Request For Quotation Laboratory Hemostasis Analyzer

Tender Detail

114020252
17117224
Self-Funded
Request For Quotation Laboratory Hemostasis Analyzer
NCB
Central Asia
Commonwealth of Independent States, CIS
08-06-2026

Work Detail

Biophen™ Normal Control Plasma (Control Plasma 1) The Biophen™ Normal Control Plasma Kit Is A Kit Of Normal Citrated Human Plasma, Lyophilized, Intended For Quality Control Of Certain Coagulation Factor Assays. Composition: Normal Human Citrated Plasma, Lyophilized. Control Plasma Contains Stabilizing Agents. Packaging: 12 X 1Ml. Storage Conditions: Reagents Should Be Stored At 2–8°C In The Original Packaging Box. Use Before The Expiration Date Indicated On The Box. The Stability Of The Reagent After Dilution, Without Any Contamination Or Evaporation, When Stored Unopened, Is: • For At, Pc; Vii-X, Plasminogen, Fii, Fvii, Fix, Fx, Fxi, Fxii, Fxiii, Fibrinogen, Apcr (%Fvl), Lupus Anticoagulant, Pt/Inr/%, Aptt, Vwf:Ag, Α2-Ap And Thrombin Time: 24 Hours At 2–8 °C, 8 Hours At Room Temperature (18–25 °C), 2 Months At -20 °C Or Lower. • For Fviii:C, Fv And Ps: 8 Hours At 2-8°C, 4 Hours At Room Temperature (18-25°C), 2 Months At -20°C Or Below. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services., Biophen™ Plasma Calibrator The Biophen™ Plasma Calibrator Contains Lyophilized Normal Citrated Human Plasma. It Can Be Used As A Calibrator For The Analysis Of Certain Blood Clotting Factors. Composition: Normal Citrated Human Blood Plasma, Lyophilized. Packaging: 12X1ml. Storage Conditions: Reagents Should Be Stored At 2–8°C In The Original Packaging Box. Use Before The Expiration Date Indicated On The Box. The Stability Of The Reagent After Reconstitution, Without Any Contamination Or Evaporation, When Stored Unopened Is: For At, Pc; Fvii-X, Plasminogen, Fii, Fvii, Fix, Fx, Fxi, Fxii, Fxiii, Fibrinogen, Α2-Ap And Vwf: Ag: 24 Hours At 2-8°C, 8 Hours At Room Temperature (18-25°C), 2 Months At -20°C Or Below. For Fviii:C, Fv And Ps: 8 Hours At 2-8°C, 4 Hours At Room Temperature (18-25°C), 2 Months At -20°C Or Below. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services., Biophen™ Abnormal Control Plasma (Control Plasma 2). The Biophen™ Abnormal Control Plasma Kit Is A Citrated, Lyophilized Human Plasma Kit Designed For Quality Control Of Certain Coagulation Factor Assays. Ingredients: Abnormal Human Citrated Plasma, Lyophilized. Control Plasma Contains Stabilizing Agents. Packaging: 12 X 1Ml. Storage Conditions: Reagents Should Be Stored At 2–8°C In The Original Packaging Box. Use Before The Expiration Date Indicated On The Box. The Stability Of The Reagent After Dilution, Without Any Contamination Or Evaporation, When Stored Unopened, Is: • For At, Pc; Vii-X, Plasminogen, Fii, Fvii, Fix, Fx, Fxi, Fxii, Fxiii, Fibrinogen, Apcr (%Fvl), Lupus Anticoagulant, Pt/Inr/%, Aptt, Vwf:Ag, Α2-Ap And Thrombin Time: 24 Hours At 2–8 °C, 8 Hours At Room Temperature (18–25 °C), 2 Months At -20 °C Or Lower. • For Fviii:C, Fv And Ps: 8 Hours At 2-8°C, 4 Hours At Room Temperature (18-25°C), 2 Months At -20°C Or Below. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services, Wash Solution Ca Clean Ii 1 X 500Ml. Intended For Use As A Washing Reagent When Working On Clotting Factor Analyzers Composition: Hydrochloric Acid 0.16%, Nonionic Surfactant 0.50%. Stability After Opening (Closed Bottle): At Temperatures From 15 To 25°C - 2 Months. Packaging: 1X500 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services, Reaction Cells For Cs 2100. Cells For Carrying Out Analytical Reactions And Recording By Optical Methods In The Visible And Ultraviolet Parts Of The Spectrum. Plastic Container 0.6 Ml With A Fixing Ring, Height 30 Mm, Diameter 8 Mm, Ring Diameter - 10 Mm. Packaging 3X1000 Pcs. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services, Fibriphen™ Lrt (Fibrinogen Reagent) Reagent For The In Vitro Quantitative Determination Of Fibrinogen In Citrated Human Plasma By The Clauss Method Using A Manual Or Automatic Method. Reagent Composition: Liquid Reagent Containing Bovine Calcium Thrombin (Approximately 100 Nih/Ml), Bsa, Heparin Neutralizer And Preservatives. The Reagent Is Ready For Use. Packaging: 6 X 5 Ml. Storage Conditions: Reagents Should Be Stored At 2–8°C In The Original Packaging Box. Use Before The Expiration Date Indicated On The Box. The Stability Of The Reagent After Opening, Without Any Contamination Or Evaporation, And When Stored Unopened Is: 90 Days At A Temperature Of 2–8 °C. Confidence: Less Than 9% Bias For All Samples. Precision: Coefficient Of Variation (Cv) For All Samples Is Less Than 6% For Repeatability, Less Than 9% For Reproducibility, And Less Than 9% For Within-Laboratory Analysis. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services., Sap-400A Sample Plate (Sap 400A Sample Plate). A Plastic Plate With 50 Wells Is Used In Standard Mode, As Well As When Constructing A Calibration Curve And When Analyzing Coagulometer Tests With Multi-Step Dilution. Manufacturer: Japan (Sysmex Corp.); Type: Consumables; Declaration Of Conformity: Not Subject To Mandatory Certification; Hazard Class: Not Dangerous; Weight: 1 Kg; Storage Conditions: +15-25˚С; Transportation At: +15-25˚С; Suitable For Sysmex; Material: Polystyrene; Packaging Dimensions: 36.5X14.5X9cm; For Manual Work. For Paid Services, Mini Cup Sld (Sld-400A) (Sld Mini Cup) Cuvette For Controls And Calibrators With A Conical Bottom. Purpose: Cuvette (Adapter) To Reduce The Dead Volume Of Controls And Calibrators To 0.1 Ml. Material: Polystyrene. Conical Bottom. Bottle Volume - 1 Ml. Packaging 500 Pcs. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of Calibration On Standard Samples Approved By The Manufacturer, The Supplier Upon Delivery Performs A Spectral Kit Calibration. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services., Hemoclot™ Thrombin Time Lrt Reagent For The Quantitative Determination Of Thrombin Time In Citrated Human Plasma By Coagulation, Manual Or Automatic. Hemoclot™ Thrombin Time Lrt Liquid Reagents Are Ready To Use, Containing Bovine Thrombin And Calcium, Bsa, Preservatives And Stabilizers. The Bovine Thrombin Concentration (Approximately 1.0 Nih/Ml) May Vary By Lot And Is Adjusted For Each Lot To Ensure That The Thrombin Time Test Is Highly Sensitive To Low Concentrations Of Unfractionated Heparin (Ufh) And Low Molecular Weight Heparin (Lmwh). Packaging: 6 X 5 Ml. Storage Conditions: Reagents Should Be Stored At 2–8°C In The Original Packaging Box. Use Before The Expiration Date Indicated On The Box. The Stability Of The Reagent After Opening, Without Any Contamination Or Evaporation, When Stored Unopened Is: 4 Weeks At 2–8 °C, 7 Days At Room Temperature (18–25 °C). Do Not Freeze. No Interference With Molecules Was Observed Up To The Following Concentrations: Intralipids - 500 Mg/Dl, Hemoglobin - 1000 Mg/Dl, Bilirubin - 75 Mg/Dl, Apixaban/Rivaroxaban/Edoxaban - 500 Ng/Ml, D-Dimer - 400 Μg/Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services., Pt Calibrator Set A Set Of Five Certified Plasmas Is Designed To Construct A Calibration Curve For Determining Prothrombin Time In Human Plasma ((H)Pt-Phen™ And Pt-Phen™ Lrt). Release Form: Lyophilized. Packaging: 5 X 2 X 1 Ml. Composition: Cal1 - Lyophilized Human Plasma With A Pt% Value Greater Than 90%, Cal2 - Lyophilized Human Plasma With A Pt% Value Of Approximately 65%, Cal3 - Lyophilized Human Plasma With A Pt% Value Of Approximately 45%, Cal4 - Lyophilized Human Plasma With A Pt% Value Approximately 28%, Cal5 - Lyophilized Human Plasma With A Pt% Value Less Than 20%. Calibration Plasma Contains Stabilizing Agents. Storage Conditions: Reagents Should Be Stored At 2–8°C In The Original Packaging Box. Use Before The Expiration Date Indicated On The Box. The Stability Of The Reagent After Reconstitution, Without Any Contamination Or Vapors And When Stored Unopened, Is: 24 Hours At 2-8 °C. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services., Calcium Chloride 0.025M (M/40) Calcium Chloride Solution For Coagulation Studies Using An Automated Method. This In Vitro Diagnostic Product Is Intended For Professional Laboratory Use. Composition: Solution Of Calcium Chloride With A Concentration Of Approximately 0.025 M, Ready For Use. Contains Preservatives And Stabilizers. Packaging: 12 X 15 Ml. Stability And Storage: Unopened Reagents Should Be Stored At 2–8°C In The Original Container. In Such Conditions They Are Suitable Until The Expiration Date Indicated On The Kit. Reagent Stability After Opening: 60 Days At 2–8°C. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services., Cephen 5 Reagent For The In Vitro Quantitative Determination Of Activated Partial Thromboplastin Time (Aptt) In Citrated Human Plasma By Coagulation, Manual Or Automatic. Method: Determination Of Plasma Recalcification Time In The Presence Of A Standardized Reagent Aptt (Phospholipids And Activator) On Citrated Human Plasma, As A General Screening Test For Assessing The Activity Of Coagulation Factors (Ii, V, X, Viii:C, Ix, Xi, Xii) And Fibrinogen. The Reagent Is Moderately Sensitive To The Lupus Anticoagulant (La). The Reagent Is Ready For Use. Reagent Composition: Aptt Activator (Micronized Silicate) Approximately 1 G/L, Plant Soy Phospholipids, Liquid Form. Contains Preservatives And Stabilizers. Packaging: 8 X 5 Ml. Storage Conditions: Reagents Should Be Stored At 2–8°C In The Original Packaging Box. Use Before The Expiration Date Indicated On The Box. The Stability Of The Reagent After Opening, Without Any Contamination Or Evaporation And When Stored Unopened, Is: 90 Days At A Temperature Of 2-8 °C. Confidence: Less Than 13% Bias For All Samples. Precision: Coefficient Of Variation (Cv) For All Samples Is Less Than 2% For Repeatability, Less Than 5% For Reproducibility, And Less Than 7% For Within-Laboratory Analysis. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services., Ourena Buffer Veronal 10 X 15 Ml. Dilution Buffer For Coagulation Samples. The Content Of Sodium Barbital Is Not Less Than 0.028 Mol/L. Reagent Bottles: Barcoded. Release Form: Liquid, Ready For Use. Stability After Opening At Temperatures From +2 To +8°C For At Least 8 Weeks. Packing: At Least 10 Bottles Of 15 Ml. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services., Conical Cups. Conical Sample Cup, Volume 4 Ml. Packaging 100 Pcs/Pack. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services., Pt-Phen™ Lrt (Pt Reagent) Reagent For The Quantitative Determination Of Prothrombin Time (Pt) In Human Citrated Plasma By Coagulation Method On Automatic Analyzers. Designed To Screen For Coagulation Disorders (Extrinsic Pathway) And Monitor Vitamin K Antagonist (Vka) Treatment. The Reagent Is Ready For Use. Ingredients: Pt-Phen Lrt Liquid Reagent Containing Approximately 200 Ng/Ml Recombinant Human Tissue Factor (Rec(H)Tf), Bsa, Specific Heparin Neutralizing Agent, Preservatives And Stabilizers. The Isi Value For The Reagent Lot Used Is Listed In The Information Sheet Supplied With The Kit. Packaging: 12 X 5 Ml. Storage Conditions: Reagents Should Be Stored At 2–8°C In The Original Packaging Box. Use Before The Expiration Date Indicated On The Box. The Stability Of The Reagent After Opening, Without Any Contamination Or Evaporation, When Stored Unopened Is: 1 Month At A Temperature Of 2–8 °C. Interference Is Not Expected For Heparins Up To 2 Iu/Ml (Ufh/Lmwh), The Reagent Contains A Substance That Neutralizes Heparin. To Determine Compatibility With The Software Of Medical Equipment Available To The Customer, And Subsequent Validation Of The Calibration On Standard Samples Approved By The Manufacturer, The Supplier Performs Spectral Calibration Of The Kit Upon Delivery. The Supplied Kit Must Be Compatible With The Version Of The Installed Software. For Manual Work. For Paid Services.

Key Value

Tender Value
37,77,286 - KZT

Attachment

FileName File Description
Global Tender Document 29ed1828-9051-453a-bb53-902cf07018e1.html
Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail

WhatsApp