GTR 119727482

Request For Quotation Purchase Of Goods: Medical Products For Paid Services

ICB — International Competitive Bid Closes Oct 28, 2026 — 4 days left Central Asia
Tender Information
GTR Reference
119727482
Tendering Authority
Subscribe to view
Tender No
17848045
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Goods: Medical Products For Paid Services
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
28-10-2026 4 days left
Work Detail
Control Blood On Sysmex Xp-300 (Normal). Control Blood (Normal) To Check The Precision And Accuracy Of Hematological Analyzers For 16 Diagnostic And 6 Service Parameters. Designed For Use In Sysmex Xp-300 Hematology Analyzers, Control Blood On Sysmex Xp-300 (Low Level). Control Blood For Testing The Precision And Accuracy Of Hematological Analyzers For 16 Diagnostic And 6 Service Parameters Intended For Use In Sysmex Xp-300 Hematological Analyzers, Control Blood On Sysmex Xp-300 (High Level). Control Blood (High Level) To Test The Precision And Accuracy Of Hematology Analyzers For 16 Diagnostic And 6 Service Parameters. Designed For Use In Sysmex Xp-300 Hematology Analyzers, Washing Solution For Biochemical Analyzer Cd80 (1 L * 1) Special Concentrated Reagent. The Reagent Is Intended For Preparing A Washing Solution Used For Washing The Block Of Reaction Cuvettes, Dosing Probes, And Mixer. The Finished Solution Should Not Have Corrosive Or Oxidizing Properties When In Contact With Analyzer Parts. The Concentrate Must Be Packaged In At Least 1 Liter. There Should Be Enough To Prepare At Least 15 Liters Of Cleaning Solution. Compatible With Bs-240Pro Closed System Chemistry Analyzers, Multicontrol Level 2, 6X5 Ml Lyophilized Serum For Qc, With Certified Values ​​(P) For The Determined Lipid Analytes: Alb; Alp; Alt; Amy; Ast; Db-Dsa; Db-Vox; Tb-Dsa; Tb-Vox; Ca; Tc; Ck; Crea-S; Glu-Hk; Glu-O; Ggt; Hbdh; Iga; Igg; Igm; Ldh; Mg; P; Tp; Tg; Urea; Ua; Fe; Che; Lip; Na+; K+; Cl-; C3; C4; Crp; Hs-Crp; Hdl-C; Ldl-C; Apo-A1; Apo-B; Pa; Ck-Mb; Aso; Trf; Fer; Uibc By Direct Photometry Without Deposition. When Diluting Lyophilic Serum, The Volume Of The Finished Control Solution Is At Least 30 Ml. The Control Serum Kit Must Be Equipped With A Special Barcode Compatible With The Analyzer’S Built-In Scanner To Automatically Read Reference Test Values ​​Into The Analyzer’S Memory. Compatible With Bs-240Pro Closed System Chemistry Analyzers, Multicontrol Level 1, 6X5 Ml Lyophilized Serum For Qc, With Certified Values ​​(N) For The Determined Analytes: Alb; Alp; Alt; Amy; Ast; Db-Dsa; Db-Vox; Tb-Dsa; Tb-Vox; Ca; Tc; Ck; Crea-S; Glu-Hk; Glu-O; Ggt; Hbdh; Iga; Igg; Igm; Ldh; Mg; P; Tp; Tg; Urea; Ua; Fe; Che; Lip; Na+; K+; Cl-; C3; C4; Crp; Hs-Crp; Hdl-C; Ldl-C; Apo-A1; Apo-B; Pa; Ck-Mb; Aso; Trf; Fer; Uibc By Direct Photometry Without Deposition. When Diluting Lyophilic Serum, The Volume Of The Finished Control Solution Is At Least 30 Ml. The Control Serum Kit Must Be Equipped With A Special Barcode Compatible With The Analyzer’S Built-In Scanner To Automatically Read Reference Test Values ​​Into The Analyzer’S Memory. Compatible With Bs-240Pro Closed System Chemistry Analyzers, Multicalibrator Single-Level Multicalibrator For One-Component And Two-Component Tests. Freeze-Dried Serum With Certified Analyte Values ​​For Test Calibration: Got/Alt, Got/Ast, Alb, Ams, Ggt, Glu-Godpap, Fe, Crea-J, Ldh, Mg, Bun/Urea, Tp, Tbil/Vox, Dbil/Vox, Chol/Tc, Tg, Alp, Ua. When Diluting Lyophilic Serum, The Volume Of The Finished Calibrator Is At Least 30 Ml. The Multicalibrator Kit Must Be Equipped With A Special Barcode Compatible With The Analyzer’S Built-In Scanner To Automatically Read Reference Test Values ​​Into The Analyzer’S Memory. Compatible With Bs-240Pro Closed System Chemistry Analyzers, Alkaline Phosphatase Two-Component Reagent Kit For The Determination Of Alp. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel. Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 942 Studies, D-Dimer Control (D-Dimer) 1×2 Levels×0.5 Ml 2 Levels×0.5 Ml, Creatinine Two-Component Reagent Kit For Determination Of Crea-S. Sarcosine Oxidase Method. The Volume Of The Working Solution Is At Least 72 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel. Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 366 Studies, Iron With Calibrator And Control Two-Component Set Of Reagents For The Determination Of Fe. The Volume Of The Working Solution Is At Least 96 Ml. Reagents Must Be Packaged In Original Disposable Containers R1 And R2 + Calibrator 1X1.5 Ml To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel.Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 483 Studies, Glucose Two-Component Reagent Kit For The Determination Of Glu-Godpap. The Volume Of The Working Solution Is At Least 200 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel. Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 822 Studies, Aspartate Aminotransferase Two-Component Reagent Kit For Got/Ast Determination. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carouselcompatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 942 Studies., Alpha Amylase. Two-Component Reagent Kit For Ams Determination. The Volume Of The Working Solution Is At Least 48 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel. Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 242 Studies, Albumin Set. One-Component Reagent Kit For The Determination Of Alb. The Volume Of The Working Solution Is At Least 160 Ml. The Reagent Must Be Packaged In Original R1 Disposable Containers To Prevent Contamination And Does Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel/Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 728 Studies, Alanine Aminotransferase. Two-Component Reagent Kit For Got/Alt Determination. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel/Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 942 Studies, Test Kit For Determining Pct. Quantitative Determination Of Pct (25 Pieces), Microcentrifuge Tube, Eppendorf Type, 2 Ml. 500 Pcs/Pack, D-Dimer R1:1×40 Ml+R2:1×15 Ml+Calibrator:6×0.5 Mlr1:1×40 Ml+R2:1×15 Ml+Calibrator:6×0.5 Ml, Specific Protein Calibrator 5X1 Ml (C3, C4, Crp, Iga, Igg, Igm) 5 Ampoules Of 1 Ml
Key Value
Tender Value
5,786,661 - KZT
Tender Documents
Global Tender Document
c37ec38d-b161-403e-8f4e-071a75944d1f.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,