GTR 114858019
Request For Quotation 01. Power Electrical Equipment (Z.555) (Service 366)/
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
114858019
Tendering Authority
Subscribe to view
Tender No
17232228
Financer Name
Self-Funded
Work Title
Request For Quotation 01. Power Electrical Equipment (Z.555) (Service 366)/
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
29-06-2026
Closed
Work Detail
Iae. Tip Type Nshvi 2.5-08 2.5Mm2 With Insulated Flange. Insulation Material: Pvc. Installation Method: Crimping; Crimp Rated Voltage Not Less Than 400 V. Operating Temperature Range From -10 To +75 C. The Diameter Of The Mounting Hole Is At Least 2.3 Mm. Unit Of Measurement Packaging. The Protective Surface Coating Is Tinned. Material Copper. The Diameter Of The Hole For The Core Is At Least 4 Mm. The Range Of Cable Cross-Sections Is Not Less Than 2.5 Mm2. The Number Of Pieces Per Package Is At Least 100 Pieces. Gost 23981-80. Certificate., Iae. Tip Type Nshvi 4-09 For 4Mm2 Wire. Insulation Material: Pvc. Installation Method: Crimping; Crimp Rated Voltage Is Not Less Than 400 V. Operating Temperature Range Is From -10 To +75 C. The Diameter Of The Mounting Hole Is Not Less Than 2.8 Mm. Unit Of Measurement Packaging. The Protective Surface Coating Is Tinned. Material Copper. The Diameter Of The Hole For The Core Is At Least 4.5 Mm. The Range Of Cable Cross-Sections Is At Least 4 Mm2. The Number Of Pieces Per Package Is At Least 100 Pieces. Gost 23981-80. Certificate., Iae. Functional, Technical, Operational, Quality Characteristics: A Potential Equalization Box Is A Connecting Device For Grounding Wires From The Grounding Bus Of The Electrical Panel To Conductive Elements Accessible To Touch. Climatic Design No Less Than Uhl4. Square Shape. Length Not Less Than 85 Mm. Height Not Less Than 40 Mm. Width No More Than 85 Mm. Type Of Distribution Box. The Maximum Cross-Section Of The Connected Cable Is 35 Mm2. Availability Of Terminal Block. Protection Degree 44. Operating Temperature Range Not Less Than -25+60°C. The Number Of Inputs Is At Least 6. The Material Of The Product Is Polystyrene. Version With Terminals. Certificate., Iae. Z-Shaped Profile. Length Not Less Than 2,000 Mm. Width Not Less Than 25 Mm. Height No More Than 55 Mm. Material Thickness 2 Mm. Material Steel. Protective Surface Coating Is Hot Galvanized Using The Sendzimir Method Z-Profile. Weight Per Storage Unit Is Not Less Than 1.78 Kg/Piece. Gost 11474-76. Certificate., Iae. Heat Shrink. Thin-Walled Model Or Version. The Internal Diameter Before Heat Shrinking Is At Least 8Mm. The Internal Diameter After Heat Shrinking Is At Least 6Mm. Nominal Cross-Section No More Than 12 Mm2. The Shrinkage Coefficient Is No More Than 2 To 1. The Wall Thickness After Shrinkage Is No Less Than 0.55±0.1 Mm. Installation Temperature Is Not Less Than -10...50 °C Range. The Minimum Temperature For The Start Of Shrinkage Is At Least 70 °C. Minimum Temperature For Complete Shrinkage: No More Than 125 °C. The Material Is Polyethylene. Operating Voltage Not Less Than 660V. Elongation To Break No Less Than ≥ 200%. Weight No More Than 0.006 Kg. Gost 17675-87. Certificate., Iae. Functional, Technical, Operational, Quality Characteristics: Clamp Type: Plastic. Scope Of Application For Pipe Clamps, For Cables. The Material Of The Clamp Is Polyamide. Band Width 7.2 Mm. Strip Length Is At Least 400 Mm. The Number Of Pieces Per Package Is At Least 100 Pieces. Certificate., Iae. End Coupling For 5-Core Cable. End Coupling Type. Voltage Not Less Than 1 Kv. Cable Insulation Type: Plastic. The Number Of Cores Is At Least 5. The Cross-Section Of The Cable Cores Is At Least 10, 25, 35. The Installation Technology Is Heat-Shrinkable. Installation Type Indoor/Outdoor Cable Type Vvg, Avvb, Vvbshv, Apvvbbshv, Nayby, N(A)Yy, N2xy, Axmk, Amcmk, Mcmk. Armor, Cable Shield Steel Tape Armor. The Cutting Length Is At Least 95 Mm. Gost 34839-22. Certificate., Iae. Insulated Ring Tip Type Nki-2-6 1.5-2.5 Mm2. For M6 Bolt. Insulation Material: Pvc. Installation Method: Crimping; Crimp Rated Voltage No Less Than 400 V. Operating Temperature Range No Less Than -10 To +75 C. Mounting Hole Diameter No Less Than 6.4 Mm. Unit Of Measurement Packaging. The Protective Surface Coating Is Tinned. Material Copper. The Diameter Of The Hole For The Core Is At Least 2.3 Mm. The Range Of Cable Cross-Sections Is Not Less Than 1.5 Mm2. The Number Of Pieces Per Package Is At Least 100 Pieces. Gost 9581-80. Certificate., Iae. Heat Shrink. Thin-Walled Model Or Version. The Internal Diameter Before Heat Shrinking Is At Least 6Mm. The Internal Diameter After Heat Shrinking Is At Least 6Mm. Nominal Cross-Section Not More Than 9 Mm2. The Shrinkage Coefficient Is No More Than 2 To 1. The Wall Thickness After Shrinkage Is No Less Than 0.55±0.1 Mm. Installation Temperature Is Not Less Than -10...50 °C Range. The Minimum Temperature For The Start Of Shrinkage Is At Least 70 °C. Minimum Temperature For Complete Shrinkage: No More Than 125 °C. The Material Is Polyethylene. Operating Voltage Not Less Than 660V. Elongation To Break No Less Than ≥ 200%. Weight No More Than 0.006 Kg. Gost 17675-87. Certificate., Iae. Heat Shrink. Thin-Walled Model Or Version. The Internal Diameter Before Heat Shrinking Is At Least 5Mm. The Internal Diameter After Heat Shrinking Is At Least 2.5Mm. Nominal Cross-Section No More Than 4.5 Mm2. The Shrinkage Coefficient Is No More Than 2 To 1. The Wall Thickness After Shrinkage Is No Less Than 0.55±0.1 Mm. Installation Temperature Is Not Less Than -10...50 °C Range. The Minimum Temperature For The Start Of Shrinkage Is At Least 70 °C. Minimum Temperature For Complete Shrinkage: No More Than 125 °C. The Material Is Polyethylene. Operating Voltage Not Less Than 660V. Elongation To Break No Less Than ≥ 200%. Weight No More Than 0.006 Kg. Gost 17675-87 Certificate., Iae. Tip Type Nshvi 1.5-08 1.5Mm2 With Insulated Flange. Insulation Material: Pvc. Installation Method: Crimping; Crimp Rated Voltage Is Not Less Than 400 V. Operating Temperature Range Is From -10 To +75 C. The Diameter Of The Mounting Hole Is Not Less Than 1.7 Mm. Unit Of Measurement Packaging. The Protective Surface Coating Is Tinned. Material Copper. The Diameter Of The Hole For The Core Is At Least 3.5 Mm. The Range Of Cable Cross-Sections Is Not Less Than 1.5 Mm2. The Number Of Pieces Per Package Is At Least 100 Pieces. Gost 23981-80. Certificate., Iae. End Coupling For 5-Core Cable. End Coupling Type. Voltage Not Less Than 1 Kv. Cable Insulation Type: Plastic. The Number Of Cores Is At Least 5. The Cross-Section Of The Cable Cores Is At Least 70, 95, 120. The Installation Technology Is Heat-Shrinkable. Installation Type Indoor/Outdoor Cable Type Vvg, Avvb, Vvbshv, Apvvbbshv, Nayby, N(A)Yy, N2xy, Axmk, Amcmk, Mcmk. Armor, Cable Shield Without Armor. The Cutting Length Is At Least 215 Mm. Gost 34839-22. Certificate., Iae. Heat Shrink. Thin-Walled Model Or Version. The Internal Diameter Before Heat Shrinking Is At Least 6Mm. The Internal Diameter After Heat Shrinking Is At Least 3Mm. Nominal Cross-Section Not More Than 6 Mm2. The Shrinkage Coefficient Is No More Than 2 To 1. The Wall Thickness After Shrinkage Is No Less Than 0.55±0.1 Mm. Installation Temperature Is Not Less Than -10...50 °C Range. The Minimum Temperature For The Start Of Shrinkage Is At Least 70 °C. Minimum Temperature For Complete Shrinkage: No More Than 125 °C. The Material Is Polyethylene. Operating Voltage Not Less Than 660V. Elongation To Break No Less Than ≥ 200%. Weight No More Than 0.006 Kg. Gost 17675-87. Certificate.
Key Value
Tender Value
1,255,303 - KZT
Tender Documents
Global Tender Document
9ef3dc77-7450-4055-aea2-77f77c888862.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.