Multijet Velocimetric Hydrometer Q3 2, 5 R160 ½, Without Connections. As Per Characteristics Below: Nominal Diameter 15Mm (1/2), Maximum Flow (Q4): 3, 125 M³ / Hour, Nominal Flow (Q3): 2, 5 M³ / Hour, Transition Flow (Q2): 0, 025 M³ / Hour, Minimum Flow (Q1): 0, 01563 M³ / Hour, Ranger 160, Minimum Idm Of 93% (Nbr15538/14), Magnetic Transmission, Magnetic Shielding That Prevents The Action Of External Magnetic Fields (Class Ii), Dry Type Watchmaking (Ip68), Glass Or Polycarbonate Dome, Rigid Transparent Watchmaking, With 45º Reading, Rotating Watchmaking, With 360º Rotation, Reading With 4 (Four) Digits, Printing Of The Demsur Name On Watchmaking, Model Approval From Inmetro, Sealing System That Offers A Guarantee Against Fraud On The Internal Mechanism, Length 165 Mm Without Connections, Blue Epoxy Paint, Sealing Plug Made Of Brass. In Compliance With Abnt Standard Nbr 5426:1985, Nbr 8194:2015, Nbr 15538/14, Nbr 16043 And Inmetro Ordinance No. 155/2022, Multijet Velocimetric Hydrometer Q3 4 R80 ¾ Inch, Without Connections. According To The Characteristics Below: Nominal Diameter 20 Mm (¾), Maximum Flow (Q4): 5 M³ / Hour, Nominal Flow (Q3): 4 M³ / Hour, 080 M³ / Hour, 050 M³ / Hour, Ranger 80, Model Approval Along With The Inmetro Sealing System That Offers A Guarantee Against Fraud To The Internal Mechanism, Length 190 Mm Without Connections, Multijet Velocimetric Hydrometer Q3 10 R80 1 Inch, Without Connections. As Per Characteristics Below: Nominal Diameter 25Mm (1), Maximum Flow (Q4): 12, Nominal Flow (Q3): 10 M³ / Hour, 200 M³ / Hour, Magnetic Shielding That Prevents The Action Of External Magnetic Fields (Class I), Flat And Fixed Clockwork, Length 260 Mm Without Connections, Q3 Multijet Velocimetric Hydrometer 16 R80 1.½, Without Connections. According To The Characteristics Below: Nominal Diameter 40 Mm (1.½), Maximum Flow (Q4): 20 M³ / Hour, Nominal Flow (Q3): 16 M³ / Hour, 320 M³ / Hour, Length 300 Mm Without Connections, Unijet Velocimetric Hydrometer Q3 1 R80 ½, Maximum Flow (Q4): 1, 25 M³ / Hour, Nominal Flow (Q3): 1 M³ / Hour, 020 M³ / Hour, 0125 M³ / Hour, Minimum Idm 94% (Nbr15538/14), Magnetic Shielding That Prevents The Action Of External Magnetic Fields (Class Iii), With Front Chamfer, Blue Epoxy Painting. In Compliance With The Abnt Nbr 5426:1985 Standard, Woltmann Q3 25 R80 Hydrometer Of 2, With Connections, As Per Characteristics Below: Nominal Diameter 50 Mm (2), Maximum Flow (Q4): 31, Nominal Flow (Q3): 25 M³ / Hour, 500 M³ / Hour, 3125 M³ / Hour, With Counter-Flange Connections, Dry Type Watchmaking (Ip67), Sealing System That Offers A Guarantee Against Fraud To The Internal Mechanism Printing The Demsur Name On The Watchmaking, Length 200 Mm, Blue Epoxy Painting. In Compliance With The Abnt Nbr 5426:1985 Standard, 1/2 Inch Blind Tube For Cutting Off The Water Supply - In Red Color, It Is A Device To Be Coupled To One Of The Ends Of The Water Meter (Replacing The Existing Tube), With A Coupling And Socket For A Sealing Washer (Trim) On One Of The Ends And A Standard Thread. Pipe At The Other End. It Has A Closed Body At Both Ends And A Slot Of Approximately 10Mm X 16Mm In The Middle Of The Body, With Internal Shape Reinforcement To Prevent Fraud By Perforating The Tube. Injected Into Polypropylene, Virgin Raw Material, Resistant To Pressure Of 15 Kgf/Cm2, Is Re-Usable And Has A 3-Year Warranty., ¾ Inch Blind Tube For Cutting Off The Water Supply - In C