GTR 119917474

Request For Quotation Laboratory Consumables

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
119917474
Tendering Authority
Subscribe to view
Tender No
17862125
Financer Name
Self-Funded
Work Title
Request For Quotation Laboratory Consumables
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
29-10-2026 Closed
Work Detail
D-1552 Vecto Cmv-Igm Strip For 96 Determinations. A Set Of Reagents For The Enzyme-Linked Immunosorbent Detection Of Class M Immunoglobulins To Cytomegalovirus In Blood Serum (Plasma), Number Of Determinations 12X8, D-1554 Vecto Cmv-Igg Strip For 96 Determinations. Set Of Reagents For Enzyme Immunoassay Detection Of Class G Immunoglobulins To Cytomegalovirus In Blood Serum (Plasma), Number Of Determinations 12X8., D-2152 Vecto Hsv-Igg Strip For 96 Definitions. A Set Of Reagents For The Enzyme-Linked Immunosorbent Detection Of Class G Immunoglobulins To Herpes Simplex Virus Types 1 And 2 In Blood Serum (Plasma), Number Of Determinations 12X8., D-2154 Vecto Hsv-Igm Strip For 96 Determinations. Set Of Reagents For Enzyme Immunoassay Detection Of Class M Immunoglobulins To Herpes Simplex Virus Types 1 And 2, Number Of Determinations 12X8, Dat-Gardnerella-Igg\Iga For 96 Determinations. Set Of Reagents For Detection Of Antibodies Of Classes G And M To Gardnerella Vaginalis By Enzyme Immunoassay, Number Of Determinations 96. St 96818-1910- Too -32-2017, Urea 10505. Kinetic Test For The Determination Of Urea In Serum, Plasma And Urine “Urea Liquicolor” Packaging 2X100 Ml. Method. Urea Hydrolyzes In The Presence Of Water And Urease To Form Ammonia And Carbon Dioxide. In The Modified Berthelot Reaction, Ammonia Ions React With Hypochlorite And Salicylate To Produce A Green Color. The Increase In Absorbance At 578 Nm Is Proportional To The Concentration Of Urea In The Test Sample. Reagent 1 Phosphate Buffer (Ph 7.0) 120 Mmol/L Sodium Salicylate 60 Mmol/L Sodium Nitroprusside 5 Mmol/L Edta 1 Mmol/L Reagent 2. Phosphate Buffer (Ph < 13) 120 Mmol/L Hypochlorite ≈ 0.6 G/L Cl Urease Enzyme > 500 Ku/L Standard 3 Ml Urea Standard 3 Ml Urea Equivalent To Bun 37.28 Mg/Dl Or 6.2 Mmol/L Sodium Azide 0.095% Reagent Stability. Reagents Are Stable Until Their Expiration Date Provided They Are Stored Unopened At 2...8°C. [Rgt1], [Rgt2] And [Enz] Are Stable For 6 Weeks After Opening If Stored At 2...8°C Or 2 Weeks At 15...25°C. The Standard Is Stable Until The Expiration Date, Even After Opening. Enzyme Reagent 1A Is Stable For 4 Weeks At A Temperature Of 2...8°C Or 2 Weeks At A Temperature Of 15...25°C., Creatinine 10051. Kinetic Method Without Deproteinization For Measuring Creatinine In Serum, Plasma And Urine “Creatinine Liquicolor” Packaging 200 Ml No Less Complexity Sodium Hydroxide Xi, (R36/38) (S 26-37/39-45) 2×100 Ml No Less Picric Acid 1×50 Ml Standard Createnine 1×5 Ml Scope Of Application The Test Is Used In Clinical Diagnostic Laboratories Of Medical Organizations And Is Intended For The Quantitative Determination Of Creatinine In Human Serum, Heparinized Plasma And Urine. Method Principle 1.2 Creatinine Reacts With Picric Acid In An Alkaline Medium To Form An Orange-Red Complex. The Optical Density Of The Resulting Complex Is Proportional To The Concentration Of Creatinine In The Sample. Reaction Scheme Creatinine + Picric Acid ------> Creatinine-Picrate Complex. Stability Of Reagents Reagents Are Stable Even After Opening The Package Up To The Stated Expiration Date [  ] If They Are Stored In A Closed Container At A Temperature [  ] Between +15°C And +25°C. Contamination Of Reagents Should Be Avoided. The Working Reagent Is Stable For 4 Weeks At Temperatures Between +15°C And +25°C In A Closed Container, Protected From Light. Definition Wavelength: Hg 492 Nm (490-510 Nm) Optical Path: 1Cm Temperature: +37°C Measurement: Against Air (Increasing Optical Density). Warm The Reagents And Cuvettes To The Desired Temperature And Maintain It Constant (± 0.5°C) Throughout The Test., Glucose 10260. Enzymatic Colorimetric Test For Determining Glucose Without Deproteinization In Serum And Blood Plasma “Glucose Liquicolor” Packaging 4X100 Ml No Less Method: Glucose Is Enzymatically Oxidized In The Presence Of Glucose Oxidase. The Hydrogen Peroxide Formed During The Reaction Reacts In The Presence Of Peroxidase With Phenol And 4-Aminophenazone And Forms A Red-Violet Quinone-Imine Product, Which Is Photometric. Enzymatic Reagent Phosphate Buffer (Ph 7.5) 0.1 Mol/L 4-Aminophenazone 0.25 Mmol/L Phenol 0.75 Mmol/L Glucose Oxidase (Go) > 15 Ku/L Peroxidase (P) > 1.5 Ku/L Mutarotase > 2.0 Ku/L Stabilizers Deproteinizing Solution Uranil Acentate 1.6 G/L Sodium Chloride 9 G/L Reagent Stability Reagents Are Stable Until The Indicated Date (Exp. Date) At A Storage Temperature Of 2..8ºс. After Opening The Vials, Avoid Bacterial Contamination Of The Reagents. The Enzyme Reagent Is Stable For 2 Weeks At A Temperature Of 15-25ºc. Linearity Of The Reagent The Test Is Linear Up To A Glucose Concentration Of 700 Mg/Dl Or 38.85 Mmol/L. If The Glucose Concentration In The Sample Exceeds The Specified Values, Dilute The Deproteinized Supernatant With Deproteinizing Solution In A 1:1 Ratio And Repeat The Test. Multiply The Result By 2 (Dilution Factor)., Bilirubin 10740. Bilirubin D+T Test - Bilirubin Direct/Total, Complete Test Kit, 2X100 Ml Indirect Bilirubin Is Released Under The Influence Of A Detergent. Direct/Total Bilirubin Reacts With The Diazo Complex 3,5-Dichlorophenyl-Diazonium-Tetrafluoroborate (Dpd) To Form Azobilirubin. The Optical Density Of Azobilirubin At 546 Nm Is Directly Proportional To The Concentration Of Total Bilirubin In The Sample Rgt 1. Detergent (Green Cap) 3,5-Dichlorophenyl-Diazonium-Tetrafluoroborate 0.9 Mmol/L Caffeine 5.2 Mmol/L Detergent Preservative Rgt 2. Coloring Reagent (Black Cap) For Determination Of Total Bilirubin Sodium Nitrite 390 Mmol/L Preparation And Stability Of Reagents. The Reagents Are Ready For Use. Before Opening, The Reagents Are Stable Until The Indicated Date At A Storage Temperature Of 2...8°C. After Opening, The Reagents Remain Stable For 30 Days When Stored “On Board” The Analyzer At 2...12°C. The Coloring Reagent Should Be Protected From Light. Serum, Heparinized Plasma. Avoid Hemolysis! Samples Must Be Protected From Light. Bilirubin In The Sample Is Stable When Stored In A Dark Place For 3 Days At A Temperature Of 2...8°C Or 3 Months At –20°C. Measurement Conditions. Wavelength 546 Nm (520-560 Nm) Optical Path 1 Cm Temperature 20°C Or 37°C Measurement Against A Reagent Blank, Reaction With Increasing Optical Density., Cat 12011. Liquid-Uv Test For Determining The Activity Of Alanine Aminotransferase - Asat In Serum And Blood Plasma “Gpt (Asat) Ifcc Mod. Liquiuv Humazym Test, Packaging 10X10ml No More, R1 - Reagent 1, Enzymatic Reagent Tris Buffer (Ph 7.5) - 100 Mmol/L L-Alanine - 500 Mmol/L. Lactate Dehydrogenase (Ldh) > 1200 U/L R2 - Reagent 2, Starting Reagent 2-Oxoglurate 15 Mmol/L Nadh 0.18 Mmol/L. Samples. Serum Or Plasma Treated With Heparin Or Edta Plasma. Avoid Hemolysis! Loss Of Activity Over 3 Days Is: At +4°C ~ 10%, At 20-25°C – 17% Measurement Conditions. Wavelength Hg 365 Nm, 340 Nm Or Hg 334 Nm Optical Path 1 Cm Temperature 25°C, 30°C Or 37°C. Measurement: Against Air (Or Distant Water), Reaction With A Decrease In Optical Density Calculation To Calculate The Change In Optical Density. Density In 1 Minute (Da/Min) In The Range Of 0.06-0.08 (Hg 365 Nm) Or 0.12-0.16 (Hg 334 Nm, 340 Nm) (Procedures 1+2), Use Only The Measurement Results Of The First 2 Minutes (1 Minute Of Incubation, 2 Minutes Of Measurement)., Alat 12011. Liquid-Uv Test For Determining The Activity Of Alanine Aminotransferase - Alat In Serum And Blood Plasma “Gpt (Alat) Ifcc Mod. Liquiuv Humazym Test, Packaging 10X10ml No More, R1 - Reagent 1, Enzymatic Reagent Tris Buffer (Ph 7.5) - 100 Mmol/L L-Alanine - 500 Mmol/L. Lactate Dehydrogenase (Ldh) > 1200 U/L R2 - Reagent 2, Starting Reagent 2-Oxoglurate 15 Mmol/L Nadh 0.18 Mmol/L. Samples. Serum Or Plasma Treated With Heparin Or Edta Plasma. Avoid Hemolysis! Loss Of Activity Over 3 Days Is: At +4°C ~ 10%, At 20-25°C – 17% Measurement Conditions. Wavelength Hg 365 Nm, 340 Nm Or Hg 334 Nm Optical Path 1 Cm Temperature 25°C, 30°C Or 37°C. Measurement: Against Air (Or Distant Water), Reaction With A Decrease In Optical Density Calculation To Calculate The Change In Optical Density. Density In 1 Minute (Da/Min) In The Range Of 0.06-0.08 (Hg 365 Nm) Or 0.12-0.16 (Hg 334 Nm, 340 Nm) (Procedures 1+2), Use Only The Measurement Results Of The First 2 Minutes (1 Minute Of Incubation, 2 Minutes Of Measurement)., Isotonic Diluent - Diluent, 20 L. For The Automatic Hematology Analyzer Humacount 80Ts Hc-Diluent 20 L, In A Plastic Container, Closed With A White Screw Cap, Label With A Green Stripe. An Isotonic Saline Solution Used To Dilute Whole Blood Samples And Flush The Fluid System Between Measurements. Sodium Sulfate (1%), Inorganic Phosphate Buffer (<0.6%), Sodium Chloride (<0.3%), Sodium Azide (<0.05%) For Humacount Automatic Hematology Analyzer, Dat – Myco- Igg\Igm For 96 Determinations. Set Of Reagents For Detection Of Class G And M Antibodies To Mycoplasma Hominis By Enzyme Immunoassay, 96 Units, Slide Glasses 26*52*1.2Mm (50 Pcs Per Pack). Slide Glass With Polished Edges With Matte And Without Matte Field For Inscriptions, Camomile-Toxo–G/M Set Of Reagents For The Detection Of Class G And M Antibodies To Toxoplasma Gondii By Enzyme Immunoassay. Set Of Reagents For Enzyme Immunoassay Detection Of Class M Immunoglobulins To Toxoplasma Gondii, Number Of Determinations 12X8, Cleaning Solution Hc - Cleaner, 1 L For Automatic Hematology Analyzer Humacount 80Ts Hc-Cleaner1 L, In A Plastic Container, Closed With A White Screw Cap, Label With A Blue Stripefor Purification Of Liquids Sodium Phosphate (<1%), Sodium Chloride (<1%), Surfactants (<2%), Sodium Azide (<0.05%), Bromocresol Green (<0.001%) For The Automatic Hematology Analyzer Humacount 80Ts, Lyse Reagent Hc - Lyse Cf, 1 L For Automatic Hematology Analyzer Humacount 80Ts Hc-Lyse Cf2x1 L, In A 1 L Plastic Container, Closed With A White Screw Cap, Label With A Yellow Stripecreates Hemolysate For 3-Way Wbc Differential And For Total Wbc And Hgb Values. Quaternary Ammonium Salts (2.7%), Surfactants (<0.05%) For Humacount 80Ts Automatic Hematology Analyzer, Rpr-Carbon - Dac Test For Syphilis Analog Of Rmp Agglutination On A Slide (Kit, 1000 Samples). Non-Treponemal Serological Tests Of Rapid Plasma Reagins - Rapid Plasma Reagins - Rpr. Macroscopic, Non-Treponemal, Flocculation Rpr Test With Plasma Or Serum., Calibration Solutions: Humatrol P 6X5 Ml. Humatrol P Is A Serum For Quality Control Of Clinical Biochemical Studies. Each Kit Contains 6Í5.0 Ml Of Reagent For Performing In Vitro Ivd Diagnostic Studies. Product Catalog Number Ref 13512. Humatrol P Lyophilisate, Calibration Solutions: Humatrol N 6X5 Ml Humatrol. N - Serum For Quality Control Of Clinical Biochemical Studies Control. Each Kit Contains Reagent In An Amount Of 6Í5.0 Ml To Perform Diagnostic Kit 1 39 850 In Vitro Ivd Studies. Product Catalog Number Ref 13511. Humatrol N Lyophilisate Prepared From Bovine Serum With A Specified Content Of All Important Components Of Human Serum.
Key Value
Tender Value
2,750,500 - KZT
Tender Documents
Global Tender Document
d865c1d0-9e98-4f31-878d-6358e216d8e8.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you