GTR 120104219
Request For Quotation Purchase Of Goods: Medical Products For Paid Services
ICB — International Competitive Bid
Central Asia
Tender Information
GTR Reference
120104219
Tendering Authority
Subscribe to view
Tender No
17880120
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Goods: Medical Products For Paid Services
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
03-11-2026
Work Detail
D-Dimer R1:1×40 Ml+R2:1×15 Ml+Calibrator:6×0.5 Mlr1:1×40 Ml+R2:1×15 Ml+Calibrator:6×0.5 Ml, Specific Protein Calibrator 5X1 Ml (C3, C4, Crp, Iga, Igg, Igm) 5 Ampoules Of 1 Ml, C-Reactive Protein R-1 1*40 Ml, R-2 1*10 Ml. (Srb) (Nephelometry Method) 1X40 +1X10, Lactate Dehydrogenase R1: 4X35 Ml + R2: 2X18 Ml. (Ldh) (Kinetic, Uv Method) (Ifcc) 4Х35 +2Х18, Total Cholesterol One-Component Reagent Kit For The Determination Of Chol/Tc. The Volume Of The Working Solution Is At Least 160 Ml. The Reagent Must Be Packaged In The Original R1 Disposable Container To Prevent Contamination And Does Not Require Transfer To An Additional Cartridge. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel. Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 728 Studies, Direct Bilirubin Two-Component Reagent Kit For The Determination Of Dbil/Vox. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel.Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 824 Studies, Total Bilirubin Two-Component Reagent Kit For The Determination Of Tbil/Vox. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carouselcompatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 824 Studies, Total Protein Kit One-Component Reagent Kit For The Determination Of Tp. The Volume Of The Working Solution Is At Least 160 Ml. The Reagent Must Be Packaged In The Original R1 Disposable Container To Prevent Contamination And Does Not Require Transfer To An Additional Cartridge. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel. Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 1428 Studies, Urea Kit Two-Component Reagent Kit For The Determination Of Bun/Urea. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel. Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 600 Studies, Set Of Reagents “Indicator Cardboard Discs With Antimicrobial Drugs”Means Cefoperazone/Sulbactam 75/30 Mcg. Designed To Determine The Sensitivity Of Microorganisms To Antimicrobial Drugs And Confirm The Production Of Extended-Spectrum Betalactamases By Enterobacteria Using The Disk Diffusion Method. Set Of Discs No. 1 Is Intended For Determining The Sensitivity Of Pathogens To The General Range Of Antimicrobial Drugs. Sets Of Discs No. 2-29 Are Intended For Determining Sensitivity To Certain Groups Of Antimicrobial Drugs. Kits No. 30-132 Are Intended For Determining Sensitivity To A Specific Type Of Antimicrobial Drug. All Sets Of Reagent Kits Allow For Separate Studies Using The Required Number Of Disks. Shelf Life 25 Months., Set Of Reagents “Indicator Cardboard Discs With Antimicrobial Drugs”Meanscefoxitin 30 Mcg. Designed To Determine The Sensitivity Of Microorganisms To Antimicrobial Drugs And Confirm The Production Of Extended-Spectrum Betalactamases By Enterobacteria Using The Disk Diffusion Method. Set Of Discs No. 1 Is Intended For Determining The Sensitivity Of Pathogens To The General Range Of Antimicrobial Drugs. Sets Of Discs No. 2-29 Are Intended For Determining Sensitivity To Certain Groups Of Antimicrobial Drugs. Kits No. 30-132 Are Intended For Determining Sensitivity To A Specific Type Of Antimicrobial Drug. All Sets Of Reagent Kits Allow For Separate Studies Using The Required Number Of Disks. Shelf Life 25 Months., Set Of Reagents “Indicator Cardboard Discs With Antimicrobial Drugs”Means Cephalexin 30 Mcg. Designed To Determine The Sensitivity Of Microorganisms To Antimicrobial Drugs And Confirm The Production Of Extended-Spectrum Betalactamases By Enterobacteria Using The Disk Diffusion Method. Set Of Discs No. 1 Is Intended For Determining The Sensitivity Of Pathogens To The General Range Of Antimicrobial Drugs. Sets Of Discs No. 2-29 Are Intended For Determining Sensitivity To Certain Groups Of Antimicrobial Drugs. Kits No. 30-132 Are Intended For Determining Sensitivity To A Specific Type Of Antimicrobial Drug. All Sets Of Reagent Kits Allow For Separate Studies Using The Required Number Of Disks. Shelf Life 25 Months., Set Of Reagents “Indicator Cardboard Discs With Antimicrobial Drugs”Means Cefazolin 30 Mcg. Designed To Determine The Sensitivity Of Microorganisms To Antimicrobial Drugs And Confirm The Production Of Extended-Spectrum Betalactamases By Enterobacteria Using The Disk Diffusion Method. Set Of Discs No. 1 Is Intended For Determining The Sensitivity Of Pathogens To The General Range Of Antimicrobial Drugs. Sets Of Discs No. 2-29 Are Intended For Determining Sensitivity To Certain Groups Of Antimicrobial Drugs. Kits No. 30-132 Are Intended For Determining Sensitivity To A Specific Type Of Antimicrobial Drug. All Sets Of Reagent Kits Allow For Separate Studies Using The Required Number Of Disks. Shelf Life 25 Months., Set Of Reagents “Indicator Cardboard Discs With Antimicrobial Drugs”Means Chloramphenicol 30 Mcg. Designed To Determine The Sensitivity Of Microorganisms To Antimicrobial Drugs And Confirm The Production Of Extended-Spectrum Betalactamases By Enterobacteria Using The Disk Diffusion Method. Set Of Discs No. 1 Is Intended For Determining The Sensitivity Of Pathogens To The General Range Of Antimicrobial Drugs. Sets Of Discs No. 2-29 Are Intended For Determining Sensitivity To Certain Groups Of Antimicrobial Drugs. Kits No. 30-132 Are Intended For Determining Sensitivity To A Specific Type Of Antimicrobial Drug. All Sets Of Reagent Kits Allow For Separate Studies Using The Required Number Of Disks. Shelf Life 25 Months., Set Of Reagents “Indicator Cardboard Discs With Antimicrobial Drugs”Means Fluconazole 10 Mcg. Designed To Determine The Sensitivity Of Microorganisms To Antimicrobial Drugs And Confirm The Production Of Extended-Spectrum Betalactamases By Enterobacteria Using The Disk Diffusion Method. Set Of Discs No. 1 Is Intended For Determining The Sensitivity Of Pathogens To The General Range Of Antimicrobial Drugs. Sets Of Discs No. 2-29 Are Intended For Determining Sensitivity To Certain Groups Of Antimicrobial Drugs. Kits No. 30-132 Are Intended For Determining Sensitivity To A Specific Type Of Antimicrobial Drug. All Sets Of Reagent Kits Allow For Separate Studies Using The Required Number Of Disks. Shelf Life 25 Months., Set Of Reagents “Indicator Cardboard Discs With Antimicrobial Drugs”Means Trimethoprim/Sulfamethoxazole 1.25-23.75 Mcg. Designed To Determine The Sensitivity Of Microorganisms To Antimicrobial Drugs And Confirm The Production Of Extended-Spectrum Betalactamases By Enterobacteria Using The Disk Diffusion Method. Set Of Discs No. 1 Is Intended For Determining The Sensitivity Of Pathogens To The General Range Of Antimicrobial Drugs. Sets Of Discs No. 2-29 Are Intended For Determining Sensitivity To Certain Groups Of Antimicrobial Drugs. Kits No. 30-132 Are Intended For Determining Sensitivity To A Specific Type Of Antimicrobial Drug. All Sets Of Reagent Kits Allow For Separate Studies Using The Required Number Of Disks. Shelf Life 25 Months., Set Of Reagents “Indicator Cardboard Discs With Antimicrobial Drugs”Means Ticarcillin/Clavolunate. Designed To Determine The Sensitivity Of Microorganisms To Antimicrobial Drugs And Confirm The Production Of Extended-Spectrum Betalactamases By Enterobacteria Using The Disk Diffusion Method. Set Of Discs No. 1 Is Intended For Determining The Sensitivity Of Pathogens To The General Range Of Antimicrobial Drugs. Sets Of Discs No. 2-29 Are Intended For Determining Sensitivity To Certain Groups Of Antimicrobial Drugs. Kits No. 30-132 Are Intended For Determining Sensitivity To A Specific Type Of Antimicrobial Drug. All Sets Of Reagent Kits Allow For Separate Studies Using The Required Number Of Disks. Shelf Life 25 Months., Set Of Reagents “Indicator Cardboard Discs With Antimicrobial Drugs”Means Ticarcillin. Designed To Determine The Sensitivity Of Microorganisms To Antimicrobial Drugs And Confirm The Production Of Extended-Spectrum Betalactamases By Enterobacteria Using The Disk Diffusion Method. Set Of Discs No. 1 Is Intended For Determining The Sensitivity Of Pathogens To The General Range Of Antimicrobial Drugs. Sets Of Discs No. 2-29 Are Intended For Determining Sensitivity To Certain Groups Of Antimicrobial Drugs. Kits No. 30-132 Are Intended For Determining Sensitivity To A Specific Type Of Antimicrobial Drug. All Sets Of Reagent Kits Allow For Separate Studies Using The Required Number Of Disks. Shelf Life 25 Months., Control Blood On Sysmex Xp-300 (Normal). Control Blood (Normal) To Check The Precision And Accuracy Of Hematological Analyzers For 16 Diagnostic And 6 Service Parameters. Designed For Use In Sysmex Xp-300 Hematology Analyzers, Control Blood On Sysmex Xp-300 (Low Level). Control Blood For Testing The Precision And Accuracy Of Hematological Analyzers For 16 Diagnostic And 6 Service Parameters Intended For Use In Sysmex Xp-300 Hematological Analyzers
Key Value
Tender Value
2,391,910 - KZT
Tender Documents
Global Tender Document
d709bb56-13d5-420d-a1ac-edb9a49a502e.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.