GTR 118182662

Request For Quotation Purchasing Accessories For The Heating Season (Please Read The Technical Specifications Carefully)

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
118182662
Tendering Authority
Subscribe to view
Tender No
17635185
Financer Name
Self-Funded
Work Title
Request For Quotation Purchasing Accessories For The Heating Season (Please Read The Technical Specifications Carefully)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
18-09-2026 Closed
Work Detail
Rvo-10 - Valve-Type Single-Pole Arrester For Voltage Class 10 Kv, Boiler, Water Heating, Gas Floor, No More Than Kva 174 Lv/Gn (Vv 1535), Operating Pressure -0.35 Mpa, Maximum Temperature - 85 Degrees, Heating Capacity - 174 Kw, With Burner (Voltage - 220V, 50Hz - Frequency, 1F - (Single-Phase Current)), Boiler, Water-Heating, Floor-Standing, Gas, No More Than Working Pressure - 0.35 Mpa. Max. Temperature -85°C, Heat Producer 116 Kw, With Burner (Supply Voltage 220 Volts, Power Frequency 50 Hz, 1Φ Single-Phase Current), Immersion Protective Sleeve (Thermowell) For Boiler Temperature Sensor. Body Material: Copper (Longest Blind Tube). Threaded Head Material: Brass. (Copper Tube Is Securely Soldered Into A Brass Plug With External Thread) The Head Has A Hexagonal Shape For A 22Mm Wrench. Product Length 11 Cm. Cut Aa. Thread 1/2 Inch (Cylindrical Pipe). Copper Tube With A Diameter Of 16 Mm, Wall Thickness 0.5 Mm. Pressure Seal/Tight Plug., High-Voltage Fuse Pkt-101-10-8-40-U1, Rated Voltage 10 Kv, Rated Current 8 A, Rated Shutdown Current 40 Ka., Single-Phase Electronic Meter. 2-Wire. Accuracy Class -1.0. Voltage: 230V, 50Hz. Current: 5(60)A - Suitable For Loads Up To 13-15 Kw. Type: Single-Tariff / Multi-Tariff. Screen: Liquid Crystal, Shows Kwh. Single-Phase: 4 Terminals For Wires (2 Input, 2 Output)., High-Voltage Fuse Pkt-101-10-16-63-U1, Rated Voltage 10 Kv, Rated Current 16 A, Rated Shutdown Current 63 Ka., High-Voltage Fuse Pkt-101-10-20-100-U1, Rated Voltage 10 Kv, Rated Current 20 A, Rated Shutdown Current 100 Ka., Three-Phase Electricity Meter. Rated Voltage: 3X230/400V - Designed For Operation In Four-Wire Networks With A Linear Voltage Of 400 V And Phase Voltage Of 230 V. Base (Nominal) Current: 10 A. Maximum Current: 100 A. Network Frequency: 50 Hz. Meter Constant (Pulse Output): 400 Imp/(Kw H) - For One Kilowatt-Hour Of Recorded Energy, The “Network” Led Makes 400 Flashes. Accuracy Class: 1 (Indicated In A Circle On The Panel) - For Commercial Electricity Metering. Display: Liquid Crystal Indicator (Lcd) For Displaying Readings. Number Of Tariffs: Single Tariff Metering Device. Housing Type: P32 - Compact Housing Designed For Universal Installation (Both On A Standard Din Rail And On A Mounting Panel In A Shield Using Three Screws). Protection From External Influences: Equipped With A Built-In Magnetic Field Sensor (Indicator On The Panel With A Magnet Icon), Recording Attempts Of Unauthorized Influence On The Device., Circulation Pump. Power:220-230V/50Hz; Housing Material: Cast Iron Pump Part And Aluminum Motor Housing. Max. Head:8M; Max.Flow: 170L/Min; Degree Of Protection: Ip 44; Insulation Class:H; Temperature Class: Tf 110; Power Consumption By Speed: I Speed (145 W), Ii Speed (220 W), Iii Speed (245 W), Energy Efficiency: Class B; Rotor Type: Wet., Circulation Pump, Connection Type - Flange (Nominal Flange Diameter Dn 50), Three-Phase, Current Frequency - 50 Hz (With Support For Changing Rotation Speeds), 380-400V, Rotor Type - Wet, Temperature Class - Tf120s1, Electrical Protection Class - Ip44, Class H, Installation Length: 280 Mm, Maximum Operating Pressure: Up To 10Bar(1000Kpa), Boiler, Hot Water, Gas Wall-Mounted, With A Hot Water Circuit, Boiler Type (With A Closed Combustion Chamber And Forced Smoke Removal), Thermal Power - Max. 35.0 Kw, Min. - 14.0 Kw. Efficiency: 91.5%, Maximum Temperature: 80 °C; Max. Pressure In The Heating System: 3.0 Bar; Max. Hot Water Pressure (Dhw): 8.0 Bar; Gas Pressure - 13 Mbar; Power Consumption - 150 W. Voltage/Frequency - 220 V, 50 Hz. Includes Chimney Pipe, Vacuum Pump, Booster, With Dry-Running Protection, Equipment Type: Water Pump; Network Voltage - 220V; Current Frequency - 50 Hz, Current Consumption: 7.0 A; Net Power - 1.1 Kw; 1.5 Hp; Power Consumption: 12 Kw; Capacitor Parameters: 25 Μf; Maximum Productivity (Q.Max):90L/Min; Maximum Head:48 Meters; Minimum Pressure: 6 Meters; Maximum Suction Depth: 9 Meters; Diameter Of Inlet And Outlet Holes: 1 X 1; Maximum Liquid Temperature: 40 °C; Insulation Class: B(I.C.L.B); Protection Class: Ip44; Engine Rotation Speed: 3000 Rpm; Operating Mode: Continuous; Additional Protection: Built-In Thermal Protection., Wire For Ignition Of The Burner, High-Voltage, Copper, Stranded, 1 Meter. Temperature 200-300°C. On One Side There Is A Cap For The Spark Plug/Electrode, On The Other There Is A Cap For The Bolt. Insulation: Silicone Rubber, Haplog-Free, Heat-Resistant. Core: Copper, Sometimes With Anti-Interference Braiding., Outdoor Installation Disconnector Rlnd-10 Kv/400 A, Type Of Installation - Outdoor, Rated Current - 400 A, Voltage - 10 Kv, With Prnz, Inverter Boost Pump, Network Voltage: 220W; Connector Diameter: 25Mm; Throughput: Q (M3/H): 6; Allowable Water Temperature: Up To 80 °C; Maximum Pressure H(M): 53; Power Consumption: 1100Bt (High Power - Lifting Height Up To 8.5 Meters In 2 Minutes. The Engine Automatically Adjusts The Required Power. Allows You To Maintain The Desired Range Of Water Pressure, Regardless Of The Number Of Simultaneously Open Water Intake Points. Wide Voltage Range - From 180 Up To 260V. Ultra-Low Noise Level. Easy To Operate: Set The Required Pressure, And The Pump Will Automatically Adjust Its Operation, Maintaining The Specified Pressure Range. All Faults Are Displayed On The Screen., Check Valve, Brass, With Spring, With Filter With Internal Thread, Nrv Ef Nrv Ef Is A Threaded Check Valve. The Coolant Used With The Valve Is Water Or Water-Glycol Mixtures Up To 50% With Temperatures Up To 110 °C. With Diameters 25 Mm And Nominal Pressure Pn 25 Bar, Ignition Electrode (Ignition Electrode), For Gas, Liquid Fuel Or Combined Burners Of Heating Boilers. The Part Is Part Of The Automatic Boiler Start System. Its Main Task Is To Create A Powerful Electric Spark. A High-Voltage Transformer Supplies Current To The Electrode Through A Special Cable. The Current Passes Through An Internal Metal Rod. A Strong Spark Discharge Is Formed At The Curved Open End (Tip), Which Instantly Ignites The Air-Fuel Mixture In The Combustion Chamber Of The Burner. Part Characteristicsceramic Body (White Part): Serves As A High-Strength Insulator. Ceramics Have Increased Heat Resistance And Dielectric Strength, Preventing Sparks From Reaching The Burner Body In The Wrong Place. Metal Rod: Made Of Specialized Heat-Resistant Alloys (Often Kanthal), Resistant To Constant Exposure To Open Flames And Oxidation. Contact Group (Lower Metal Fitting): Designed For Quick And Reliable Connection Of The High Voltage Ignition Cable. The Working Tip, Bent At An Angle Of 90 Degrees, Is Designed Specifically For Strict Positioning Of The Spark Gap Relative To The Nozzle Or Divider Burners. The Outer Part Of The Ceramic Often Has A Diameter Of 8 To 11 Mm.
Key Value
Tender Value
7,253,550 - KZT
Tender Documents
Global Tender Document
4610e40c-5f70-4e0a-966e-43b22c0955e2.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you