GTR 114374101
Request For Quotation 01. Power Electrical Equipment (Z.555) (Service 366)
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
114374101
Tendering Authority
Subscribe to view
Tender No
17171982
Financer Name
Self-Funded
Work Title
Request For Quotation 01. Power Electrical Equipment (Z.555) (Service 366)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
18-06-2026
Closed
Work Detail
Iae. End Coupling For 5-Core Cable. End Coupling Type. Voltage Not Less Than 1 Kv. Cable Insulation Type: Plastic. The Number Of Cores Is At Least 5. The Cross-Section Of The Cable Cores Is At Least 10, 25, 35. The Installation Technology Is Heat-Shrinkable. Installation Type Indoor/Outdoor Cable Type Vvg, Avvb, Vvbshv, Apvvbbshv, Nayby, N(A)Yy, N2xy, Axmk, Amcmk, Mcmk. Armor, Cable Shield Steel Tape Armor. The Cutting Length Is At Least 95 Mm. Gost 34839-22. Certificate., Iae. Single-Key Open Switch. Material Polycarbonate/Polyamide. Open Installation Method The Number Of Executive Keys Is No More Than 1. Rated Voltage Is Not Less Than 250 V. Rated Current Is Not Less Than 10. The Number Of Poles Is Not More Than 1. The Degree Of Protection Is Not Less Than Ip65. Open Type Of Installation. Height Not Less Than 73 Mm. Depth No More Than 54 Mm. The Wire Cross-Section Is At Least 2.5Mm^2. The Degree Of Protection Of The Shell Is At Least Ip65. Temperature Limits For Storage And Transportation Are From +5°C To +40°C. Type Of Terminals: Screw. Current Frequency 50 Hz. Width No More Than 63 Mm. Gost 19761-81. Certificate., Iae. Mineral Fiber Board With Fire Resistant Coating. Thickness Not Less Than 52Mm. Product Width Is At Least 500 Mm. Product Height Is At Least 1000 Mm. Rectangular Shape. Gost 9573-2012. Certificate., Iae. End Coupling For 5-Core Cable. End Coupling Type. Voltage Not Less Than 1 Kv. Cable Insulation Type: Plastic. The Number Of Cores Is At Least 5. The Cross-Section Of The Cable Cores Is At Least 70, 95, 120. The Installation Technology Is Heat-Shrinkable. Installation Type Indoor/Outdoor Cable Type Vvg, Avvb, Vvbshv, Apvvbbshv, Nayby, N(A)Yy, N2xy, Axmk, Amcmk, Mcmk. Armor, Cable Shield Without Armor. The Cutting Length Is At Least 215 Mm. Gost 34839-22. Certificate., Iae. The Sealant Is Fire-Resistant. Model/Version Fire-Resistant Putty. Volume Not Less Than 10 Kg. Delivery Set: Bucket Capacity No More Than 14000 Ml. Gost 13489-79. Certificate., Iae. Copper Cable Lug. Length At Least 70 Mm. Width Not Less Than 18 Mm. Product Material Is Copper. Installation Method: Crimping. The Number Of Holes For Fastening Is No More Than 1. The Diameter Of The Fastening Hole Is No More Than 12 Mm. The Cross-Section Of The Connected Wires Is At Least 150 Sq. Mm. The Minimum Operating Temperature Is No More Than -40 Degrees. The Maximum Operating Temperature Is Not Less Than 80 Degrees. Gost 7386-80. Certificate., Iae. Copper Cable Lug. Length At Least 70 Mm. Width No More Than 18 Mm. Product Material Is Copper. Installation Method: Crimping. The Number Of Holes For Fastening Is No More Than 1. The Diameter Of The Fastening Hole Is No More Than 8.5 Mm. The Cross-Section Of The Connected Wires Is At Least 25 Sq. Mm. The Minimum Operating Temperature Is No More Than -40 Degrees. The Maximum Operating Temperature Is Not Less Than 80 Degrees. Gost 7386-80. Certificate., Iae. Junction Box For Open Wiring. Depth Not Less Than 49 Mm And Not More Than 51 Mm. Length And Width Not Less Than 99 Mm And Not More Than 101 Mm. Operating Temperature Range From -25 To 40 °C. Width Not Less Than 100 Mm. Gost 31195.2.5-2012. Certificate., Iae. Functional, Technical, Operational, Quality Characteristics: A Potential Equalization Box Is A Connecting Device For Grounding Wires From The Grounding Bus Of The Electrical Panel To Conductive Elements Accessible To Touch. Climatic Design No Less Than Uhl4. Square Shape. Length Not Less Than 85 Mm. Height Not Less Than 40 Mm. Width No More Than 85 Mm. Type Of Distribution Box. The Maximum Cross-Section Of The Connected Cable Is 35 Mm2. Availability Of Terminal Block. Protection Degree 44. Operating Temperature Range Not Less Than -25+60°C. The Number Of Inputs Is At Least 6. The Material Of The Product Is Polystyrene. Version With Terminals. Certificate., Iae. 2-Gang Socket With Grounding For Open Installation. The Degree Of Protection Is At Least Ip54. Rated Current 16 A. Cover In Housing. The Number Of Posts Is At Least 2. With Curtains, Protection Against Touching. The Maximum Cross-Section Of The Incoming Cable Is No More Than 2.5Mm². Model Or Version With Grounding (Protective) Contact. Operating Temperature Range From -25 To 40 °C. The Width Of The Device Is At Least 127 Mm. Connection Type Or Method: Screw Terminal. Rated Operating Voltage 250 V. With Hinged Lid. Frequency 50 Hz. Method Or Type Of Fastening With Screws. Rated Voltage Not Less Than 250 V. Type Or Brand Of Thermoplastic Material. Device Depth 55 Mm. Rated Current 16A. The Height Of The Device Is At Least 92 Mm. Gost 7396.1-89. Certificate., Iae. Terminal For Connecting Wires And Cables. The Number Of Contacts Is At Least 3. The Minimum Cross-Section Is No More Than 0.5 Sq. Mm. The Maximum Cross-Section Is Not Less Than 6.0 Sq. Mm. Wire Material: Copper, Aluminum. Rated Voltage Not Less Than 450V. Rated Current Is Not Less Than 32A. Gost Iec 60947-7-1-2016. Certificate., Iae. Tip Type Nshvi 2.5-08 2.5Mm2 With Insulated Flange. Insulation Material: Pvc. Installation Method: Crimping; Crimp Rated Voltage Not Less Than 400 V. Operating Temperature Range From -10 To +75 C. The Diameter Of The Mounting Hole Is At Least 2.3 Mm. Unit Of Measurement Packaging. The Protective Surface Coating Is Tinned. Material Copper. The Diameter Of The Hole For The Core Is At Least 4 Mm. The Range Of Cable Cross-Sections Is Not Less Than 2.5 Mm2. The Number Of Pieces Per Package Is At Least 100 Pieces. Gost 23981-80. Certificate., Iae. Tip Type Nshvi 4-09 For 4Mm2 Wire. Insulation Material: Pvc. Installation Method: Crimping; Crimp Rated Voltage Is Not Less Than 400 V. Operating Temperature Range Is From -10 To +75 C. The Diameter Of The Mounting Hole Is Not Less Than 2.8 Mm. Unit Of Measurement Packaging. The Protective Surface Coating Is Tinned. Material Copper. The Diameter Of The Hole For The Core Is At Least 4.5 Mm. The Range Of Cable Cross-Sections Is At Least 4 Mm2. The Number Of Pieces Per Package Is At Least 100 Pieces. Gost 23981-80. Certificate., Iae. Tip Type Nshvi 1.5-08 1.5Mm2 With Insulated Flange. Insulation Material: Pvc. Installation Method: Crimping; Crimp Rated Voltage Is Not Less Than 400 V. Operating Temperature Range Is From -10 To +75 C. The Diameter Of The Mounting Hole Is Not Less Than 1.7 Mm. Unit Of Measurement Packaging. The Protective Surface Coating Is Tinned. Material Copper. The Diameter Of The Hole For The Core Is At Least 3.5 Mm. The Range Of Cable Cross-Sections Is Not Less Than 1.5 Mm2. The Number Of Pieces Per Package Is At Least 100 Pieces. Gost 23981-80. Certificate., Iae. Terminal For Connecting Wires And Cables. The Number Of Contacts Is At Least 2. The Minimum Cross-Section Is No More Than 0.5 Sq. Mm. The Maximum Cross-Section Is Not Less Than 6.0 Sq. Mm. Wire Material: Copper, Aluminum. Rated Voltage Not Less Than 450V. Rated Current Is Not Less Than 41A. Gost Iec 60947-7-1-2016 Certificate., Iae. Heat Shrink. Thin-Walled Model Or Version. The Internal Diameter Before Heat Shrinking Is At Least 5Mm. The Internal Diameter After Heat Shrinking Is At Least 2.5Mm. Nominal Cross-Section No More Than 4.5 Mm2. The Shrinkage Coefficient Is No More Than 2 To 1. The Wall Thickness After Shrinkage Is No Less Than 0.55±0.1 Mm. Installation Temperature Is Not Less Than -10...50 °C Range. The Minimum Temperature For The Start Of Shrinkage Is At Least 70 °C. Minimum Temperature For Complete Shrinkage: No More Than 125 °C. The Material Is Polyethylene. Operating Voltage Not Less Than 660V. Elongation To Break No Less Than ≥ 200%. Weight No More Than 0.006 Kg. Gost 17675-87 Certificate., Iae. Heat Shrink. Thin-Walled Model Or Version. The Internal Diameter Before Heat Shrinking Is At Least 6Mm. The Internal Diameter After Heat Shrinking Is At Least 3Mm. Nominal Cross-Section Not More Than 6 Mm2. The Shrinkage Coefficient Is No More Than 2 To 1. The Wall Thickness After Shrinkage Is No Less Than 0.55±0.1 Mm. Installation Temperature Is Not Less Than -10...50 °C Range. The Minimum Temperature For The Start Of Shrinkage Is At Least 70 °C. Minimum Temperature For Complete Shrinkage: No More Than 125 °C. The Material Is Polyethylene. Operating Voltage Not Less Than 660V. Elongation To Break No Less Than ≥ 200%. Weight No More Than 0.006 Kg. Gost 17675-87. Certificate., Iae. Functional, Technical, Operational, Quality Characteristics: Clamp Type: Plastic. Scope Of Application For Pipe Clamps, For Cables. The Material Of The Clamp Is Polyamide. Band Width 7.2 Mm. Strip Length Is At Least 400 Mm. The Number Of Pieces Per Package Is At Least 100 Pieces. Certificate., Iae. Heat Shrink. Thin-Walled Model Or Version. The Internal Diameter Before Heat Shrinking Is At Least 6Mm. The Internal Diameter After Heat Shrinking Is At Least 6Mm. Nominal Cross-Section Not More Than 9 Mm2. The Shrinkage Coefficient Is No More Than 2 To 1. The Wall Thickness After Shrinkage Is No Less Than 0.55±0.1 Mm. Installation Temperature Is Not Less Than -10...50 °C Range. The Minimum Temperature For The Start Of Shrinkage Is At Least 70 °C. Minimum Temperature For Complete Shrinkage: No More Than 125 °C. The Material Is Polyethylene. Operating Voltage Not Less Than 660V. Elongation To Break No Less Than ≥ 200%. Weight No More Than 0.006 Kg. Gost 17675-87. Certificate., Iae. Heat Shrink. Thin-Walled Model Or Version. The Internal Diameter Before Heat Shrinking Is At Least 8Mm. The Internal Diameter After Heat Shrinking Is At Least 6Mm. Nominal Cross-Section No More Than 12 Mm2. The Shrinkage Coefficient Is No More Than 2 To 1. The Wall Thickness After Shrinkage Is No Less Than 0.55±0.1 Mm. Installation Temperature Is Not Less Than -10...50 °C Range. The Minimum Temperature For The Start Of Shrinkage Is At Least 70 °C. Minimum Temperature For Complete Shrinkage: No More Than 125 °C. The Material Is Polyethylene. Operating Voltage Not Less Than 660V. Elongation To Break No Less Than ≥ 200%. Weight No More Than 0.006 Kg. Gost 17675-87. Certificate.
Key Value
Tender Value
4,044,223 - KZT
Tender Documents
Global Tender Document
4320db50-e70a-421e-bf9e-7e2606aedf18.html
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.