GTR 119895737

Tenders Are Invited For Medical Equipments, Pharmaceuticals And Personal Care Products – Medical Devices And Medical Consumables For Interventional Cardiology – Stents And Distal Embolic Protection.

ICB — International Competitive Bid Closes Nov 23, 2026 Southern Europe
Tender Information
GTR Reference
119895737
Tendering Authority
Subscribe to view
Tender No
743838-2026
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Medical Equipments, Pharmaceuticals And Personal Care Products – Medical Devices And Medical Consumables For Interventional Cardiology – Stents And Distal Embolic Protection.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Southern Europe
Last Date of Bid Submission
23-11-2026
Work Detail
Medical Equipments, Pharmaceuticals And Personal Care Products – Medical Devices And Medical Consumables For Interventional Cardiology – Stents And Distal Embolic Protection.. Medical Devices And Medical Consumables For Interventional Cardiology – Stents And Distal Embolic Protection.,Coronary Stent With A Sinusoidal Configuration And A Permanent Polymer Coating Containing A Cytostatic Agent From The “-Limus” Family (Des), With A Platinum-Iridium Core For Enhanced Radiopacity, An Outer Cobalt-Chromium Layer, And Platinum-Iridium Markers; Minimum Stent Diameter Range 2.25–4.0 Mm And Minimum Length Range 8–38 Mm.,Coronary Stent With A Permanent Polymer Coating Containing A Cytostatic Agent From The Limus Family (Des), With A Platinum-Iridium Core For Enhanced Radiopacity, An Outer Cobalt-Chromium Layer, And Platinum-Iridium Markers; Minimum Stent Diameter Range 2.0–5.00 Mm, With Overexpansion Capability Up To 6.00 Mm (For 4.5–5.0 Mm Diameters), And A Minimum Length Range Of 8–38 Mm.,Coronary Stent Designed For The Treatment Of Large-Lumen Blood Vessels, With High Radial And Axial Strength, Made Of Platinum-Chromium Alloy, Abluminally Coated With A Bioresorbable Plga Polymer And The Cytostatic Agent Everolimus (Des), With A Dual-Layer Balloon System, A Diameter Range Of 3.5–5 Mm, And A Length Range Of 8–32 Mm. The Stent Can Be Further Expanded Up To A Maximum Diameter Of 6 Mm.,Coronary Stent Made Of Platinum-Chromium Alloy, With A Thin Stent Strut Profile ≤81 Μm, A Non-Linear Link Design With An Open-Cell Configuration, Abluminally Coated With A Bioresorbable Plga Polymer And The Cytostatic Agent Everolimus (Des), With A Dual-Layer Balloon System, A Diameter Range Of 2.25–5 Mm, And A Length Range Of 8–48 Mm, Compatible With A 5F Guiding Catheter For All Sizes.,Self-Expanding Cobalt-Chromium Stent For Carotid Arteries, Compatible With A 0.014 Guidewire And A 5F Introducer Sheath, With A Straight And Tapered Closed-Cell Design, A Diameter Range Of 6–10 Mm, And A Length Range Of 30–50 Mm.,Coronary Stent Made Of Cobalt-Chromium Alloy, With An Open-Cell Design And A Biodegradable Polymer Coating, Coated With The Immunosuppressive Drug Sirolimus, With A Stent Strut Thickness Of 60 Μm, Featuring Probio Coating (Amorphous Silicon Carbide), A Diameter Range Of 2.25–4 Mm, And A Length Range Of 9–40 Mm.,Peripheral Balloon-Expandable Stent, Made Of Cobalt-Chromium, With An Otw (Over-The-Wire) System, Compatible With A 6F Introducer Sheath, With A Strut Thickness Of 110 Μm (For Stents With Diameters Of 5–7 Mm), Featuring Probio Coating, With 2 Markers, On A 90, 135, And 170 Cm Delivery Catheter, With A Stent Length Range Of 18–78 Mm And A Diameter Range Of 5–10 Mm.,Coronary Stent Made Of Cobalt-Chromium Alloy, With A Non-Linear Multi-Link Cell Design, Coated With A Permanent Polymer And The Cytostatic Agent Everolimus (Des), With A Diameter Range Of 2–4 Mm And A Length Range Of 8 Mm To At Least 38 Mm, Compatible With A 5F Guiding Catheter For All Sizes.,Coronary Stent Made Of Cobalt-Chromium Alloy, With A Multi-Link, Non-Linear Link Stent Design, Intended For Large-Diameter Coronary Arteries, Coated With A Permanent Polymer And The Cytostatic Agent Everolimus (Des), With A Low Stent Crossing Profile Of ≤0.039 (For A 3 Mm Stent Diameter), A Diameter Range Of 2.25–4 Mm, And A Length Range Of 8–38 Mm, With Expansion Capability Up To 5.5 Mm For 3.5,Peripheral Nitinol Stent System, Self-Expanding, With A Woven Mesh Design, Flexible And Kink-Resistant, Intended For Interventions In The Femoral And Popliteal Arteries, With A Diameter
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
b96a08e3-e551-4d8b-847d-bc51e066fb2b.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you