Indefinite Delivery Petroleum Lt Oils And Lubrication Pol Architect Engineer Contract Primarily Various Locations Alaska W911kb20r0010

Tender Detail

29381897
W911KB 20 R 0010
Self Funded
Indefinite Delivery Petroleum Lt Oils And Lubrication Pol Architect Engineer Contract Primarily Various Locations Alaska W911kb20r0010
ICB
Northern America
Asia-Pacific Economic Cooperation, APEC,G20
30-04-2020

Work Detail

View Changes C Indefinite Delivery Architect Engineer Services Contract For Pol Petroleum Oils And Lubricants Systems And Related Projects Primarily Various Locations Alaska General Information Document Type Synopsis Solicitation Solicitation Number W911kb 20 R 0010 Posted Date 27 February 2020 Original Response Date 31 March 2020 Amended Response Date 29 April 2020 Original Archive Date Current Archive Date Classification Code C Architect And Engineering Services Set Aside Total Small Business Contracting Office Address Us Army Corp Of Engineers Alaska Cepoa Ct P O Box 6898 Jber Ak 99506 0898 1 Contract Information An Indefinite Delivery Contract Is Being Procured In Accordance With The Brooks A E Act As Implemented In Far Subpart 36 6 Firms Will Be Selected For Negotiation Based On Demonstrated Competence And Qualifications For The Required Work North American Industrial Classification System Code Is 541330 Which Has A Size Standard Of 16 500 000 In Average Annual Receipts To Receive Award Contractors Must Be Registered In The System For Award Management Sam Register Via The Sam Internet Site At Https Www Sam Gov This Announcement Is Set Aside For Small Business Firms The Contract Shall Be An Indefinite Delivery Firm Fixed Price With A Contract Limit Of 6 000 000 With A Base Term Of Five Years There Is No Specific Task Order Limit Except The Limit Of The Contract Award Of One Contract Is Anticipated For The 3Rd Quarter Of Fy 2020 All Responders Are Advised That This Contract May Be Revised Or Canceled At Any Time During The Solicitation Selection Evaluation Negotiation And Final Award In Addition No Projects Are Yet Authorized See Far 52 232 18 This Solicitation Does Not Guarantee Work To The Selected Firm Telephonic Interviews Will Be Held With All Of The Most Highly Qualified Firms 2 Project Information The Ae Selected Would Be Required To Have Sufficient Staff Flexibility And Capability To Be Available On An As Needed Basis Typical Types Of Services To Be Provided May Include Projects Primarily Involved In The Inspection Maintenance Repair Upgrade Or Alteration Of Existing Pol Storage Facilities Distribution Systems Pol Support Facilities And Infrastructure Projects May Also Include Design Of New Pol Related Facilities Work Includes A E Services Site Surveys Facility Inspections Preparation For And Participation In Design Charrettes Technical Review Preparation Of Plans Specifications Design Analysis Design Build Rfps Programming Studies Dd Form 1391 Development Construction Support Services And Cost Estimates For Solicitation Of Construction For Repair Renovation New Construction Projects Or Engineering Studies Firms Must Have Primary Capability In Pol Design And Engineering And Should Be Aware Of Or Capable Of Acquiring Knowledge Of Design Requirements And Procedures Set Forth By The Defense Logistics Agency Defense Energy Support Center Desc Sustainment Restoration And Modernization Srm Program Renovations Might Include Fire Protection Upgrades Afff Fuel Containment Transport Delivery Storage And Dispensing Systems As Well As Conversion Of Fuel Type Services Incidental To The Overall Project May Also Require Api 653 Tank Inspection Piping System Evaluation In Accordance With Api 570 Pipe Stress Analysis Hydraulic And Dynamic Transient Surge Analysis Pressure Testing And Internal Pipeline Inspection Services Projects May Include But Not Be Limited To Above And Below Ground Storage Tanks Hydrant Systems Fuel Distribution Pump Houses Truck Fill Stands Piping Valves Trenching Primary And Secondary Spill Containment Scada Systems And Pipeline Tank Leak Detection Systems Design Of Utilidors Fire Detection And Fire Protection Systems Mechanical And Electrical Systems And Communication Systems May Be Required But Are Incidental To Pol Design Project Sites May Be Local As Well As Remote The Ae And Their Subcontractors Must Have Experience In Cold Regions Design The Ae May Be Required To Participate In Programming Value Engineering And Design Charrettes And Project Review Conferences The Government May Require That Designs Be In Metric And Or English Systems Of Units Products Shall Be Produced To Corps Of Engineers Guidelines And Specific Formats As Set Forth By Task Order The Firm Must Demonstrate The Ability To Provide Drawings In Autocad Version As Required By The Project Use The Latest Version Of Mcaces Cost Estimating Software Furnished By The Government Provide A Cost Estimate In Work Breakdown Structure Wbs Using Mii Software Provide Draft Dd Form 1354 Transfer And Acceptance Of Military Real Property For Design Task Orders Provide Electronic Bid Set Ebs Documents And Use Specsintact For All Projects Unless Otherwise Directed In The Task Order Construction Support Services When Required Include Participation In On Site Partnering Pre Construction Meetings Review Construction Contractor S Submittals For Government Approval And For Information Only Participation In Site Visits And Provide Inspection Reports At Critical Points Of Construction Participation In Start Up And Commissioning Of The Systems Attending Warranty Inspections Participation In Lessons Learned Sessions Preparation Of Operations And Maintenance Support Information Manuals Construction Support Services May Be Contracted Using Time And Materials Processes The Ae Will Be Required To Use The Dr Check s Design Review And Checking System Permissions And Passwords Will Be Distributed On A Project By Project Basis Systems Information Required For Dr Checks Includes A Web Browser Program Either Internet Explorer Microsoft Or Navigator Netscape Versions 4 0 Or Later The Web Site Is Http Www Buildersnet Org Drchecks 3 Location Primarily Various Locations In Alaska But May Be Utilized Outside Alaska On An Exception Basis Facilities Will Generally Be Located In Arctic Subarctic And Cold Region Environments 4 Selection Criteria The Following Selection Criteria Are Listed In The Descending Order Of Importance Criteria A G Below Are Primary Selection Criterion Criteria H I Below Are Secondary And Will Only Be Used As Tie Breakers Among Technically Equal Firms Responding Firms Must Address Each Discipline Clearly Indicate Which Shall Be Subcontracted And Provide A Separate Sf330 Part Ii 6 2004 Edition For Each Subcontractor A Minimum Requirements For Professional Personnel In The Following Disciplines Two 2 Registered Mechanical Engineers Each With At Least Ten 10 Years Design Experience In Pol Systems One Of These Engineers With 5 Years Department Of Defense Dod Pol Experience The Following Required Disciplines Must Include At Least One 1 Individual With Professional Registration Architect Electrical Fire Protection Civil And Structural Engineers The Following Required Disciplines Must Include At Least One 1 Individual Certified Welding Engineer Inspector Nace Certified Cathodic Protection Specialist Surveyor Cost Estimator Environmental Engineer Asbestos Htrw Certified And Specification Writer If Specification Writer Is Not A Separate Discipline Please Clearly Describe How Specifications Will Be Produced B Specialized Experience And Technical Competence In Design Of New Dod Pol Related Facilities In Cold Regions Cold Regions Design Is Not Considered To Be A Separate Discipline That Can Be Subcontracted Rather Knowledge And Experience In The Design Construction And Operation Of Facilities In Arctic Subarctic And Cold Region Environments Must Be Integral To All Design Disciplines Design Of Dod Pol Related Facility Renovations Experience In Api Piping And Tank Inspections Construction Phase Services Preparing Design Build Rfps Design Charrettes Studies And Analyses Of Dod Pol Related Existing Facilities C Past Performance On Dod Desc Srm And Other Contracts With Respect To Cost Control Quality Of Work And Compliance With Schedules D Quality Control Quality Assurance Plan Please Describe How It Will Be Used To Assure A Quality Product To Include Discussion On Roles Responsibilities And Authorities Of The Team Involved In Qc Qa The Quality Control Quality Assurance Plan Must Address The Integration Of Work Products Of The Entire Team That Is Proposed E Capacity To Maintain Schedules And Accomplish Required Work On Three Simultaneous Task Orders F Knowledge Of Locality And Military Pol Facilities In Alaska Both Private And Military G Sustainable Design Using An Integrated Design Approach And Emphasizing Environmental Stewardship Especially Energy And Water Conservation And Efficiency Use Of Recovered And Recycled Materials Waste Reduction Reduction Or Elimination Of Toxic And Harmful Substances In Facilities Construction And Operation Efficiency In Resource And Materials Utilization Minimizing Maintenance Costs And Considering Overall Life Cycle Costs And Development Of Healthy Safe And Productive Work Environments The Evaluation Will Consider Projects Performed By The Prime Firm And Consultants That Demonstrate These Sustainable Design Principles As Well As The Qualifications Of The Key Personnel That Demonstrate Their Experience And Training In Sustainable Design H Secondary Evaluation Criteria That Would Be Used As Tie Breakers Include Geographic Proximity In Relation To The Projects And The Alaska District Headquarters In Anchorage I Secondary Evaluation Criteria That Would Be Used As Tie Breakers Include Volume Of Dod Contract Awards In The Last 12 Months J The Extent Of Participation Of Sb Sdb Historically Black Colleges And Universities Hbcu And Minority Institutions Mi In The Proposed Contract Team Measured As A Percentage Of The Total Anticipated Contract Effort Regardless Of Whether The Sb Sdb Hbcu Or Mi Is A Prime Contractor Subcontractor Or Joint Venture Partner The Greater The Participation The Greater The Consideration 4 Submission Requirements Firms Submitting Their Qualifications Should Provide Two Copies Of The Sf 330 And Must Include The Following Additional Information As Indicated A Part I Block C 11 Include If Previously Worked With Subcontractor And Estimated Percentage Involvement For Each Team Member B Part I Block F 24 Include Separate Values For Professional Fee And Construction For Each Project Identified And C Part I Block H 3 Address How Your Team Meets Each Selection Criterion Include An Organization Chart Of The Key Personnel To Be Assigned To The Project The 8 16 Edition Of The Sf330 Must Be Used And May Be Obtained From The Government Printing Office At Http Www Gsa Gov Portal Forms Type Sf Or From Commercial Software Suppliers For Use With Personal Computers And Laser Printers In Both Adobe Acrobat Pdf And Form Flow Formats Part I H Of The Sf 330 Describe The Firm S Overall Design Quality Management Plan A Detailed Contract Specific Design Quality Management Plan Which Includes Quality Control And Quality Assurance Plans Must Be Prepared For Government Approval As A Condition Of Contract Award But Is Not Required With This Submission Part I Of The Sf 330 Must Be Submitted It Is Preferred That Part Ii Of The Sf330 Be Submitted With Part I However The Part Ii Will Be Considered Submitted If A Current Version Updated Within The 36 Month Period Prior To The Date For Receipt Of Submissions Of The Part Ii Information Has Been Uploaded To The Sam Website W911kb20r0010 Pol Idiq Ak Contract Specialist George Nasifand Contracting Officer Theresa Afrank This Request Must Be Received No Later Than Seven 7 Calendar Days 8 April2020 Prior To The Proposal Due Date The Link To Drop Off The Proposal Will Be Valid Until The Due Date And Time For Proposal Receipt Hard Copies Of Proposals Will Not Be Accepted Offerors Must Submit Proposals To Be Received No Later Than 2 00 Pm Akdst 15 April 2020 No Arrangements Will Be Made By The Government To Assist In Sf330 Package Delivery Offerors Are Advised To Plan Accordingly Day Pass Procedures Will Not Be Used For Delivery Purposes Nor Are There Pick Up Services No Escort Services Will Be Provided It Is Incumbent On The Offeror To Plan For Unanticipated Delays In Delivery Of Sf330 Package Proposals Due To Heightened Security At Government Installations Visitors To The Elmendorf Air Force Base Joint Base Elmendorf Richardson Jber As Of 1 Oct 2010 Must Use The Boniface Gate Or Fort Richardson Gate Visitor Centers All Vehicle Occupants Are Required To Wear Seatbelts And Hand Held Cell Phone Usage By Vehicle Operators While Driving On Base Post Is Prohibited Violators Will Lose Their Base Post Driving Privileges For These Offenses Mailing Address U S Army Corps Of Engineers Alaska District Attn Cepoa Ct Nasif Room 30 Po Box 6898 Jber Alaska 99506 0898 Physical Address U S Army Corps Of Engineers Alaska District Attn Cepoa Ct Nasif 2204 3Rd Street Room 30 Jber Alaska 99506 Contracting Division Point Of Contact George Nasif 907 753 2838 Email Your Questions To Us Army Corp Of Engineers Alaska At George G Nasif Usace Army Mil Place Of Performance Address Us Army Corp Of Engineers Alaska District Cepoa Ct P O Box 6898 Jber Ak 99506 0898

Key Value

Tender Value
Refer document

Attachment

FileName File Description
Global Tender Document Tender Notice
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail