GTR 117820721

Request For Quotation Purchasing Household Goods

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
117820721
Tendering Authority
Subscribe to view
Tender No
17575385
Financer Name
Self-Funded
Work Title
Request For Quotation Purchasing Household Goods
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
09-09-2026 Closed
Work Detail
- Number Of Poles: 3 (Three-Pole)- Rated Operating Current (In): Strictly 50 A- Housing Type: Block, In A Molded Housing Made Of Dielectric Plastic That Does Not Support Combustion.- Release Type: Thermal (For Overload Protection) And Electromagnetic (For Instantaneous Short Circuit Protection).- Rated Operating Voltage (Ue): No Less Than 400 V Ac (Frequency 50 Hz).- Rated Insulation Voltage (Ui): Not Less Than 690 V.- Rated Ultimate Breaking Capacity (Icu): Not Less Than 10 Ka (Kiloamperes) At A Voltage Of 400 V.- Instantaneous Setting Current (Ii): Not Less Than 500 A.2. Requirements For Design, Dimensions And Compatibility (Justification Of Equivalence According To Va57f35):- Due To The Need To Install The Machine In The Existing Installation Space Of The Power Cabinet (Msb), The Overall Dimensions Of The Supplied Product Should Not Exceed The Following Values: Width - No More Than 115 Mm, Height - No More Than 175 Mm, Depth - No More Than 135 Mm (Corresponds To The Dimensions Of The Va57f35 Series).- Installation/Installation Method: Stationary, On The Mounting Panel.- Direction Of Connection Of External Conductors: Forward.3. Quality, Certification And Completeness:- The Product Must Be New, Not Used, Not Refurbished, Year Of Manufacture - No Earlier Than 2025-2026. The Product Body Must Be Intact, Without Cracks, Chips Or Traces Of Installation.- The Delivery Set For Each Device Must Include: Interpolar Dielectric Partitions (At Least 2 Pcs.), A Set Of Mounting Screws, The Original Product Passport With A Mark From The Manufacturer’S Quality Control Department And An Instruction Manual.- The Supplier Is Obliged To Provide A Valid Certificate Of Conformity Or Declaration Of Compliance With The Requirements Of The Technical Regulations Of The Customs Union (Eaeu): Tr Cu 004/2011 “On The Safety Of Low-Voltage Equipment”.- The Warranty Period For The Supplied Goods Must Be At Least 12 Months From The Date Of Signing The Acceptance Certificate On The Government Procurement Portal., 1. Technical And Functional Characteristics: Number Of Poles: 3 (Three-Pole). Rated Operating Current (\(I_{N}\)): Strictly 100 A. Housing Type: Block, In A Molded Housing Made Of Dielectric Plastic That Does Not Support Combustion. Type Of Release: Thermal (Overload Protection) And Electromagnetic (Instantaneous Short-Circuit Protection Short Circuits). Rated Operating Voltage (\(U_{E}\)): Not Less Than 400 V Ac (Frequency 50 Hz). Rated Insulation Voltage (\(U_{I}\)): Not Less Than 690 V. Rated Ultimate Breaking Capacity (\(I_{Cu}\)): Not Less Than 10 Ka (Kiloamperes) At A Voltage Of 400 V. Instantaneous Trip Setting Current (\(I_{I}\)): Not Less Than 1000 A (This Is The Factory Setting Of Keaz For A Nominal Value Of 100A).2. Requirements For Design, Dimensions And Compatibility: Due To The Need To Install The Product In The Existing Limited Space Of The Distribution Cabinet, The Overall Dimensions Of The Supplied Device Must Not Exceed The Following Values: Width - No More Than 115 Mm, Height - No More Than 175 Mm, Depth - No More Than 135 Mm. Installation/Mounting Method: Stationary, On A Mounting Panel. Direction Of Connection Of External Conductors: Front.3. Quality, Certification And Completeness: The Product Must Be New, Not Used, Not Refurbished, Year Of Manufacture - No Earlier Than 2025–2026. The Product Body Must Be Intact, Without Cracks, Chips Or Traces Of Installation. The Delivery Package For Each Device Must Include: Interpolar Dielectric Partitions (At Least 2 Pcs.), A Set Of Mounting Screws, The Original Product Passport With A Mark From The Manufacturer’S Quality Control Department And An Instruction Manual. The Supplier Must Provide A Valid Certificate Of Conformity Or A Declaration Of Compliance With The Requirements Of The Technical Regulations Of The Customs Union (Eaeu): Tr Cu 004/2011 On The Safety Of Low-Voltage Equipment. The Warranty Period For The Supplied Goods Must Be At Least 12 Months From The Date Of Signing The Acceptance Certificate On The Government Procurement Portal., Number Of Poles: 3 Rated Operating Current 40 A. Housing Type: Block Power Circuit Breaker In A Molded Case Made Of Dielectric Material. Type Of Release: Combined - Thermal (For Protection Against Overload Currents) And Electromagnetic (For Protection Against Short Circuit Currents). Rated Operating Voltage Is At Least 400 V Ac (Frequency 50 Hz). Rated Insulation Voltage Is At Least 400 V. Rated Ultimate Breaking Capacity: Not Less Than 6 Ka (Kiloamperes) At A Voltage Of 400 V. Setting Of Short-Circuit Current Releases (Cut-Off): Fixed, With A Value Of 12 (A Characteristic Factory Parameter Of Keaz To Ensure Safe Shutdown).2. Requirements For Design, Dimensions And Compatibility: Due To The Need To Install The Product In The Existing Strictly Limited Space Of The Distribution Cabinet (To Replace Outdated Equipment Of The Ae Series) And The Exact Match Of The Mounting Holes, The Overall Dimensions Of The Supplied Device Must Not Exceed The Following Values: Width - No More Than 75 Mm, Height - No More Than 207 Mm, Depth - No More Than 120 Mm (These Are Unique Elongated Dimensions Of Keaz Ae2046, An Analogue Of A Different Size Will Not Physically Fit On The Busbars). Installation/Installation Method: Stationary, Fastening To The Mounting Panel With Screws. Direction Of Connection Of External Conductors: Front. Availability Of Drive: Manual, Lever Type. 3. Quality, Certification And Completeness: The Product Must Be New, Not Used, Not Refurbished, Produced No Earlier Than 2025–2026. The Product Body Must Be Intact, Without Cracks, Casting Defects Or Traces Of Installation. The Delivery Package For Each Device Must Include: Fastening Elements, The Original Product Passport With A Mark From The Manufacturer’S Quality Control Department And An Instruction Manual. The Warranty Period For The Supplied Goods Must Be At Least 12 Months From The Date Of Signing The Acceptance Certificate On The Government Procurement Web Portal., Number Of Poles: 3 (Three-Pole). Rated Operating Current (\(I_{N}\)): Strictly 80 A. Housing Type: Block, In A Molded Housing Made Of Dielectric Plastic That Does Not Support Combustion. Type Of Release: Thermal (Overload Protection) And Electromagnetic (Instantaneous Short Circuit Protection). Rated Operating Voltage (\(U_{E}\)): Not Less Than 400 V Ac (Frequency 50 Hz). Rated Insulation Voltage (\(U_{I}\)): Not Less Than 690 V. Rated Ultimate Breaking Capacity (\(I_{Cu}\)): Not Less Than 10 Ka (Kiloamperes) At A Voltage Of 400 V. Instantaneous Trip Setting Current (\(I_{I}\)): Not Less Than 800 A (This Is The Factory Setting Of Keaz For A Nominal Value Of 80A).2. Requirements For Design, Dimensions And Compatibility: Due To The Need To Install The Product In The Existing Limited Space Of The Distribution Cabinet, The Overall Dimensions Of The Supplied Device Must Not Exceed The Following Values: Width - No More Than 115 Mm, Height - No More Than 175 Mm, Depth - No More Than 135 Mm (Exact Physical Dimensions Of The Va57f35 Series Case). Installation/Installation Method: Stationary, On The Mounting Panel. Direction Of Connection Of External Conductors: Front.3. Quality, Certification And Completeness: The Product Must Be New, Not Used, Not Refurbished, Year Of Manufacture - No Earlier Than 2025–2026. The Product Body Must Be Intact, Without Cracks, Chips Or Traces Of Installation. The Delivery Package For Each Device Must Include: Interpolar Dielectric Partitions (At Least 2 Pcs.), A Set Of Mounting Screws, The Original Product Passport With A Mark From The Manufacturer’S Quality Control Department And An Instruction Manual. The Supplier Must Provide A Valid Certificate Of Conformity Or A Declaration Of Compliance With The Requirements Of The Technical Regulations Of The Customs Union (Eaeu): Tr Cu 004/2011 On The Safety Of Low-Voltage Equipment. The Warranty Period For The Supplied Goods Must Be At Least 12 Months From The Date Of Signing The Acceptance Certificate On The Government Procurement Portal., Power Contactor Cjx2-2510
Key Value
Tender Value
365,490 - KZT
Tender Documents
Global Tender Document
2dfc93b9-0308-4fdc-af1f-bc1babdf5ae7.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you