GTR 114511325
Bids Are Invited For Acquisitions Of Hospital Medical Equipment I (Emh I)
ICB — International Competitive Bid
Closed
South America
Tender Information
GTR Reference
114511325
Tendering Authority
Subscribe to view
Tender No
90166/2026/2026
Financer Name
Self-Funded
Work Title
Bids Are Invited For Acquisitions Of Hospital Medical Equipment I (Emh I)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
30-06-2026
Closed
Work Detail
Surgical C-Arm For Intraoperative Fluoroscopy. (Application: Intraoperative Use In Orthopedic And Traumatological Surgeries. 1. Rotating Anode To Withstand The Thermal Load Of Serial Procedures. Dual Focus With Maximum Ratings Of 0.6 Mm And 1.2 Mm. Electronic Overload Protection And Digital Thermal Load Indicator. Detection Area. Minimum 20 Cm X 20 Cm. Minimum Spatial Resolution Of 2.5 Lp/Mm. Scanning Depth Of At Least 12 Bits. Digital Zoom, Brightness/Contrast Adjustment And Noise Reduction. Basic Tools For Measuring Distance And Angles On The Screen. 5.Mechanical Structure (C-Arm): Motorized Vertical Elevation Movement. Braking System And Locks. Mechanics For All Movements (Orbital, Angular And Longitudinal). 6. Visualization Station And Connectivity: 02 (Two) 19 Monitors Or 1 Large 27 Monitor (Single Display) With Screen Splitting; Both Options With Full Hd (2Mp) Or Higher; Econectivity (Via Wi-Fi) Dicom 3.0 (Store E Print). Digital Fixed X-Ray Device. (Fixed Digital Less Than 45 Kw, Voltage Range With Lower/Upper Limits Of At Least 50 To 120 Kvp And Tube Current Greater Than Or Equal To 500 Ma. The System Must Have An Exposure Capacity Of At Least 100 Kv With A Minimum Of 500 Ma Per 0.1 S (Totaling A Minimum Load Of 50 Mas In A Single Pulse). Or Manual, Ensuring Precise Adjustment Of The Exposure Field According To The Size Of The Image Receiver Used. 2. Stating And Movement: The Stating Must Be Of The Floor-Wall Column Type Or Mounted On Rails On The Floor (Self-Supporting/Floor-Floor), With A Minimum Longitudinal Displacement Of 2.00 M And Vertical Displacement With A Minimum Travel Of 1.20 M, Allowing It The Center Of The X-Ray Beam Reaches A Minimum Height (Approximately) Of ≤ 40 Cm And A Maximum Height Of ≥ 170 Cm In Relation To The Floor, Guaranteeing Full Coverage Of The Table At A Distance.
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
7a4d7034-3b1b-426a-bb3d-6466abcaa43a.html