GTR 119781444
Request For Quotation Purchase Of Other Goods
ICB — International Competitive Bid
Closes Oct 29, 2026
— 4 days left
Central Asia
Tender Information
GTR Reference
119781444
Tendering Authority
Subscribe to view
Tender No
17853833
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Other Goods
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
29-10-2026
4 days left
Work Detail
Dielectric Gloves To Protect Hands From Electric Shock. 1. Product Type: Dielectric Gloves, Seamless. 2.Material Of Manufacture: Natural Latex Or Special Electrical Insulating Rubber. 3. Purpose: Protecting Hands From Electric Shock When Performing Electrical Installation And Electrical Work. 4.Protection Class - 0. 5.Maximum Operating Voltage - Up To 1000 V Ac. 6. Test Voltage - 5 Kv Ac. 7.Form Of Execution: Five-Fingered. 8.Surface: Smooth Or Corrugated, Without Cracks, Punctures Or Other Damage. 9.Size: Universal Or According To The Size Provided By The Manufacturer. 10.Marking - The Product Or Packaging Must Indicate The Manufacturer, Protection Class, Size, Date Of Manufacture And Information About Compliance With The Requirements Of The Applicable Standard. 11.Gloves Must Be New, Not Used, Without Mechanical Damage. To Agree With The Customer 8 705 640 87 18, Box (Housing) For A Three-Phase Circuit Breaker, 63 A. 1. Purpose: For Installation And Protection Of The Circuit Breaker In Electrical Networks. 2. Execution: Housing For Modular Electrical Equipment. 3. The Number Of Poles Of The Installed Circuit Breaker Is 3. 4. Compatibility: With A Three-Pole Circuit Breaker With A Rated Current Of 63 A. 5. Capacity: At Least 3 Modules With A Width Of 18 Mm. 6.Shell Material: High-Impact Electrical Insulating Plastic Or Equivalent Material. 7.Mounting Method: Wall-Mounted, Overhead. 8. Shell Protection Degree: Not Lower Than Ip40 For Indoor Installation. 9. Availability Of A Din Rail For Installing A Circuit Breaker. 10. The Presence Of A Cover That Provides Protection From Accidental Contact With Live Parts. 11.Case Color: White, Gray Or Other Manufacturers Standard Color. 12. Marking: The Name Or Trademark Of The Manufacturer, Product Model, Ip Protection Degree And Main Technical Characteristics Must Be Indicated On The Case Or Packaging. 13. The Product Must Be New, Unused, Without Mechanical Damage. Complete Set: Housing, Cover, Din Rail And Fastening Elements, If Provided For By The Product Design. To Agree With The Customer 8 705 640 87 18, Three-Phase Automatic Switch. 1.Product Type: Modular Or Similar Circuit Breaker. 2.Number Of Poles - 3. 3.Rated Operating Voltage - 400 V Ac. 4.Network Frequency: 50 Hz. 5. Response Characteristic - C. 6. Rated Breaking Capacity - Not Less Than 6 Ka. 7.Protection - Against Overload And Short Circuit Currents. 8.Mounting Method - On A Din Rail Or Other Installation Method Provided By The Manufacturer. 9.The Housing Is Made Of Electrical Insulating Material, Ensuring Safe Operation. 10.Marking - The Product Body Must Clearly Indicate The Trademark Or Name Of The Manufacturer, Product Type, Number Of Poles, Rated Current (63 A), Operating Characteristic (C), Rated Voltage And Breaking Capacity. 11. The Product Must Be New, Not Used, Without Mechanical Damage. To Agree With The Customer 8 705 640 87 18, Copper Power Cable Vvg 4×4 Mm². 1. Number Of Conductive Cores: 4. Nominal Cross-Section Of Each Core: 4 Mm². Conductor Material: Copper. Rated Voltage: 0.66 Kv Or Higher, According To Manufacturers Specifications. Core Insulation: Pvc Plastic. Outer Shell: Pvc Plastic. Purpose: For Transmission And Distribution Of Electrical Energy In Stationary Electrical Installations. To Agree With The Customer 8 705 640 87 18, 12V Power Supply For Monitors. Power Supply Type: Switching, Stabilized, With Protection Against Short Circuit, Overload, Overvoltage And Overheating. Input Voltage: 100-240 V Ac, Mains Frequency - 50/60 Hz. Output Voltage: 12 V Dc. Output Current: Not Less Than 5 A. Output Power: 60 W. The Output Connector Must Match The Power Connector Of The Monitor You Are Using. For The Standard Version, It Is Recommended To Use Connector Type: Dc Barrel. Size: 5.5 X 2.1 Mm, Polarity: Center-Plus (+), Output Cable Length: Not Less Than 1.02 M, Conductor Material: Copper, Insulation: Pvc Or Similar Material. The Kit Should Include - 1. Power Supply 12 V - 1 Pc. 2. Network Cable/Plug - 1 Pc. 3. Output Cable With Dc Connector - 1 Pc. 4. Operation Manual - 1 Pc. 5. Packaging - 1 Set. 12 Month Warranty. The Equipment Must Be New In Packaging. To Agree With The Customer - / 771 189 67 06, Fastening A Corrugated Hose With A Diameter Of 200 Mm. To Agree With The Customer 8 705 87 18, Exhaust Fan With A Diameter Of 100 Mm. To Agree With The Customer 8 705 87 18, Double-Sided Transparent Tape 48 Mm X 25 M. To Be Agreed With The Customer 8 705 87 18
Key Value
Tender Value
167,700 - KZT
Tender Documents
Global Tender Document
b8fa4104-3cff-454d-94f8-2e1382cd6ff6.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.