GTR 119580011
Request For Quotation Purchase Of Goods: Medical Products For Paid Services
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
119580011
Tendering Authority
Subscribe to view
Tender No
17792926
Financer Name
Self-Funded
Work Title
Request For Quotation Purchase Of Goods: Medical Products For Paid Services
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
22-10-2026
Closed
Work Detail
Specific Protein Calibrator 5X1 Ml (C3, C4, Crp, Iga, Igg, Igm) 5 Ampoules Of 1 Ml, C-Reactive Protein R-1 1*40 Ml, R-2 1*10 Ml. (Srb) (Nephelometry Method) 1X40 +1X10, Lactate Dehydrogenase R1: 4X35 Ml + R2: 2X18 Ml. (Ldh) (Kinetic, Uv Method) (Ifcc) 4Х35 +2Х18, Total Cholesterol One-Component Reagent Kit For The Determination Of Chol/Tc. The Volume Of The Working Solution Is At Least 160 Ml. The Reagent Must Be Packaged In The Original R1 Disposable Container To Prevent Contamination And Does Not Require Transfer To An Additional Cartridge. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel. Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 728 Studies, Direct Bilirubin Two-Component Reagent Kit For The Determination Of Dbil/Vox. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel.Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 824 Studies, Total Bilirubin Two-Component Reagent Kit For The Determination Of Tbil/Vox. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carouselcompatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 824 Studies, Total Protein Kit One-Component Reagent Kit For The Determination Of Tp. The Volume Of The Working Solution Is At Least 160 Ml. The Reagent Must Be Packaged In The Original R1 Disposable Container To Prevent Contamination And Does Not Require Transfer To An Additional Cartridge. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel. Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 1428 Studies, Urea Kit Two-Component Reagent Kit For The Determination Of Bun/Urea. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel. Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 600 Studies, Creatinine Two-Component Reagent Kit For Determination Of Crea-S. Sarcosine Oxidase Method. The Volume Of The Working Solution Is At Least 72 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel. Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 366 Studies, Iron With Calibrator And Control Two-Component Set Of Reagents For The Determination Of Fe. The Volume Of The Working Solution Is At Least 96 Ml. Reagents Must Be Packaged In Original Disposable Containers R1 And R2 + Calibrator 1X1.5 Ml To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carrying Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel.Compatible With Bs-240Pro Closed System Biochemical Analyzers. The Set Is Designed For At Least 483 Studies, A Set Of Reagents For Determining The Activated Partial Thromboplastin Time Aptt Test (100-200 Opr). Set Of Reagents For Determining Activated Partial Thromboplastin Time Based On Kaolin, A Set Of Reagents For Determining The Concentration Of Fibrinogen In Blood Plasma Tech-Fibrinogen-Test (100-200 Opr). Tech-Fibninogen-Test The Kit Is Designed For Rapid Quantitative Determination Of Fibrinogen Content In Blood Plasma (Chronometric Method According To Clauss) On A Coagulometer., Set Of Reagents For Determining Thrombin Time Thrombo Test (100-200 Opr). Thrombo Test The Kit Is Designed To Determine Thrombin Time In The Diagnosis Of End-Stage Coagulation Disorders., Set Of Reagents For Determining Prothrombin Time Tehplastin-Test (100 Samples). The Techplatin Test Is Designed To Assess Prothrombin Clotting Time. The Measurement Is Carried Out Using A Coa Gulometer Or Manually. Determination Of Prothrombin Time Is Used To Test Factors Of The Prothrombin Complex (Ii - Prothrombin, V, Vii, X) And Monitor Anticoagulant Treatment, A Set Of Reagents For The Analysis Of Cerebrospinal Fluid. The Set Of Reagents Allows You To Determine Cytosis, Qualitative And Quantitative Determination Of Total Protein, And Qualitative Determination Of Globulins In The Cerebrospinal Fluid. Designed For Analysis Of 200 Samples.Set Contents:Samsons Reagent, 10 Ml - 1 Fl.Phenol, 2.5 G – 1 Fl.Sulfosalicylic Acid 2-Water, 30 G – 1 Packagesodium Sulfate, 70 G – 1 Packagetotal Protein Calibration Solution, 5 Ml - 1 Vial.Ammonium Sulfate, 85 G – 1 Packet., Azur-Eosin Dye According To Romanovsky. Azur-Eosin Dye According To Romanovsky Is A 0.25% Solution Of Dry Dye Eosin Methylene Blue According To Romanovsky In Methanol, 1 Bottle (1 L).1 Liter Of Dye Is Designed For Fixation Of 1000 Blood Smears And For Fixation With Coloring From 450 To 1000 Smears.Principle Of The Methodthe Staining Method Is Based On The Fact That As A Result Of Interaction With The Dye, The Formed Elements Of The Blood Acquire A Specific Color And This Makes It Possible To Calculate Their Quantity., Dye-Fixer Eosin Methylene Blue According To May-Grunwald. The Fixative Dye Eosin Methylene Blue According To May-Grunwald Is A 0.25% Solution Of Dry Dye Eosin Methylene Blue According To May-Grunwald In Methanol, 1 Bottle (1 L).1 Liter Of Fixative Dye Is Designed For Fixation Of 1000 Blood Smears And For Fixation With Coloring From 450 To 1000 Smears.Principle Of The Methodthe Fixation Method Is Based On The Fixation Of Blood Cells, Which, Causing Protein Coagulation, Leads To The Attachment Of The Drug To The Glass.The Staining Method Is Based On The Fact That As A Result Of Interaction With The Dye, The Formed Elements Of The Blood Acquire A Specific Color And This Makes It Possible To Calculate Their Quantity., Control Blood On Sysmex Xp-300 (Normal). Control Blood (Normal) To Check The Precision And Accuracy Of Hematological Analyzers For 16 Diagnostic And 6 Service Parameters. Designed For Use In Sysmex Xp-300 Hematology Analyzers, Control Blood On Sysmex Xp-300 (Low Level). Control Blood For Testing The Precision And Accuracy Of Hematological Analyzers For 16 Diagnostic And 6 Service Parameters Intended For Use In Sysmex Xp-300 Hematological Analyzers, Control Blood On Sysmex Xp-300 (High Level). Control Blood (High Level) To Test The Precision And Accuracy Of Hematology Analyzers For 16 Diagnostic And 6 Service Parameters. Designed For Use In Sysmex Xp-300 Hematology Analyzers
Key Value
Tender Value
8,312,294 - KZT
Tender Documents
Global Tender Document
42049d16-72ce-4a63-9851-9d87d4830d67.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.