Supply, Installation And Testing Of Diesel Engine Cooling Line Drain Piping Extension From Existing Drain Point Inside The Fire Pump Room To Fire Water Tank 3.#Design (Single Line Diagram Only) The Piping Extension From The Available De Cooling Line Drain Piping Inside Fire Pump Room To Fire Water Tank. 4.#Hydraulic Calculation For The Extension Work To Be Submitted For Approval. 5.#The Pipe Size Selection Should Be Up Size Tha N The Existing Cooling Loop And Should Ensure Minimum Flow Rate As Follows: Substation 1 Ea Name#Make#Model#Speed#Power#Engine Water Jac Ket Temp Normal Range #Heat Exchanger Min Flow# Srsdm 400 Kv#Clarke#Jw6h-Uf60#2100-2350 Rpm#375-360 Bhp#82-91 Deg C #167 L/Min# N Ote: Actual Heat Exchanger Outlet Flow Rate And Temperature To Be Collected From Oem Data Sheet For The Engine. 6.#Supply All Materi Als Required To Complete The Jobs Incudes Ss Or Gi Pipes (Seamless Sch 40 Factory Galvanized) & Fittings Same As Existing At Site, P Ressure, Temperature Gauges, Flow Meter And Gate Valves. 7.#Contractor To Carry Out Trial Test Prior To Installation With Flexible H Ose To Achieve The Required Flow, Temperature And Pressure As P Er Submitted Design. 8.#Detailed Installation Of The Work, Material T O Be Submitted By The Contractor For Dewa Approval. 9.#Contractor To Propose Site Installations With Optimal Routing And Minimum Fit Tings. 10.#All The Civil And Mechanical Work To Be Included In The Scope Of Work. 11.#Performance Of The Fire Diesel Engine To Be Ve Rified Before And After Testing And Ensure There Is No Deviation 12.#Painting Shall Be Done As Per Paint Manufacturer#S Specificatio N. Two Coat Of Red Oxide And Two Coat Of Gloss Red Paint By Mixing With Proper Ratio Of Base And Curing Agent With Thinner. Exposed Pipe Work Shall Additionally Be Painted One Coat Gloss Red. 1 Special Notes / Instructions: Design, Supply, Installation And Testing Of Diesel Engine Cooling Line Drain Piping To Fire Water Tank At Srsdm 400Kv Substations. Tender Link : Https://Www.Dewa.Gov.Ae/Api/Rfxdownload/2332300151
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
34afb2e0-e127-4550-87cb-1040863c0ce8.pdf
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders