GTR 50359881
Tenders Are Invited For Development Of Meeting Space For Policy And Public Groups - 266 Graham Avenue
ICB — International Competitive Bid
Closed
Northern America
Tender Information
GTR Reference
50359881
Tendering Authority
Subscribe to view
Tender No
0000221529
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Development Of Meeting Space For Policy And Public Groups - 266 Graham Avenue
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Northern America
Political Region
Asia Pacific Economic Cooperation APEC,G20
Last Date of Bid Submission
16-05-2022
Closed
Work Detail
Development Of Meeting Space For Policy And Public Groups - 266 Graham Avenue - D2.&Nbsp;&Nbsp;&Nbsp;&Nbsp;&Nbsp;&Nbsp;&Nbsp;&Nbsp;&Nbsp; Scope Of Work D2.1&Nbsp;&Nbsp;&Nbsp;&Nbsp;&Nbsp;&Nbsp;&Nbsp; The Work To Be Done Under The Contract Shall Consist Of Interior Renovation To Create Winnipeg Police Service Meeting Space At 266 Graham Avenue As Per Drawings And Specifications. D2.2&Nbsp;&Nbsp;&Nbsp;&Nbsp;&Nbsp;&Nbsp;&Nbsp; The Major Components Of The Work Are As Follows: (A)&Nbsp;&Nbsp; Demolition Of The Following Items: (I)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Existing Architectural Components, Including But Not Limited To Wall Partitions, Doors, Sidelights, Flooring Materials; (Ii)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Miscellaneous Specialties, Including But Not Limited To Shelving And Brackets, Wall- Mounted Dispensers, Whiteboards, Corner Guards, Other Wall-Mounted Items; (Iii)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Removal And Disconnection Of Existing Electrical Components, Including But Not Limited To All Components With Designation ‘D’ Back To The Source, Electric Baseboard Heaters, Thermostat. (Iv)&Nbsp;&Nbsp;&Nbsp;&Nbsp; The Removal Of The Existing Ceiling, Hvac System And Lighting Will Be Completed By The Abatement Contractors Prior To The Start Of Work Associated With Bid Opportunity 1174-2018. (B)&Nbsp;&Nbsp; Renovation To Include The Installation Of: (I)&Nbsp;&Nbsp;&Nbsp;&Nbsp; New Architectural Components, Including But Not Limited To Wall Partitions, Doors, Glazing, Raised Access Flooring, Other Flooring Materials, Ramps, Power Door Operators, Millwork, Painting; (Ii)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Miscellaneous Specialties, Including But Not Limited To Television Mounts, Corner Guards, Bumpers, Paper Towel Dispenser; (Iii)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Re-Installation And Connection Of Existing Electronic Projector Screen; (Iv)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Electrical Components, Including But Not Limited To Card Swipe Access, Power And Supply, Wiring, Telecommunications, Data Terminations, Power Door Operators, Lighting, Exit Signs; (V)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Mechanical Components, Including But Not Limited To Plumbing Fixtures, Ventilation Systems, Fire Protection System; (Vi)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Testing And Balancing, Including But Not Limited To Ventilation Systems, Fire Protection System, Network Cabling. (C)&Nbsp;&Nbsp;&Nbsp; Construction Activities Shall Be Conducted In Such A Manner That The Maximum Sound Levels Will Not Exceed 80 Dba Between 7:30 H And 17:00 H.&Nbsp; Work That Exceeds The Maximum Sound Level Are To Be Completed After Office Hours.&Nbsp; Other Work Restrictions Will Be Coordinated To The Contractor.&Nbsp;&Nbsp;Weekend And Evening Work Hours Are Unrestricted. (I)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Work That Is Restricted During Day Time, Including But Not Limited To: (I)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Hammer Drilling (Ii)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Jackhammering (Iii)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Concrete Saw Cutting (D)&Nbsp;&Nbsp; Contractor Is Required To Ensure That The Building Is Secure At All Times.&Nbsp; This Includes: (I)&Nbsp;&Nbsp;&Nbsp;&Nbsp; The Exterior Room 203 Of The Building.&Nbsp; Contractor Shall Coordinate With Contract Administrator For Additional Security Should The Exterior Perimeter Need To Be Breached Due To Renovation Activities. (Ii)&Nbsp;&Nbsp;&Nbsp;&Nbsp; The Interior Of The Council Building.&Nbsp; Contractor Shall Ensure That Any Rooms That Are Accessed For The Purposes Of Their Work Be Monitored During Use And Secured After Work Is Completed. (Iii)&Nbsp;&Nbsp;&Nbsp;&Nbsp; The Worksite.&Nbsp; Contractor Shall Ensure That The Worksite Is Secure At All Times. (E)&Nbsp;&Nbsp; Contractor Is To Ensure That Construction Dust And Debris Are Contained Within The Area Of Work By Use Of Sticky Mats That Shall Be Changed Daily And Other Control Measures, As Required. (F)&Nbsp;&Nbsp;&Nbsp; Existing Smoke/Heat Detectors In The Room 203 Shall Be Protected And Wrapped Accordingly, And Disabled, As Required. (G)&Nbsp;&Nbsp; Contractor To Provide Outmost Cares And Protections Of All Existing Serviceable Mechanical/Electrical/Telecommunication Network Systems And Adjacent Building Parts To Prevent Damages During The Performance Of Work And Other Related Activities.&Nbsp; Any Damages Will Be The Responsibility Of The Contractor. (H)&Nbsp;&Nbsp; Contractor To Ensure That All Flooring In The Path Of Delivery From The Entrance Of 266 Graham Avenue To The Worksite Is Protected When Delivering Equipment And/Or Materials To The Work Site. (I)&Nbsp;&Nbsp;&Nbsp;&Nbsp; Contractor Shall Protect Existing Glass Wall Located Between Corridor And Room 203 From Damage, Dust, Scratches And Cracks. &Nbsp;
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
9bd8c5cf-becd-4ff7-8290-a1a1b616ccde.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.