Tenders Are Invited For Supply Of Ultrasound Equipment

Tender Detail

36408592
Self Funded
Tenders Are Invited For Supply Of Ultrasound Equipment
ICB
Western Asia
Arab World,Gulf Cooperation Council, GCC,Middle East,Middle East and North Africa, MENA
15-02-2021

Work Detail

Quotation Are Invited For Supply Of 9 Units Ultrasound Equipment Completion Of The Compliance Sheet Is Mandatory Please Do Not Leave Gaps Answer Clearly And Succinctly And Please Reference The Compliance Statements With Your Accompanying Material All The Information To Be Provided By The Supplier In The Compliance Sheet Must Be 100 Correct Accurate Any False Information Given Will Result In An Immediate Disqualification And The Offer Shall Be Considered Null And Void Complete Separate Specification Forms For Each Product Offered Even If It Is Different Models From Same The Manufacturer Also Clearly Indicate On Specification Form Which Product The Specifications Match Sidra Requires A Comprehensive Submittal And Needs To Be Made Aware Of All Additional Options And Accessories Please Include This Information In The Submission The Order Of Presentation For Consideration Is The Basic Device Offered Followed By Options And Then Accessories Operation And Service Manuals All Service And Operator Manuals Must Be Supplied In Both Hard And Soft Copies 2 Of Each For All Equipment All Hard Copies Must Be Original Manuals And Not Copies Except As Approved On A Case By Case Basis Mandatory Pre Qualification Questions Generic SpecificationRequirements Met Yes No Comments Reference In SubmissionDevice Must Represent The Most Current Technology And Comply With The Latest Standards Of Care Device Must Be Ce Fda Or Csa Approved Must Be Provided With The Ecri 5 Digit Device Code And The 6 Digit Manufacturer Code Power Supply Must Comply With Sidras Standard Voltage Supply Single Phase 240V 6 225V 255V 50 Hz 1 Hz Utilizing A Three Pin British Style Electrical Plug Or Double Insulated Ac Power Supply Adaptor And As Applicable A Rechargeable Battery Source For Sensitive Analyzers And Other Equipments As Designated A Standalone Ups Must Be Provided With The AnalyzerIf A Higher Voltages Are Required The Only Alternate Is A 415V 6 390V 440 Three Phase Power Supply Must Be Able To Be Delivered And Installed Using Regular Egress And Exit Points In The Facility Must Be Able To Be Transported To End User Site Using Regular Door Access 1060Mm Wide And 2080 High Lift Access Must Not Exceed 3000 Kgs Or Be Greater Than 2560Mm X 1395Mm X 2970Mm Hxwxd Please Notify If Offer Exceeds Any Of These Parameters Must Be Able To Be Decontaminated By Washing Wiping Disinfecting Using Internationally Acceptable Decontamination Processes Must State Model Year Of Introduction Spare Parts Availability After End Of Sales In Years And Any Planned End Of Manufacturing Date Mandatory Functional And Performance Specifications Requirements Met Yes No Comments Reference In SubmissionClinical Applications Abdomen Abdominal Vascular Urology Ob Gyn Neonatal Brain Small Parts Breast Thyroid Scrotal Prostate Msk Probe Types MhzFlat Linear Array 5 10Convex Array 2 5 5Microconvex Array 4 8Phased Sector Vector Array 2 4Endovaginal 5 9Endorectal 5 9 Hockey Stick Probe 8 18Linear Probe 9 16Scan ModesB Mode 2 D Contrast Harmonic ImagingTissue Harmonic ImagingM ModeDopplerColor Doppler Imaging Cdi Power Doppler Imaging Continuous Wave Pulsed Wave Duplex Triplex Elastography Needle Enhancement Mode CapabilityImage Display And ProcessingAutomated Image OptimizationGrayscale Levels 256Image Magnification Zoom Monitor Cm In 38 15 Split Screen Maximum Display Depth Mm 240PreprocessingPostprocessingDigital Image StorageCine Loop Playback Digital Storage Hard Drive Size 120 GbSoftware FeaturesAnalysis Packages Structured ReportsDigital Calipers Distance Area VolumeExam Presets On Screen AnnotationConnectivity Data Export Methods Ethernet WirelessExported Still Image Formats Jpeg DicomExported Video Clip Formats Mp4 Avi Mov Dicom 3 0 CompliantOther SpecificationsDigital And Tv Video OutputsFull Screen Annotation Preferred Functional And Performance Specifications Requirements Met Yes No Comments Reference In SubmissionWireless Data Export FunctionBelow Probes And Scan Modes Should Be Offered As An Optional Features With Indivisual PriceDedicated 3 D 4 D Probe 3 D Freehand 3 D Automatic 4 D Automatic Color Doppler Imaging Cdi 3D 4DPower Doppler Imaging 3D 4DCerner Emr Pearl Requirements Requirements Met Yes No Comments Reference In SubmissionDoes A Cerner Driver Interface Exist For This Device Interface Specifications Which Show The Communication Protocol Format Of Data And The Connectivity Method To Get This Data Together With The Details Of The Connectivity Port If Hl7 Protocol Is Used By The Device Please Provide A Sample Hl7 MessageIf Hl7 Protocol Not Used Provide The Technical And Discrete Data Elements For IntegrationConfiguration Information For Data Ports Including But Not Limited To Baud Rate Parity Stop Bit And Data Bit For Rs232 Connection Tcp Ip Configuration For Ethernet Connections The Supplier Must Provide Details On The Pin Configuration For Serial Ports Data Port Adapters Serial Interfaces Required To Convert Any Proprietary Data Port To An Rs232 Connection Identification Of Any Additional Hardware Requirements To Enable Full Integration And Operation I E Servers Licenses Dongles Wi Fi Communication Devices Etc Etc Interface Specifications Which Show The Communication Protocol Format Of Data And The Connectivity Method To Get This Data Together With The Details Of The Connectivity Port Any Other User Documentation For The Configuration Of The Device And Operation That May Assist Sidra To Set The Device Up For Interfacing And May Also Describe The Functionality To Help Us Test That Device Assistance To Investigate And Correct Any Issues With Connectivity And Must Be Available To Help With Configuration For All Data Connectivity Settings Details Of Technical Integration Training Required For Hospital Staff Must Comply With Sidras Enterprise Architecture And Security Policy It Section Has An Mds2 Questioner Form Been Filled Out And Reviewed With Clinical Systems Manager And It Security Manager If Not Please Contact Bme Pre Procument To Obtain The Required Mds2 Questioner Form Accessories Spare Parts Consumables Hardware And Software OptionsRequirements Met Yes No Comments Reference In SubmissionInclude All Standard Consumables Accessories For Initial Testing And Operation Commissioning Provide List Of Manufacturer Recommended Spare Parts With Pricing Within The Proposal Provide An Electronic Catalogue Of All Available Accessories Spare Parts Consumables Hardware And Software Options As Applicable Must Be Supplied With User Defined Quantity And Range Of Consumables For Training And Validation As Applicable All Phantoms Test Jigs Calibration Boxes Accessories And Simulators Required For Pm Repairs And End User Daily Weekly Checks Must Be Included If Applicable Must Include Details And Pricing For Licenses Related To Software And Operation Identify If These Are Concurrent Or Single User Mandatory Warranty Requirements Met Yes No Comments Reference In SubmissionWarranty Period Is At Least Two Years Of Full Service Including Parts And Labor And Will Start At Go Live Or The First Time The Device System Used For Patient Care The Vendor Acknowledges The Warranty Cannot Commence Until Installation Testing Commissioning Integegration And Hand Over Is Completed At Sidra Hospitals Site And If The Installation At Sidra Hospital Site Is Delayed This Will Not Activate The Warranty Until The Device Has Been Handed Over As Stated During Warranty Period All Preventive Maintenance Should Be Vendor Responsibilty Covers All Pm Kits Accessories And Unlimited Emergency Breakdown Calls It Should Include All Software Updates Foc During Warranty Period Mandatory Facilities And Safety Requirements Met Yes No Comments Reference In SubmissionVendor May Be Requested To Perform A Site Survey At No Cost To The Customer Upon Request If Required Site Survey To Identify All Installation Requirements Before Submission Of Formal Offer All Equipment Must Be Installed By The Manufacturers Authorized Representatives Vendor Must Notify At Time Of Offer If The Devices Or Components Require Special Installation Requirements Special Delivery Requirements Special Handling Bulky Package Specific Handling Requirements Etc Contains Any Hazardous Materials Chemicals All Vendors Must Undertake To Retrieve And Process The Device At The End Of Its Useful Life Power Requirements Voltage Current Watts Btu Hr Weight Dimensions H Xwxd

Key Value

Tender Value
Refer document
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail