GTR 118282753
Request For Quotation Equipment For The Use Of Alarm Devices In Fire Conditions
ICB — International Competitive Bid
Closes Sep 22, 2026
— 2 days left
Central Asia
Tender Information
GTR Reference
118282753
Tendering Authority
Subscribe to view
Tender No
17652712
Financer Name
Self-Funded
Work Title
Request For Quotation Equipment For The Use Of Alarm Devices In Fire Conditions
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
22-09-2026
2 days left
Work Detail
Cable For Installation Of Alarm Systems And Telecommunication Systemsshell Materialpvc Plastic Compoundinsulation Materialpolyethylenegosttu 3581-001-39793330-2000Core Diameter, Mm0.5Additional Informationthe Core Is Single-Wire Copper. Cable Diameter: 2.9X2.2 Mm Cost Includes Installation And Connection Work, Switching Device Uk-Vk For Use In Fire Alarm Systems To Transmit The Starting Impulse To Fire Control Devices. Device Design Number Of Switching Channels Relay Contact Characteristicsuk-Vk Isp.10 2 Normally Open, Short Circuituk-Vk Isp.11 1Uk-Vk Isp.12 2 Normally Closed, For Switchinguk-Vk Isp.13 1Uk-Vk Isp.14 2Uk-Vk Isp.15 1Characteristics Of Executive Relays:Device Version Max. Switching Voltage*, V Max. Switched Current*, Avariable Constant Variable Constantuk-Vk Version 10Uk-Vk Isp.11 250 30 5 5Uk-Vk Isp.12Uk-Vk Isp.13Uk-Vk Isp.14Uk-Vk Isp.15 250 30 10 10Note: * - For One Channelcontrol Signal Characteristics:Device Design Control Voltage*, V Control Current*, Auk-Vk Isp.10 10-14 0.028 – 0.038Uk-Vk Isp.11Uk-Vk Isp.12Uk-Vk Isp.13Uk-Vk Isp.14 20 – 27.6 0.014 – 0.019. Price Includes Installation And Connection Work, Cabinet With A Redundant Power Supply For Installation Of Fire Automatic Equipment Shps-24 Version 10. Number Of Power Inputs 2Main Power Source Single-Phase Ac Mains With Rated Voltage 230 V, Frequency 50/60 Hzbackup Power Supply Rechargeable Batteries Of The Bolid Series Ab1217s Or Ab1217m – 2 Pcs.Rated Output Voltage: When Powered From The Mains (27.2±0.6) Vwhen Powered By Batteries (19…27) Vrated Total Load Current 2 Athe Total Number Of 24 V Voltage Outputs For Connecting Devices Installed Inside Shps 7Maximum Current For One Output 24 V 0.4 Amaximum Power Consumed From The Network At A Voltage Of 220 V And Rated Load Current (Excluding Consumption By Additional Consumers), No More Than 120 Vathe Total Number Of Rs-485 Outputs For Connecting Interface Lines Installed Inside Shps 7Number Of Isolated Rs-485 Interfaces For Connecting External Devices 2Length Of The Rs-485 Interface Line To Each Of The Devices Inside The Shps, No More Than 10 Mlength Of Lines Of Isolated Rs-485 Interfaces At An Operating Speed Of 9600 Bit/S, No More Than 3000 Melectrical Insulation Strength Between Isolated Interface Lines, As Well As Between Isolated Interface Lines And Other Circuits, Not Less Than 500 V, 50 Hzoverall Dimensions, No More Than 650×500×220 Mmcabinet Weight (With Batteries), No More Than 30 Kgthe Degree Of Protection Provided By The Shell Is Ip41. It Is Possible To Install The Mk-1 Mounting Kit. The Price Includes Installation And Connection Work, The Display Units Are Designed For Joint Use With A Network Controller (Control And Fire Control Panel S2000m To Provide Light And Sound Indication Of The State Of The Fire Alarm Sections. Dc Supply Voltage 10.2 ... 28.4 Vcurrent Consumption:- In Standby Mode (All Indicators Are Off, Unit Power Supply Is 12 V / 24 V)- In Emergency Mode (12 V Unit Power Supply)- In Emergency Mode (24 V Unit Power Supply)No More Than 50 Mano More Than 200 Mano More Than 100 Manumber Of Power Inputs 2The Units Technical Readiness Time For Operation Is No More Than 5 Snumber Of Sections 60Shell Protection Degree According To Gost 14254-2015 Ip20climatic Version According To Ost 25 1099-83 O3operating Temperature Range Minus 30 To +50 °Crelative Humidity At +40 °C No More Than 93%Resistance To Mechanical Stress According To Ost 25 1099-83 Placement Category 3Vibration Loads:- Frequency Range- Maximum Acceleration1…35 Hz0.5 Goverall Dimensions 340X170x27 Mmblock Weight No More Than 0.6 Kgelectrical Insulation Resistance Of Circuits (Under Normal Conditions According To Gost R 52931-2008) Not Less Than 20 Mohmaverage Time Between Failures In Standby Mode Is At Least 40,000 Hoursprobability Of Failure-Free Operation In 1000 Hours 0.98758Average Service Life 10 Yearsaverage Time To Restore Functionality (Excluding Delivery Of Spare Parts) No More Than 30 Minutes; Cost Includes Installation And Connection Work, Information Boardluxinstallationindoorstype Of Informationtext Datadisplayed Informationstaticproduct Dimensions (L X W X H), Mm300, 100 Cost Includes Installation And Connection Work, Type Of Cable Productcablenumber Of Cores4section, Mm20.2Core Materialcoppershell Materialpvc Plastic Compoundgostyescore Diameter, Mm0.5Length, M1 Price Includes Installation And Connection Work, The Addressable Alarm And Trigger Block Is Designed For Operation As Part Of Fire Alarm, Warning And Evacuation Control Systems, Fire Automatics. Used With The S2000-Kdl Controller. Controlled Outputs 2Maximum Switching Current Of One Relay 3 Aswitching Voltage (From Unit Power Supply) From 10.2 V To 28.4 Vmaximum Circuit Monitoring Current 1.5 Macurrent Consumption From The Power Source Excluding The Consumption Of Actuators, No More At A Supply Voltage Of 12 V - 60 Maat Supply Voltage 24 V - 35 Mafrom The Power Supply In Standby Mode (All Outputs Are Turned Off), No More Than At A Supply Voltage Of 12 V - 25 Maat Supply Voltage 24 V - 15 Mafrom Dpls, No More Than 1 Maoperating Voltage: - Executive Part From 10.2 V To 28.4 V- Transmitting And Receiving Part 8...10.2 V Dplsgalvanic Isolation Of Dpls And Power Supply Power Unit Up To 4 Kvtamper Sensor Microswitchtechnical Readiness Time No More Than 15 Soperating Temperature Range From Minus 30 To +55°Crelative Humidity Up To 93% At +40°Chousing Protection Degree Ip40overall Dimensions 102X107x39 Mmweight No More Than 0.2 Kgprogramming Program Uprog.Exemounting Type: Wall Mounted Or Din Rail Mounting And Connection Work Included In Price, The Annunciator Is Designed For Light And Sound Notification Of The Condition Of An Object Protected By Fire Alarm Devices.Type Light, Soundnumber Of Channels2line Signal Playback Volume, Ma50 Maproduction Time14 Daysequipmentpassport, Packagingadditional Informationline Type - Warning Lineproduct Dimensions (L X W X H), Mm100, 80, 42 The Price Includes Installation And Connection Work, Typefire Detectordegree Of Protectionip40installation Methodwall Mountedcolorredoperating Temperature Range, ºс-30 To +55°Cdetector Current Consumption From Als, Ma0.5Housing Materialplasticproduct Dimensions (L X W X H), Mm95, 91, 34 Cost Includes Installation And Connection Work, Two-Wire Communication Line Controller, Used In Systems: Fire Alarm. Number Of Connected Aus 127The Length Of The Two-Wire Line Is 1200 Meters With A Cross-Section Of 1.5 Mm²600 Meters With A Cross Section Of 0.75 Mm²400 Meters With A Cross Section Of 0.5 Mm²160 Meters With A Cross Section Of 0.2 Mm²supply Voltage 10.2 V To 28.4 V Dccurrent Consumption (Excluding Ac Consumption), No More: At Supply Voltage 12 V 80 Maat Supply Voltage 24 V 40 Macurrent Consumption In Standby Mode (127 Au Are Connected With A Current Consumption Of 0.5 Ma Each), No More Than: At A Supply Voltage Of 12 V 160 Maat Supply Voltage 24 V 80 Maexternal Electronic Identifier (Ei) Reader 1 Inputinterface For Connected Dallas Touch Memory(1-Wire, Μ-Lan), Wiegand And Aba-Track Ii Readerscontrol Of Reader Leds Control Of Two Reader Leds (Red And Green) In Accordance With The “+5V Cmos” Logic Levels, With Current Limitation When Directly Connecting The Leds At 10 Mareader Sound Signal Control Yes. Control Signal +5V Cmosmemory Capacity Of Touch Memory(Ibutton) Keys, Cards Or Codes 512Non-Volatile Event Buffer 512Light Indication On The Front Panel 3 Led Indicators (Operation, Rs-485 And Dpls)Microcontact Housing Tamper Sensorcommunication Port (For Work In Iso Orion) Rs-485, Orion Protocolpower Supply Of The Device From An External Dc Source (There Is An Additional Input For Connecting A Backup Power Source)Ready For Work After Turning On The Power No More Than 15 Soperating Temperature Range From Minus 30 To +55°Crelative Humidity Up To 98% At +25°Chousing Protection Degree Ip40overall Dimensions 156×107×39 Mmdevice Weight No More Than 0.3 Kgprogramming The Controller Using The Uprog.Exe Programconnecting To A Pc Via Rs-485 Interface Using An Interface Convertermounting Type: Wall Mounted Or Din Rail. The Price Includes Installation And Connection Work, Redundant Power Supply. Input Voltage, V13 To 14.2 Voutput Voltage, V13.6 Voutput Current, A4. Price Includes Installation And Connection Work, Cable Channel 25X25. Degree Of Protection Ipip20materialpvc Plastic Cost Includes Installation And Connection Work, Control And Start-Up Unit For Operation As Part Of Centralized Fire Alarm Systems, Fire Extinguishing Control, Access Control And Video Monitoring For Controlling Actuators And Monitoring Control Circuits. Controlled Outputs 6 Pcsswitching Voltage (From Unit Power Supply) 10.2 Vdc To 28.4 Vdcmaximum Switching Current Of One Channel 2.5 Amaximum Switching Current Of The Unit 6 Amaximum Circuit Monitoring Current 1.5 Manumber Of Radial Non-Addressed Technological Alarm Loops (Al) 2Resistance Of Al Wires Without Taking Into Account The Remote Element, No More Than 100 Ohmsleakage Resistance Between Al Wires Or Each Wire And Ground, Not Less Than 50 Kohmmax. Total Loop Resistance 50 Kohmbuilt-In Sound Alarm Notamper Sensor Microswitchcommunication Port (For Work In Iso Orion) Rs-485, Orion Protocolnumber Of Rs-485 Lines 2Powering The Device From An External Dc Source (There Is An Additional Input For Connecting A Backup Power Source)Supply Voltage 10.2 V To 28.4 V Dccurrent Consumption (Excluding Consumption Of Actuators), No More At Supply Voltage 12 V 130 Maat Supply Voltage 24 V 130 Macurrent Consumption In Standby Mode (All Outputs Are Turned Off), No More Than At A Supply Voltage Of 12 V 75 Maat Supply Voltage 24 V 45 Maready For Work After Turning On The Power No More Than 3 Soperating Temperature Range From Minus 30 To +55 °Crelative Humidity Up To 98% At +25 °Chousing Protection Degree Ip40overall Dimensions 156X107x39 Mmdevice Weight No More Than 0.3 Kgdevice Programming Program Uprog.Execonnecting To A Pc Via Rs-485 Interface Using An Interface Convertermounting Type: Wall Mounted Or Din Rail Mounting And Connection Work Included In Price
Key Value
Tender Value
1,615,965 - KZT
Tender Documents
Global Tender Document
f99caa85-2d94-4c8e-8191-1c5dbac8fe41.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.