GTR 120149234

Request For Quotation Materials Required For Practical Training In The Specialty “Electrical Supply” (2026)

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
120149234
Tendering Authority
Subscribe to view
Tender No
17896432
Financer Name
Self-Funded
Work Title
Request For Quotation Materials Required For Practical Training In The Specialty “Electrical Supply” (2026)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
04-11-2026 Closed
Work Detail
Photo Relay Fr 600 1300Va Ip44 Ser. Iek Lfr20-600-1300-003Length (Mm) 105Height (Mm) 45Width (Mm) 65Weight (Grams) 74Othersmanufacturer Ieklighting Seriessensor Version Built-In Light Sensormaximum Switched Power 1300 Wmaterial Plasticrated Voltage, V 230 Vsuitable For Ip Degree Of Protection Ip44installation Method Open Installationsensor Type Built-In Light Sensorcolor Gray, Wire Pvs 3X1.5 Length (Mm) 200Height (Mm) 1.4Width (Mm) 350Weight (Grams) 123Othersmanufacturer Algiz Kpvs Seriescable/Wire Brand Pvsproduct/Component Type Wireexternal Cable Diameter, Mm 8.38 Mmprotective Ground Wire Yescore Insulation Polyvinyl Chloride (Pvc)Conductor Class (European Standards) 5 - Stranded Flexiblenumber Of Cores 3Core Marking Colorconductor Core Material: Bare Coppersheath Material Polyvinyl Chloride (Pvc)Presence Of Screen Nolow Smoke Emission According To En 61034-2 (Ng-Ls Version) Nonominal Conductor Cross-Section, Sq.Mm 1.5 Sq.Mmoperating Temperature, Degrees C 40, Overcurrent And Voltage Protection Relay Avr100t 380 V 100 A, Number Of Phases 3 - • Equipment Type: Multifunctional Voltage And Current Control And Protection Relay.• Model: Avr100t Or Equivalent.• Rated Operating Voltage: 3 × 380 V Ac With Neutral Conductor.• Number Of Phases: 3.• Mains Frequency: 50/60 Hz.• Maximum Adjustable Current: 100 A.• Overcurrent Protection Adjustment Range: 1-100A.• Overvoltage Protection Adjustment Range: 230–300 V.• Undervoltage Protection Adjustment Range: 110-210V.• Protection Response Time: Adjustable, 0.1–20 Seconds.• Restart Time After Restoration Of Normal Network Parameters: Adjustable, 0.1–300 Seconds.• Indication: Digital, Displaying Voltage And Current Values.• Mounting Type: Din Rail.• Connection Type: Terminal.• Degree Of Protection: Ip40 For The Version Specified In The Wattsap.Kz Catalog.• Operating Temperature: From −10 °C To +50 °C For The Version Specified In The Wattsap.Kz Catalog.• Purpose: Protection Of Electrical Equipment From High And Low Voltage, As Well As Current Overload.• Complete Set: Complete Protection Relay, Ready For Installation And Connection., Motion Sensor Iek Dd 019 Ldd13-019-1100-002, Ecosystem: Iek• Viewing Angle: The Horizontal (Usually 120° To 360°) And Vertical Viewing Area That Determines The Coverage Area. • Detection Range (Radius): The Maximum Distance At Which The Device Detects Movement (On Average From 6 To 12 Meters For Indoors). • Maximum Load Power: The Permissible Power Of The Connected Luminaires (For Example, 500–1200 W) So That The Device Does Not Fail. • Delay Time (Timer): The Interval During Which The Light Remains On After Traffic Stops (From 5 Seconds To 10-15 Minutes). • Light Threshold (Lux): The Level Of External Darkness At Which The Sensor Begins To Activate (Allows The Device Not To Turn On The Light During The Day). • Protection Degree (Ip): Level Of Resistance To Dust And Moisture (For Example, Ip20 For Dry Rooms, Ip44 Or Ip54 For Outdoors And Wet Areas). • Installation Height: Recommended Installation Height From The Floor (Usually 1.8 To 2.5 Meters)., Photo Relay 6A | V1-Sv01 | Varton• Supply Voltage: Typically 230 V (Ac 50 Hz).• Rated Load Current: From 6 A To 25 A (Determines The Maximum Power Of Connected Lamps - From 100 W To 5500 W).• Response Threshold (Sensitivity): Measured In Lux (Lx), The Standard Adjustment Range Is From 2 To 100 Lx (Adjustable Manually Or Automatically).• Degree Of Protection (Ip): For Outdoor Use, Choose Models With Ip44 Or Higher, For Installation Inside A Shield Indoors - Ip20.• Operating Temperature Range: Typically -25°C To +45–50°C For Outdoor Applications.• On/Off Delay: Prevents False Alarms From Brief Flashes Of Light (Such As The Headlights Of A Passing Car), Cable Vvgg 3 * 1.5 - Cable Vvg Is A Power Cable, Designed For The Transmission And Distribution Of Electrical Energy In Stationary Installations With A Rated Alternating Voltage Of 0.66 Or 1 Kv. It Is Used For Installation In Dry And Damp Rooms On Special Cable Racks, In Blocks, And Panels.- “B” - Pvc Insulation;- “B” - Pvc Shell;- “G” - Lack Of Armor (Naked);- Ng - A Shell Made Of Flame Retardant Material.The Conductor Material Is Copper.Number Of Cores: 3Core Cross-Section: 1.5 Mm2, Pva Wire 3*2.5 - Product Type – Flexible Power Cable With Copper Conductorsnumber Of Cores – 5 Cores (Phase, Neutral, Protective Conductor And Additional Cores)Core Cross-Section – 2.5Mm²core Material – Copper Stranded Wire (Gost 22483 77 / Iec Standard)Core Insulation – Pvc (Polyvinyl Chloride)Core Insulation Color – Different Colors To Identify Phases And Neutralsgeneral Shell – Pvc (Protection From Mechanical Damage, Flexibility During Installation)Rated Voltage – 380/660V Acoperating Temperature – From −15°C To +70°Capplication – Laying In Household And Industrial Electrical Networks, Lighting, Electrical Equipment, Control Panels; Suitable For Stationary Installation And Connection Of Household Appliancesstandards – Gost 22483 77, Iec 60227Installation – Flexible, Easy To Install In Boxes, Pipes And Cable Ducts; Protection Recommended For Outdoor Installation, Cable Vvg Ng 3*2.5 - Power Cable, With Copper Conductors, With Insulation Made Of Polyvinyl Chloride Plastic Compound, With An Outer Sheath Made Of Polyvinyl Chloride Plastic Compound.A Three-Core Wire With A Cross-Section Of 2.5 Mm2 Or Simply A 3X2.5 Mm2 Cable Is One Of The Most Popular Wires For Electrical Wiring At Home, In The Garage, In The Country, In The Office Or In Production. It Is Designed For Carrying, Powering Household And Industrial Equipment With Relatively Low Power Consumption. It Is Used, Depending On The Cable Type, For Stationary Or Mobile Carrying Type Wiring., Power Delay Timer Timer Relay 220V Ac Ah3-3 0-10 Seconds 60 Mins With 8 Pin Connector• T Type Of Equipment: Time Relay With Switch-On Delay.• Model: Ah3-2 Or Equivalent.• Rated Supply Voltage: 220 V Alternating Current (Ac).• Nominal Frequency: 50/60 Hz.• Time Delay Range: 0–60 Minutes.• Time Setting: Adjustable Using A Switch Or Regulator On The Body.• Number Of Pins: 8 Pins.• Type Of Contact Group: 2 Switching Contact Groups (2No/2Nc In Accordance With The Manufacturers Diagram).• Rated Switching Current: Not Less Than 5 A.• Housing Protection Degree: Ip20 Or Higher.• Connection Method: Via 8-Pin Connector.• Operating Mode: Switch-On Delay After Power Supply.• Purpose: Control Of Electrical Circuits, Lighting Systems, Automation And Industrial Equipment.• Complete Set: Time Relay And Corresponding 8-Pin Connector Block., Electric Motor Air 56A2 Im2081 (0.18 Kw/3000 Rpm) - Power - 0.18 Kwvoltage - 220 V, 300 V, 380 V / Speed - 3000 Rpm, Perforated Cable Channel 40X40 2M - Type – Perforated Cable Channel (Box) Section – 40×40 Mm (Width×Height) Length – 2 M (Standard) Material – Pvc (Polyvinyl Chloride) Plastic Or Abs Plastic Color – White (Ral 9016), Gray (Ral 7035), Brown (Ral 8017) Type Covers – Removable, With Latches Design – Base With Perforations (Holes For Fastening) Perforation – Round Or Oval Holes For Self-Tapping Screws (Pitch 100-150 Mm) Wall Thickness – 1.0-1.2 Mm Protection Class – Ip40 (Without Cover), Ip44 (With Cover) Operating Temperature – −25…+60 °С Installation Temperature – Not Lower −15 °C Resistance – To Moisture, Oils, Alkalis, Acids, Uv Radiation Flammability – Self-Extinguishing (V0 According To Ul94) Flexibility – None (Rigid Profile) Connection Method – Connectors (Couplings), Corners, T-Shaped Branches, Plugs Internal Volume – 1,600 Mm² (Useful Cross-Section) Maximum Filling – 40% Section (Pue) Weight 1 M – 0.5 Kg Coil Dimensions – 2000×40×40 Mm (Length×Width×Height) Standard – Gost 31565-2012, Iec 61084, En 50085 Certificates – Gost R, Rostest, Fire Certificate, Cable Channel With Cover 60X40 - Type – Cable Channel (Box) Perforated Or Solid Section – 60×40 Mm (Width×Height) Length – 2 M (Standard) Material – Pvc (Polyvinyl Chloride) Plastic Or Abs Plastic Color – White (Ral 9016), Gray (Ral 7035), Brown (Ral 8017) Type Covers – Removable, With Latches Design – Base With Perforations (Holes For Fastening) Or Solid Perforation – Round Or Oval Holes For Self-Tapping Screws Wall Thickness – 1.0-1.5 Mm Protection Class – Ip40 (Without Cover), Ip44 (With Cover) Operating Temperature – −25…+60 °С Installation Temperature – Not Lower Than −15 °С Resistance – K Moisture, Oils, Alkalis, Acids, Uv Radiation Flammability – Self-Extinguishing (V0 According To Ul94) Flexibility – None (Rigid Profile) Connection Method – Connectors (Couplings), Corners, T-Shaped Branches Internal Volume – 3,600 Mm² (Useful Cross-Section) Maximum Filling – 40% Of The Cross-Section (Pue) Weight 1 M – 0.8 Kg Coil Dimensions – 2000×60×60 Mm (Length×Width×Height) Standard – Gost 31565-2012, Iec 61084, En 50085 Certificates – Gost R, Rostest, Fire Certificate, Cable Channel With Cover 60X60 - Type – Cable Channel (Box) Perforated Or Solid Section – 60×60 Mm (Width×Height) Length – 2 M (Standard) Material – Pvc (Polyvinyl Chloride) Plastic Or Abs Plastic Color – White (Ral 9016), Gray (Ral 7035), Brown (Ral 8017) Type Covers – Removable, With Latches Design – Base With Perforations (Holes For Fastening) Or Solid Perforation – Round Or Oval Holes For Self-Tapping Screws Wall Thickness – 1.0-1.5 Mm Protection Class – Ip40 (Without Cover), Ip44 (With Cover) Operating Temperature – −25…+60 °С Installation Temperature – Not Lower Than −15 °С Resistance – K Moisture, Oils, Alkalis, Acids, Uv Radiation Flammability – Self-Extinguishing (V0 According To Ul94) Flexibility – None (Rigid Profile) Connection Method – Connectors (Couplings), Corners, T-Shaped Branches Internal Volume – 3,600 Mm² (Useful Cross-Section) Maximum Filling – 40% Of The Cross-Section (Pue) Weight 1 M – 0.8 Kg Coil Dimensions – 2000×60×60 Mm (Length×Width×Height) Standard – Gost 31565-2012, Iec 61084, En 50085 Certificates – Gost R, Rostest, Fire Certificate, Control Cabinet B (Shchmp-5 Ip 31 (1000X650x300) Iek) - Housing Type – Metal Distribution Cabinet (Shchmp1) Dimensions – 1000×650×300 Mm (Height×Width×Depth) Working Volume – 1000×650×300 Mm (Internal Usable Space) Material – Cold-Rolled Galvanized Steel (1.0...1.5 Mm) Coating – Powder Polymer Paint (Ral 7035, Gray) Number Of Doors – 1 Main (Front) Door Opening Angle – 120° (Right/Left) Degree Of Protection – Ip54 (Dust- And Splash-Proof) Explosion-Proof Version – No (Standard) Installation Type – Floor/Wall (With Lower Supports) Bottom Cable Entry – 4×M32, 2×M40 (With Glands) Upper Cable Entry – Optional (2×M25) Ventilation – No (Additional Installation Possible) Lighting – No (Led Panel Possible) Instrument Panel – Steel 2 Mm, M6 Fastening Load Capacity – 300 Kg (Payload) Mechanical Resistance – 1000 N (Lateral Load) Operating Temperature – −25…+40 °С Relative Humidity – 80% (At +25°С) Grounding – Internal Side Busbar Pe (6×20 Mm) Neutral Busbar – Internal Side Busbar N (6×20 Mm) Weight – 45 Kg Standard – Iec 61439-1, Iec 60529, Gost 51321.1, Gost 14254-2015, Limit Switch Me-8112• Number Of Contacts – 1 No + 1 Nc Type Of Contacts – • Certification: Ce; • Drive Type: Parallel Roller Plunger, Automatic Reset; • Contact Configuration: 1 No + 1 Nc; • Degree Of Protection: Ip65; • Rated Voltage: • Alternating Current: 250 V 5 A;• Direct Current: 115 V 0.4 A;• Fastening Thread Diameter: 45 Mm; • Roller Diameter: 12.8 Mm; • Operating Speed: 0.5 Mm – 50 Cm/Sec; • Operating Frequency: • Mechanical: 120 Operations/Minutes;• Electric: 30 Operations/Minutes;• Contact Resistance: Max. 25 Mohm (Initial Value); • Ambient Temperature: From -5 To 65 °C; • Overall Size: 110X28x25 Mm; • • Material: Metal, Plastic, Rubber;, Prefix Pki-11 Additional Contacts 23+2Р - Kosymsha Module - Electric Switch (Contactor) Functional Element. Contactor Blogs (2Nc+2No). Contact. Prefix. Plastic. 10 A. 44X36x48 / Number Of Contacts 2No + 2Nc (2Z+2P), Rated Current 10 A, Case Material - Plastic, Overall Dimensions (44X36x48 Mm)., Contactor 3 No + 1No 230 Ac Electromagnetic Contactor - Rated Insulation Voltage (Ui) – 690 V Rated Operating Voltage (Ue) – Up To 400 V Rated Operating Current (Ie, Ac-3) – 9 A Number Of Main Contacts – 3 No Number Of Additional Contacts – 1 No Control Coil Voltage (Us) – 230 V Ac Operating Range Of Coil Voltage – 0.85…1.1 Us Coil Frequency – 50/60 Hz Coil Power Consumption (Switching On) – 65 Va Coil Power Consumption (Holding) – 8 Va Application Category – Ac-3 (Asynchronous Motors) Pulse Overvoltage (Uimp) – 6 Kv Additional Contact Current (Ac-15, 230 V) – 6 A Mechanical Wear Resistance – ≥ 10,000,000 Cycles Electrical Wear Resistance (Ac-3) – ≥ 1,000,000 Cycles Connected Conductor Cross-Section – 1…6 Mm² Protection Degree – Ip20 Operating Temperature – −25…+55 °С Mounting Type – Din Rail 35 Mm Housing Material – Polyamide, Self-Extinguishing Weight – 0.35 Kg Standard – Iec/En 60947-4-1, Gost R 50030.4.1
Key Value
Tender Value
1,833,000 - KZT
Tender Documents
Global Tender Document
94a5cdd5-2288-4da1-870a-10618ec4ba6d.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you