GTR 120625953
Bids Are Invited For Maintenance For Standby Generators
ICB — International Competitive Bid
Closes Dec 04, 2026
Northern America
Tender Information
GTR Reference
120625953
Tendering Authority
Subscribe to view
Tender No
1220-040-2026-085
Financer Name
Self-Funded
Work Title
Bids Are Invited For Maintenance For Standby Generators
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Northern America
Political Region
Asia-Pacific Economic Cooperation, APEC,G20,APAC (Asia Pacific)
Last Date of Bid Submission
04-12-2026
Work Detail
Request For Quotationsthe City Invites Quotations From Experienced And Qualified Contractors For The Provision Of Everything Required Including All Skilled Labour, Tools, Materials, Equipment For Scheduled Preventative Maintenance (“Pm”) Services, Repairs And Annual Load Bank Testing (“Lbt”) Of The City Of Surrey’S Emergency Standby Generators And Associated Equipment And Any Other Requirements.The City Does Not Guarantee Any Number Of The Emergency Standby Generators Will Require Services And May Increase Or Decrease The Number Of Emergency Standby Generators Requiring Service During The Term.The City Has 59 Emergency Standby Generators Located Throughout The City. Some Of The Generators Are Located At City Buildings And Pump Stations Where They Provide Emergency Backup Power In The Event Of A Power Loss.Monthly Pm Inspections(A) Disable Alarm System.(B) Check/Disable Scada System As Applicable Per Site.(C) Check/Clean Air Inlets And Exhaust For Obstructions.(D) Check For Signs Of Rodent/Animal Intrusions.(E) Check For Signs Of Water Ingress.(F) Check For Signs Of Oil/Coolant/Fuel Leaks.(G) Check Battery Voltage And Water Level.(H) Confirm Block Heater Is Operational.(I) Confirm Building Heating And Cooling Systems Are Operational.(J) Tidy Up Site To Ensure Safe Operation.(K) Drain Water From Fuel Filters.(L) Run City Fuel Polisher Assembly On Bulk Diesel Tank As Applicable.(M) Complete Generator Pm Per City Inspection Form Or Contractors Form (To Be Provided As Part Of The Submission.(N) Start And Run Generator.(O) Exercise Transfer Switch.(P) Re-Enable Scada & Alarm System Where Applicable.(Q) Complete And Provide To The City Completed Inspection Check Sheets Or Contractors Check Sheets.(R) During Generator Run, Confirm The Activation Of The Fire Alarm Panel Trouble Indicator, If Applicable.Addendaif The City Determines That An Amendment Is Required To This Rfq, The City Representative Will Issue A Written Addendum By Posting It On The Bc Bid Website At Www.Bcbid.Gov.Bc.Ca And The City Website At Www.Surrey.Ca (Collectively, The “Websites”), And Upon Posting, Any Addenda Will Form Part Of This Rfq. It Is The Responsibility Of Contractors To Check The Websites For Addenda. The Only Way This Rfq May Be Added To, Or Amended In Any Way, Is By A Formal Written Addendum. No Other Communication, Whether Written Or Oral, From Any Person Will Affect Or Modify The Terms Of This Rfq Or May Be Relied Upon By Any Contractor. By Delivery Of A Quotation, The Contractor Is Deemed To Have Received, Accepted And Understood The Entire Rfq, Including Any And All Addenda.All Inquiries Related To This Rfq Should Be Directed In Writing [email protected].
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
a25f76e9-c5f0-4101-a9b6-9ee1a2418770.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.