GTR 114020304
Request For Quotation Laboratory Biochemical Analyzer
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
114020304
Tendering Authority
Subscribe to view
Tender No
17114611
Financer Name
Self-Funded
Work Title
Request For Quotation Laboratory Biochemical Analyzer
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
08-06-2026
Closed
Work Detail
Halogen-Tungsten Lamp (12V, 20Wt) Halogen-Tungsten Lamp Included In The Mindray Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. Mindray, Bs-240 Pro Closed System. For Manual Work. For Paid Services., Antistreptolysin O (Aso) R1:1×23 Ml+R2:1×23 Ml+Calibrator:1×0.5 Ml. A Kit For Determining Antistreptolysin O Ii With A Calibrator In Blood Serum From The Mindray Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. R1:1×23 Ml+R2:1×23 Ml+Calibrator:1×0.5 Ml In Original Bottles. 132 Def. The Kit Must Be Marked With A Special Bar Code Compatible With The Closed System Reader. For Manual Work. For Paid Services., Diagnostic Reagent Kit For The Determination Of Creatinine (2×27 + 1×18) Two-Component Reagent Kit For The Determination Of Crea-J. The Volume Of The Working Solution Is At Least 210 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted To The Reagent Carousel Of The Analyzer. Containers Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer. For Manual Work. For Paid Services., Direct Bilirubin (4*35Ml+2*18Ml) Kit For Determining Direct Bilirubin In Blood Serum From The Mindray Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. R1-4X35ml, R2-2X18ml In Original Bottles. * Bil-D (Vox Method). 600 Def. The Kit Must Be Marked With A Special Bar Code Compatible With The Closed System Reader. For Manual Work. For Paid Services., Gamma-Glutamyltransferase (Ggt) R1:4×35 Ml+R2: 2×18 Ml R1:4×35 Ml+R2:2×18 Ml. For Manual Work. For Paid Services., Diagnostic Kit Of Reagents For Determining Total Bilirubin (4X35+2X18) Kit For Determining Total Bilirubin In Blood Serum From The Mindray Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. R1-4X35ml, R2-2X18ml In Original Bottles. *Bil-T (Vox Method). 600 Def. The Kit Must Be Marked With A Special Bar Code Compatible With The Closed System Reader. For Manual Work. For Paid Services., Rheumatoid Factor (Rf) R1:1×40 Ml+R2:1×11 Ml. Kit For Determining Rheumatoid Factor Ii With A Calibrator In Blood Serum From The Mindray Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. R1: 1×40 Ml+R2: 1×11 Ml In Original Bottles. 202 Def. The Kit Must Be Marked With A Special Bar Code Compatible With The Closed System Reader. For Manual Work. For Paid Services, C-Reactive Protein (Crp) 1*40Ml +1*10Ml, Kit For Determining C-Reactive Protein In Blood Serum From The Mindray Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. R1-4X40ml, R2-1X10ml In Original Bottles. *(Srb) (Nephelometry Method). 120 Def. The Kit Must Be Marked With A Special Bar Code Compatible With The Closed System Reader. For Manual Work. For Paid Services., Diagnostic Reagent Kit For Determining Total Cholesterol (4X40) One-Component Reagent Kit For Determining Chol/Tc. The Volume Of The Working Solution Is At Least 160 Ml. The Reagent Must Be Packaged In The Original R1 Disposable Container To Prevent Contamination And Does Not Require Transfer To An Additional Cartridge. The Containers Must Be Fully Adapted For The Analyzers Reagent Carousel And Equipped With A Special Barcode That Is Fully Compatible With The Analyzers Built-In Scanner. Carry Out Calibration And Quality Control Procedures Using Multisera Only. There Is No Need For Repeated Procedures For Programming The Method In The Analyzer’S Memory And Placing Containers In Strictly Defined Cells Of The Reagent Carousel. For Manual Work. For Paid Services., Diagnostic Reagent Kit For Determining Alkaline Phosphatase R1 4*35Ml +R2 2*18 Two-Component Reagent Kit For Determining Alp. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted To The Reagent Carousel Of The Analyzer. Containers Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer. For Manual Work. For Paid Services., Specific Calibrator Proteins, 5×1Ml (C3, C4, Crp, Iga, Igg, Igm, C Reactive Protein) Lyophilisate For Preparing 1 Ml Of Calibration Serum With A Known Content Of C3, C4, Crp, Iga, Igg, Igm, C Reactive Protein. The Kit Includes A Closed-Type Mindray Biochemical Analyzer Without Arbitrary Methods. 5 Bottles. The Packaging Must Be Marked With A Special Bar Code Compatible With The Reader For A Closed System. For Manual Work. For Paid Services., Calcium (Ca) (4*40Ml) Mindray. Kit For Determining Calcium In Blood Serum From The Mindray Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. .R-4X40ml, In Original Bottles. (Ca) (Colorimetric Method) 728 Def. The Kit Must Be Marked With A Special Bar Code Compatible With The Closed System Reader. For Manual Work. For Paid Services, Set Of Iron (Fe) (Colorimetric Analysis) R1:2*40 Ml+R2:1*16 Ml+Calibrator:1*1.5 Ml Set For Determining Iron In Blood Serum From The Mindray Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. R1:2×40 Ml+R2:1×16 Ml+Calibrator:1×1.5 Ml In Original Bottles. (Fe) (C And Q) 480 Def. The Kit Must Be Marked With A Special Bar Code Compatible With The Closed System Reader. For Manual Work. For Paid Services., Diagnostic Reagent Kit For The Determination Of Glucose (4X40 +2X20) Two-Component Reagent Kit For The Determination Of Glu-Godpap. The Volume Of The Working Solution Is At Least 200 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted To The Reagent Carousel Of The Analyzer. Containers Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer. For Manual Work. For Paid Services., Diagnostic Set Of Reagents For The Determination Of Uric Acid (4*40+2*20) Two-Component Set Of Reagents For The Determination Of Ua. The Volume Of The Working Solution Is At Least 200 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted To The Reagent Carousel Of The Analyzer. Containers Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer. For Manual Work. For Paid Services., Albumin (Alb) (4*40Ml). A Kit For Determining Albumin In Blood Serum From The Mindray Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. R1-4X40ml In Original Bottles. *(Alb) (Method With Bromocresol Green) 728 Def. The Kit Must Be Marked With A Special Bar Code Compatible With The Closed System Reader. For Manual Work. For Paid Services, Diagnostic Reagent Kit For Determining Total Protein (4X40) One-Component Reagent Kit For Determining Tp. The Volume Of The Working Solution Is At Least 160 Ml. The Reagent Must Be Packaged In The Original R1 Disposable Container To Prevent Contamination And Does Not Require Transfer To An Additional Cartridge. The Container Must Be Fully Adapted To The Reagent Carousel Of The Analyzer. The Container Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer. For Manual Work. For Paid Services., Lactate Dehydrogenase R1: 4X35 Ml + R2: 2X18 Ml. Kit For Determining Lactate Dehydrogenase In Blood Serum From The Mindray Closed-Type Biochemical Analyzer Kit Without Arbitrary Methods. R1-4X35ml, R2-2X18ml In Original Bottles. 500 Def. The Kit Must Be Marked With A Special Bar Code Compatible With The Closed System Reader. For Manual Work. For Paid Services, Diagnostic Reagent Kit For The Determination Of Alpha-Amylase Bs R1: 1X38 Ml + R2: 1X10 Ml – Mindray Bs-240 Pro Closed System. Two-Component Reagent Kit For Ams Determination. The Volume Of The Working Solution Is At Least 48 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted To The Reagent Carousel Of The Analyzer. Containers Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer. For Manual Work. For Paid Services., Diagnostic Set Of Reagents For The Determination Of Urea (4X35+2X18) Two-Component Set Of Reagents For The Determination Of Bun/Urea. The Volume Of The Working Solution Is At Least 176 Ml. Reagents Should Be Packaged In Single-Use Original Containers R1 And R2 To Prevent Contamination And Do Not Require Transfusion Into Additional Cartridges. The Containers Must Be Fully Adapted To The Reagent Carousel Of The Analyzer. Containers Must Be Equipped With A Special Barcode Compatible With The Built-In Scanner Of The Analyzer. For Manual Work. For Paid Services.
Key Value
Tender Value
3,845,255 - KZT
Tender Documents
Global Tender Document
cd343326-11a4-42c5-899a-16ee10ad7e29.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer