GTR 116131223

Request For Quotation Purchasing Medical Products Through Subcontracting And Paid Services

ICB — International Competitive Bid Central Asia
Tender Information
GTR Reference
116131223
Tendering Authority
Subscribe to view
Tender No
17374971
Financer Name
Self-Funded
Work Title
Request For Quotation Purchasing Medical Products Through Subcontracting And Paid Services
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
28-07-2026
Work Detail
Zotarolimus Eluting Coronary Stent System The Stent Is Made Of A Composite Material (Cobalt And Platinum-Iridium Alloy). A Coronary Stent Consists Of A Single Wire Bent Into A Continuous Sinusoidal Curve, The Adjacent Rows Of Which Are Laser-Fused. The Delivery System Consists Of A Balloon-Expandable Intracoronary Stent Pre-Installed On A System With A Catheter Working Length Of 140 Cm. The Delivery System Is Compatible With Guidewires With A Maximum Outer Diameter Of 0.36 Mm (0.014 Inch) And With Guiding Catheters With A Minimum Inner Diameter Of 1.42 Mm (5 French / 0.056 Inch). The Stent Consists Of A Bare Metal Stent With A Primer Layer And A Coating Consisting Of A Mixture Of The Drug Zotarolimus And A Polymer System. Dimensions: Stent Length (Mm) 8, 12, 15, 18, 22, 26, 30, 34, 38; Stent Diameter (Mm) 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00, 4.50, 5.00., Diagnostic Conductor Conductor Material: Highly Elastic Nitinol-Based Alloy, Polyurethane And Tungsten Sheath, Polyurethane Coated Diagnostic Conductor Conductor Material: Highly Elastic Nitinol-Based Alloy, Polyurethane And Tungsten Sheath, Coated With Polyurethane. Availability Of A Choice Of Diameters: 0.018; 0.025; 0.032; 0.035; 0.038. Availability Of Choice Of Conductor Lengths: 50; 80; 120; 150; 180 Cm. Availability Of Choice Of Conductor Shape: Straight; Straight Rigid; Curved; 45º Bend; 45º Rigid Bend. Length Of The Flexible Distal Part: 10; 30; 50; 80 Mm. Presence Of A Polymer Hydrophilic Stable Coating M-Coat Along The Entire Length Conductor., Balloon Catheters For Transluminal Angioplasty Of Coronary Arteries. Diameter (Mm): 1.0; 1.25; 1.5 - 1 Radiopaque Mark;2.0; 2.25; 2.5; 2.75; 3.0; 3.25; 3.5; 3.75; 4.0 - 2 Radiopaque Marks. Length 5; 10; 15; 20; 30; 40 Mm. Balloon Material Nylon 12. Hydrophilic Coating Of The Balloon Catheter M-Coat. Features A Red Flexible Catheter Tip For Better Visibility. Stainless Steel Tapered Guidewire Core For Optimal Pushing Ability To Maximize Transmission Force. The Balloon Inlet Profile Is 0.41 Mm For Balloon Catheters With A Diameter Of 1.0 To 1.5 Mm And 0.43 Mm For Balloon Catheters With A Diameter Of 2.0 To 4.0 Mm. The Working Profile Of The Balloon Is 0.58 Mm For Balloon Catheters With A Diameter Of 1.0 Mm, 0.62 Mm For Balloon Catheters With A Diameter Of 1.25 Mm, And 0.73 Mm For Balloon Catheters With A Diameter Of 2.0 To 4.0 Mm. The Working Length Of The Catheter Is 145 Cm. The Nominal Pressure Is 6 Atm. Burst Pressure Is 14 Atm., For Balloon Catheters With A Diameter Of 1.0-3.0 Mm, And 12 Atm., For Boats With A Diameter Of 3.25-4.0 Mm. Material Of Radiopaque Balloon Label: Platinum - Iridium. Thin And Short Recessed Radiopaque Markers With A Length Of 0.8 Mm And A Thickness Of 25 Microns. The Presence Of Depth Markers At A Distance Of 90 Cm And 100 Cm From The Distal Tip Of The Catheter. Proximal Shaft Diameter - 1.9 Fr (0.64 Mm), Middle Shaft Diameter 2.5 Fr (0.84 Mm), Distal Shaft Diameter - 2.4 Fr (0.79 Mm) - 2.7 Fr (0.89 Mm) For Balloon Catheters With A Diameter Of 1.0 To 1.5 Mm And 2.6 Fr (0.87 Mm) For Balloon Catheters Diameter From 2.0 To 4.0 Mm. Compatible With 4Fr (0.050 Inch / 1.27 Mm) Guiding Catheter. Compatible With 0.014 Inch (0.36 Mm) Conductor. Balloon Design – Three-Lobe For Balloon Catheters With A Diameter From 2.25 To 4.0 Mm, Two-Lobe For Balloon Catheters With A Diameter From 1.0 To 2.0 Mm., Film For Dryview Dve Printers 35X43cm (125 L/Pack) Infrared Laser Film Dry View Dvb Format 35X43cm With A Resolution Of 325 Dpi Packaging 125L. Shelf Life Of Exposed Films For Over 100 Years For Dryview 5700 Laser Printer Used For Recording Images On Laser Printers Of A Series Of 35X43 Cm Films. Film Type: Photothermographic Film. Application: Designed For Printing Images Obtained From Digital Diagnostic Devices Such As X-Ray Machines And Other Medical Devices. Compliance: The Film Is Compatible With Digital Imaging Systems And Laser Printers, Providing High Quality And Crisp Images. Image Quality: Provides Accurate Detail, Contrast And Brightness, Which Is Important For Medical Diagnostics. Stability: High Image Stability And Durability, Which Is Important For Storing Medical Data, Indicator Set 1 Pc. - An Inflator Syringe With A Pressure Of No More Than 30 Atm, Similar To A Pressure Gauge With An Additional Line From 15 To 32 Cm (At The Customer’S Request) With A High-Pressure Multi-Way Valve. Convenient Opaque Polycarbonate Plunger, The Syringe Itself Is From 20 Ml To 30 Ml (According To The Customer’S Request) With A Division Price Of 2 Ml, A Dial At An Angle Of 45% For Maximum Accessibility To The Eye, With A Bright White Dial And Black Text For Clear Visualization. The Pressure Gauge Has Three Types Of Handles (According To The Customers Request): Barrel-Shaped, T-Shaped, And Round, All Types Have An Ergonomic Grip And Slots, For Working In Wet Environments, Reducing The Risk Of Slipping At High Pressures. The Coverage Of The Manometer Syringe Bulb Also Has 2 Types Of Handles For Support During Inflation And Deflation, On The Sides And Pistol Type (At The Customer’S Request) As Well As 3 Types Of Trigger Mechanism, Horizontal For Release With The Thumb And A Handle For Soft Release Using The Entire Palm; 1 Piece - Y-Shaped Connector With A Homeostatic Valve Of The “Click” Type From 7.5 To 9 Fr (At The Customer’S Request) Also Has 2 Silicone Membranes To Reduce Blood Loss During The Procedure Using The Intersection Technology; 1 Piece - Conductor Rotation Device. The Device Is Made Of Abc Plastic, The Body Is Covered With Diamond-Shaped Dots To Provide Better Grip When Working With Gloves. The Internal Metal Part Is A Dynamic Locking Mechanism That Allows The Conductor To Be Controlled And Manipulated Freely. Conductor Diameter 0.014-0.025; 1 Piece - Tool For Inserting The Conductor (Blunt Needle). The Tool Is Made Of Stainless Steel With A Length Of At Least 95 Mm, Has A Hub Made Of Medical Grade Polycarbonate, Id 0.022″ And Od G21; 1 Piece - Three-Way High-Pressure Valve To Control Contrast Medium Injections During Angiography Procedures With A Maximum Pressure Of Up To 600 Psi (41.3 Bar)., Angiography Procedural Kit, Coronary Controlled Conductor For Acute Occlusions Universal Coronary Conductors For Acute Occlusions Diameter: No More Than 0.014 (0.3556 Mm) Availability Of Lengths, Cm: 180-190 Cm Core Material: Stainless Steel, Core Type: Manufacturing Technology Composite Core Presence Single-Component Made Of Steel And Redundant, Running Parallel To Twisted Microcore Made Of Steel Wires. Rotation Transmission Presence 1:1 Reinforcement Required To Bend The Distal Part Of The Conductor 0.5. 0.7 G. Distal Radiopaque Spiral, Length: 3 Cm. Proximal Spiral Made Of Stainless Steel, Length: 15-25 Cm. Coating Of The Proximal Spiral: Ptfe. Presence Of A Backup (Internal) Core Braid. Possibility Of Extension Up To: No Less Than 300 Cm Options For Covering The Distal Part: Hydrophilic. Support Options: Standard And Additional Options For The Distal Tip: Straight And J Possibility Of Use Multiple Times During One Operation - To Provide Access To Vessels With Different Anatomical Characteristics, To Pass Through Affected Areas, Including Subtotal Stenoses, As Well As To Deliver Instruments - Coronary Balloons And Stents. Through Paid Services, Introducer Complete With Needle For Transradial Access Introducer For Transradial Access. Possibility Of Choosing Diameters 4, 5, 6, 7 Fr. Possibility Of Choosing The Length Of Introducers With A Length Of 7, 10 Cm. Possibility Of Choosing Introducers With An X-Ray Contrast Mark. Possibility To Select Color Coding For The Introducer Diameter. The Presence Of An Eyelet On The Introducer For Suturing To The Skin, Which Ensures Convenient Fixation Of The Introducer. Possibility Of Choosing A Two-Layer Wall, With An Outer Layer Of Etfe. Possibility Of Choosing A Dilator And Hemostatic Valve In The Kit. The Presence Of A Protective Mechanism On The Dilator That Prevents Spontaneous Opening. Possibility Of Choosing Introducers With Hydrophilic Coating. Availability Of Introducers With A Needle Included. Availability Of Choice Of An Introducer Kit With A Metal Needle Or A Needle-Catheter. Possibility Of Choosing Pediatric Kits. Dilator Length (Mm): 125; 155. Availability Of Choice Of Diameter Of A Straight, Steel Mini Conductor: 0.018, 0.021,0.025. The Length Of A Straight, Steel Mini Conductor Is 45 Cm. Needle 20Gx 35Mm (For A Mini Conductor 0.025), Needle 21Gx 35Mm (For A Mini Conductor 0.018), Needle 22Gx 35Mm (For A Mini Conductor Conductor 0.018)., Medical Diagnostic Latex Gloves, Non-Sterile, Smooth And Textured, Powdered, Sizes: S, M, L On Request Composition And Description Of The Product: The Gloves Are Made Of High-Quality Natural Rubber Latex. Key Components Of Latex Compounds: Natural Rubber Latex, Zdbc (Zinc Dibutyl Dithiocarbamate), Zddp (Zinc Diethyl Dithiocarbamate), Zinc Oxide, Wingstay-L Antioxidant, Sulfur, Titanium Dioxide, Epl Antifoam, Surface Lubricant Applications: Used In Medicine To Protect The Hands Of Healthcare Workers And Prevent The Spread Of Infection Subcontract, Diagnostic Catheter. Catheter Material: Outer Layer - Nylon With Polyurethane, Middle Layer - Double Braided Stainless Steel Throughout The Entire Length Of The Catheter, Except For The Distal 2 Cm, Inner Layer - Nylon With Polyurethane. Available In 4, 5 And 6 Fr Outer Diameters. Availability Of Increased Internal Clearance 4Fr No Less Than 0.041/1.03 Mm, 5Fr No Less Than 0.047/1.20 Mm, 6Fr No Less Than 0.051/1.30 Mm. Compatible With 0.038/0.97 Mm Conductor. Maximum Pressure No More Than 1000 Psi /6.895 Kpa. Soft Polypropylene Catheter Tip Except Pigtail. Availability Of Choice Of Catheter Lengths: 65Cm, 80Cm, 90Cm, 100Cm, 110Cm. Availability Of A Choice Of Special Forms For The Right And Left Coronary Arteries, For Transradial Access., Guiding Catheter Purpose For Carrying Out Interventional Instruments. Shape And Length: Possibility Of Choosing Special Shapes For Access Through The Radial (Tiger) And Femoral Arteries (Extra Backup) With A Length Of 100 Cm, And 125 Cm For Catheters With The Multipurpose Shape. The Presence Of A Double Metal High-Strength, Flat Braid In The Body Of The Catheter, The Catheter Material Is Polyamide. Availability Of Outer Diameter 5, 6, 7, 8 Fr. The Presence Of Increased Internal Clearance 5Fr-0.058; 6Fr-0.071, 7Fr-0.082; 8Fr-0.091. Maximum Pressure 725 Psi. Availability Of Choice Of Catheters With Side Openings For Catheters With A Diameter Of 6, 7, 8Fr. Availability Of Internal Ptfe Coating. The Presence Of An External Hydrophilic Coating Along The Entire Length Of The Catheter, With The Exception Of The Distal 7 Cm And Proximal 25 Cm. The Presence Of A Soft Tip 2 Mm Long. Compatible With The Catheter For The Mother&Child Technique And The “Kissing” Balloon Technique.
Key Value
Tender Value
795,896 - KZT
Tender Documents
Global Tender Document
774ede8a-5bf9-4f0f-852c-c730e4cc94d9.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders