GTR 117391823

Tenders Are Invited For Procurement Of Medical Products.

ICB — International Competitive Bid Closes Sep 07, 2026 Central Asia
Tender Information
GTR Reference
117391823
Tendering Authority
Subscribe to view
Tender No
17533997
Financer Name
Self-Funded
Work Title
Tenders Are Invited For Procurement Of Medical Products.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
07-09-2026
Work Detail
Pistol Scalpel Sg35 For Laparoscopy, Vessels With A Diameter Of At Least 5 Mm. The Ultrasonic Coagulation Scalpel With An Ergonomic Pistol Grip Is Designed For A Wide Range Of Uses In The Surgical Field, Including Use During Open Or Laparoscopic Operations For Cutting And Dissecting Soft Tissue, Subject To The Requirement Of Bleeding Control And Minimal Thermal Exposure, With Manual And Pedal Activation. Used For Simultaneous Dissection And Coagulation Of Tissues And Vessels With A Diameter Of Up To 5 Mm. In Addition To The Main Functions Of Cutting And Coagulation, They Are Intended As A Tissue Clamp. The Vibration Frequency Of The Titanium Scalpel Blade In The Longitudinal Direction Is 55.6 Khz. Possibility Of Activating The Scalpel Using The Power Buttons In The Minimum And Maximum Power Modes Located On The Front Surface Of The Handle Body For Quick Access, Or Using The Control Pedals. The Handle Body Has A Built-In Mechanism For Tactile And Sound Indication Of Complete Closing Of The Jaws. The Presence Of A Feedback System With The Generator And Temperature Control Of The Active Blade Of The Nozzle, Using The Y16e Generator, To Increase The Efficiency And Speed Of The Tool, As Well As Reduce The Level Of Lateral Tissue Damage. The Presence Of An Additional Sound Signal Notifying The Beginning Of An Increase In The Temperature Of The Active Blade, For More Advanced Control Of The Quality Of Hemostasis. The Length Of The Barrel Is 35 Cm From The End Of The Active Branch To The Rotation And Rotation Handle. Barrel Diameter 5 Mm. Rotation Of The Barrel 360 Degrees Using A Rotation Handle Located At The Junction Of The Barrel And The Scalpel Handle Increases Access To The Operated Tissue. Availability Of A Threaded Connector For Connection With A Laparosonic Handle. Pistol Grip For Bringing The Jaws Together., Xenon Lamp 175 Bt (Pe175bfa) For Medical Xenon Illuminators Xenon Karl Storz. Lighting Intensity ~ From 1700 To 2200. Rated Power - 175 W. Rated Current (Constant) ~ 13-14 A. Operating Voltage 12-16 V. Temperature (Maximum) - 150°C, Recommended Ignition Voltage 23 Kv. -Uv Output, <390 Nm (W) 1.2. Guaranteed Operating Life: 500 Hours., Handle Hp401. A Laparoscopic Handpiece With Piezoceramic Elements Is Designed To Convert Electrical Pulses Of An Ultrasonic Surgical Generator Into High-Frequency Mechanical Vibrations With A Frequency Of 55.6 Khz And Transmit Them To The Blades Of Ultrasonic Scalpel Attachment Instruments, Which, Under Such Influence, Oscillate In The Longitudinal Direction. It Consists Of The Handle Itself With A Threaded Rod For Connection To Tool Attachments And A Flexible Insulating Wire With A Rubberized Plug For Connection To The Connector On The Front Panel Of The Generator. Color Mark On The Plug In The Form Of Arrows, For Quick Correct Orientation In The Connector When Connecting The Handle To The Generator. Availability Of A Built-In Counter For The Number Of Activations, Numbering 100 Activations. The Ability To Activate The Attachment Attached To The Handle Using A Manual Trigger On The Attachment Or A Removable Adapter To The Handle For Manual Activation Of Attachments, With Bilaterally Duplicated Buttons For Activating The Minimum And Maximum Power Modes, As Well As Using A Foot Pedal Drive. The Presence Of A Function For Testing The Condition Of The Handle With An Error Code Displayed On The Generator Display And A Specific Sound Indication In The Event Of A Malfunction Of The Handle Or Incorrect Connection Of The Handle To The Device Or Tool Attachment. Can Be Used With Open And Endoscopic Laparoscopic Surgery Attachments., Scalpel Scissors Ss9 For Laparotomy. The Scissor-Type Coagulation Ultrasonic Scalpel With An Ergonomic Handle Is Designed For A Wide Range Of Surgical Uses, Including Use During Open Surgery For Cutting And Dissecting Soft Tissue, Subject To The Requirement Of Bleeding Control And Minimal Thermal Impact, With Manual And Pedal Activation. Scissors With A Plastic Body, Two Scissor-Shaped Handles - Active And Fixed, Used For Simultaneous Dissection And Coagulation Of Tissues And Vessels With A Diameter Of Up To 5 Mm. In Addition To The Main Functions Of Cutting And Coagulation, They Are Intended As A Tissue Clamp. The Vibration Frequency Of The Titanium Scalpel Blade In The Longitudinal Direction Is 55.6 Khz. Possibility Of Activating The Scalpel Using The Power Buttons In The Minimum And Maximum Power Modes Located On The Front Surface Of The Handle Body For Quick Access, Or Using The Control Pedals. The Handle Body Has A Built-In Mechanism For Tactile And Sound Indication Of Complete Closing Of The Jaws.
Key Value
Tender Value
10,162,500 - KZT
Tender Documents
Global Tender Document
fc905419-2deb-4a46-a27d-9e8d9ea0490b.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders