GTR 54939005
Tenders Are Invited For Supply Of Control Measuring Devices And Spare Parts
ICB — International Competitive Bid
Closed
Western Asia
Tender Information
GTR Reference
54939005
Tendering Authority
Subscribe to view
Tender No
32027-22
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Supply Of Control Measuring Devices And Spare Parts
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Western Asia
Political Region
Commonwealth of Independent States CIS
Last Date of Bid Submission
20-09-2022
Closed
Work Detail
Tenders Are Invited For Supply Of Control Measuring Devices And Spare Parts 1. Replaceable Electrochemical Sensor. Measuring Medium - Ammonia (Nh3), Measuring Method - Electrochemical, Error - ±5 Ppm, Protection Protection - Atex, Ex Ii 2 Gd Eex Dla Iic, Response Time - <30 Seconds, Measuring Range 0-200Ppm (From 50 To 200Ppm, 50Ppm), Part Number: -S3ka1ss Iec 60079-0 En 50271 Pie. 35 2. Replaceable Electrochemical Sensor. Measuring Medium - Oxygen (O2), Measuring Method - Electrochemical, Measuring Range 0-25% Volume, Part Number: -S3ko1ss Iec 60079-0 En 50271 Pie. 1 3. Replaceable Catalytic Roller Sensor, Measuring Medium - Hydrogen (H2), Measuring Method - Infrared (Multi-Use Sensor), Error - ±5 %, Protection Protection - Atex, Ex Ii B+H2, Response Time - <60 Sec, Measuring Range 0-100% Lel Part Number: -1226A0359 22 Units Replaceable Electrochemical Sensor Measuring Medium - Hydrogen (H2), Measuring Method - Electrochemical, Enclosure Protection - Atex, Ex Ii 2 Gd Eex Dla Iic Measuring Range - 0-1000Ppm, Part Number: S3kg1ss - 2 Pcs Iec 60079-0 En 50271 Pie. 24 4. Replaceable Electrochemical Sensor Measuring Medium - Hydrogen Sulphide (H2s), Measuring Method - Electrochemical, Enclosure Protection - Atex, Ex Ii 2 Gd Eex Dla Iic , Measuring Range 0-100Ppm (50 To 500Ppm, 10Ppm) Part Number: -S3kh2ss Iec 60079-0 En 50271 Pie. 1 5. Replaceable Electrochemical Sensor. Measuring Medium - Carbon Monoxide (Co), Measuring Method - Electrochemical, Enclosure Protection - Atex, Ex Ii 2 Gd Eex Dla Iic, Measuring Range 0-300Ppm (From 100 To 999Ppm, 100Ppm) Part Number: -S3kc1ss Iec 60079-0 En 50271 Pie. 1 6. Interchangeable Infrared Sensor.Measuring Medium Carbon Dioxide (Co2), Measurement Method Infrared (Multi-Use Sensor), Protection Protection Atex, Ex Ii 2 Gd Eex Dla Iic, Response Time <3 0 Sec, Measuring Range 0- 5% Volume, Part Number: - 1226-0301 Iec 60079-0 En 50271 Pie. 6 7. Replaceable Catalytic Roller Sensor.Measurement Mediummethane Gas (Ch4), Measurement Methodinfrared(Multipurpose Sensor), Error- ±5%, Protection Protection- Atex, Ex Ii B+H2, Response Time- <60 Sec, Measurement Range 0-100% Lel Part Number: -1226A0359 Iec 60079-0 En 50271 Pie. 14 8. Gas Detector Spare Parts (Cover) Part No. S3kcal For Electrochemical Xnx Cartridge Iec 60079-0 En 50271 Pie. 5 6 9. Gas Detector Spare Parts (Cover) Part No. No. 1226A0411 For The Mpd Cartridge Iec 60079-0 En 50271 Pie. 5 10. Gas Detector Spare Parts (Mouthpiece) Part #02000-A-1640 For The Mpd Cartridge Iec 60079-0 En 50271 Pie. 5 11. Gas Detector Accessory Magnetic Drill Part # 1226-0254 Iec 60079-0 En 50271 Pie. 10 12. Gas Detector Accessory, Calibration Tube Part No. Sppptub 1 Meter Iec 60079-0 En 50271 Pie. 10 13. Lubricating Oil For Increasing The Sensitivity Of Ultrasonic Flowmeters (Tubular) Temperature Range: Tmax 200 ºc Krohne Part No. X380030100 Iso 17089-2:2012 Pie. 3 14. Sick Filter For Dust Analyzer Changeable Filter Of The Analyzer That Determines The Concentration Of Dust Emitted From The Chimney Of The Granulator Name: Filter Element Micro-Topelement C1140 P/N : 5306091, En 14181:2014 Pie. 5 15. Ph Sensor: Model: Inpro3250 (I); Sensor Length: 120 Mm Joint Type: Ceramic Joint Measuring Range: 0-14 Ph Case Material: Glass Tish: 0÷100 °C, Pish: 0÷4 Bar Cable Connection: K8s; Process Connection: Pg 13.5 Threaded Order No. 52005373 Iec 60079-0 Pie. 5 16. Ph Sensor: Model: Inpro4260 (I); Sensor Length: 120 Mm Joint Type: Ceramic Joint Measuring Range: 0-14 Ph Case Material: Glass Tish: 0÷130 °C, Pish: 0÷15 Bar Cable Connection: K8s; Process Connection: Pg 13.5 Threaded Order No. 52005381 Iec 60079-0 Pie. 5 17. Vibration Transducer Measuring Range: 0-20 Mm/Sec Frequency Range: 2 Hz÷1Khz Output Signal: 4-20Ma Power Supply: 12-32 V (Constant) Temperature Range: -25÷+90 °C Material: Alsl 316L Degree Of Protection: Ip 67 Fixing (Mounting) Screw: ¼-28 Unf (External Thread) -- M8x1.25 (External Thread) Connecting Cable: Armored, Ptfe, L=15 Meters Dimensions (Cylindrical): Ø 27Mm, Height =43 Mm Ambient: -15÷ +55 °C Part No. Mtn/ 1185Ic+20+Ms067 It Measures The Vibration Of The Fan (Fan) In The Cooling Water System (Gradirni). Iso 10817-1 Iso 2954 Iec 60529 Pie. 3 18. Indicator Bimetallic Thermometer With Protective Sleeve, Size Limit: -30÷70 °C Tishchi: 39 °C Pishchi: 2.5 Kgf/Cm2 En13190:2002 Iec 60529 Pie. 2 7 Accuracy Class: 1.0% Medium: Liquid Diameter Of Thermoball: 6.6Mm Degree Of Protection: Ip 65 Thermocouple Length (Immersion Depth): 250 Mm Thermocouple Connection Size: ½ Npt (M) Process Connection: 1 ½ Diameter Of Sphere: 160 Mm, Material Of Sphere: Glass Case Material: Stainless Steel Along With Promotional Tag -30-Tg-4306 19. Indicator Bimetallic Thermometer With Protective Sleeve, Size Limit: -30÷70 °C Tishchi: 39 °C Pishchi: 2.5 Kgf/Cm2 Accuracy Class: 1.0% Medium: Liquid Diameter Of Thermoball: 6.6Mm Degree Of Protection: Ip 65 Thermocouple Length (Immersion Depth): 350 Mm Thermocouple Connection Size: ½ Npt (M) Process Connection: 1 ½ Ball Diameter: 160 Mm, Ball Material: Glass Case Material: Stainless Steel Along With Promotional Tag -30-Tg-4308 En13190:2002 Iec 60529 Pie. 2 20. Bi-Metal Thermometer 0-100 °C Indicator Bimetallic Thermometer With Protective Sleeve, Measuring Range: 0÷100 °C Tooth: 80 °C Pishchi: 2.5 Kgf/Cm2 Accuracy Class: 1.0% Medium: Liquid Diameter Of Thermoball: 6 Mm Degree Of Protection: Ip 65 Thermocouple Length (Immersion Depth): 240 Mm Thermocouple Connection Size: ½ Npt (M) Process Connection: 1 ½ Ball Diameter: 160 Mm, Ball Material: Glass Case Material: Stainless Steel With Promotional Tag -10-Tg-4508, 10-Tg-4509 Part No. 160 Am 040 E 340 Nh Sg En13190:2002 Pie. 4 21. Temperature Element 0-700 °C Temperature Element Type: K-Type Thermocouple Tishchi: 0÷700ºc Terminal Connection: Duplex (Double (4-Wire) Element Connection Size: ½ Npt (M) Material: Stainless Steel 316Ss Element Immersion Depth: 400 Mm Coating: Magnesium Oxide Element Diameter (Outer Diameter): 6 Mm Iec 60529 Iec 61326-2-3 Iec 60079-0 Iec 600751 Pie. 5 22. Glass Level Indicator 0-100 % Glass Level Gauge, Magnetic, With Reverse Flange Process Connection: Flange Ansi 2 150# Medium - Liquid (Naocl-Sodium Hypochlorite) Case Material: Ss316l+Teflon Coated Tooth: 20 °C Visible Part: 2670 Mm Center To Center: 2400 Mm Specific Density -1200 Kg/M3 Iso 4266-3 Pie. 1 8 Visually Indicates The Level In The Chemical Storage Tank. Part No. D-150 Along With Promotional Tag -30-Lg-2531 23. Glass Level Indicator 0-100 % Glass Level Gauge, Magnetic, With Reverse Flange Process Connection: Flange Ansi 1 "150# Environment - Liquid (Anti-Corrosion Agent - Inhibitor (3Dt129)) Case Material: Ss316l+Teflon Coated Tooth: 20 °C Visible Part: 1598 Mm Center-To-Center: 1288 Mm Specific Density -1370 Kg/M3 Visually Indicates The Level In The Chemical Storage Tank. Part No. D-150 Along With Promotional Tag -30-Lg-2534 Iso 4266-3 Pie. 1 24. Level Indicator 0-100 % Glass Level Gauge With Counter Flange Process Connection: Flange 1 "Ansi 600 Rf Working Medium: Water/Steam Size Range: 0-100 % Pishchi: 47.7 Kg /Cm2 Toothpick = 262 °C Distance From Center To Center: 847 Mm Visible Part Distance:677 Part No. Bc33 2X9+9 G42.1.42 It Measures The Level Of Steam Capacity In The Boiler Room With Promotional Tag -30-Lg-4551, 30-Lg-4651, 30-Lg4751,30-Lg-4552, 30-Lg-4652, 30-Lg-4752 Iso 4266-3:2002, Iso 4266-1:2002 Pie. 6 25. Level Indicator 0-100 % Glass Level Gauge With Counter Flange Process Connection: Flange 1 "Ansi 600 Rf Working Medium: Water/Steam Size Range: 0-100 % Pishchi: 47.7 Kg /Cm2 Toothpick = 262 °C Distance From Center To Center: 770 Mm Visible Distance: 650 Mm Part No. Bc33 2X9+9 G42.1.42 Together With Rlg (With Resistive Level Gauge) Determines Both The Water And Steam Levels Of The Steam Capacity In The Boiler Room (Hydrastep System) With Promotional Tag -30-Lg-4555, 30-Lg-4655, 30-Lg4755 Iso 4266-3:2002, Iso 4266-1:2002 Pie. 3 26. Explosion-Proof Resistance Thermocouple Measurement Range: 0÷100°C, Temperature: 0÷30 °C Sensor Type: Pt100 (-200÷600 °C) Number Of Sensors: Duplex Number Of Wires: 4 Thermocouple Throat Length: 80Mm Thermocouple: Outer Diameter: 6Mm Sleeve Outer Diameter: 9Mm Case Material: Stainless Steel Output Signal: 4÷20 Ma (Hart Protocol) Working Medium: Liquid Immersion Depth: 160 Mm Material: Stainless Steel Process Connection: ½ Npt En 14597:2012 Iec 60529 Iec 61508-1 Pie. 2 9 Cable Entry: M20x1.5 Degree Of Protection: Ip68; Ex Ia Iic T6 The Chemical Solution (Naoh) Measures The Temperature In The Storage Tank And Transmits The Signal. Part No. Tr10-Bba1cdsdkt00b Along With Promotional Tag -30-Tt-3512 27. Pressure Relay Pressure Adjustment Range: -0.5-45 Bar Power Supply: 250 Volts (Variable), 6A, Contact: Spst-No (Single Pole Single Position Contact, Normally Open) Temperature: -55 ÷135 °C Degree Of Protection: Ip 65 Cable Length: 2.5 M Joining The Process; 1/4" Part No. Acb-2Ua466w It Detects A Low Value Of The Pressure At The Outlet Of The Compressor In The Ventilation System. Iec 60529 En 12263 Pie. 2 28. Pressure Difference Transducer Measuring Range: -623÷623 Mbar Type: Coplanar Output Signal: 4÷20 Ma (Hart Protocol) Power Supply: 24 V (Constant) Accuracy: +/- 0.2% Working Medium: Gas/Vapor/Liquid Ambient = -15÷+55 °C Screen: Lcd Process Connection: 3 Valve Blocks Cable Entry: 2 Pcs M20x1.5 Material: 316Lsst Degree Of Protection: Ip66; Ex Ia Iic T4 Certificate: Sil2 Iec 60079-0 Iec 61508-1 Iec 60529 Iec 61326-2-3 Pie. 6 29. Pressure Transducer Measuring Range: -1÷276 Bar Output Signal: 4÷20 Ma (Hart Protocol) Power Supply: 24 V (Constant) Accuracy: +/- 0.2% Working Medi Tender Link : Https://Www.Socar.Az/Socar/Assets/Documents/En/Procurement-Notices/01.09.2022-32027-22-Purpose%20Of%20Control%20Measuring%20Devices%20And%20Spare%20Parts.Docx
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
a47bdf04-3e9b-40a9-af5c-502f6b3bdc4a.pdf
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.