Reagent For Determination Of Ferritin. The Kit Is Intended For In Vitro Chemiluminescent Immunoassay For The Quantitative Determination Of Ferritin In Human Serum Using An Automatic Chemiluminescent Immunoanalyzer Of The Maglumi Series. The Kit Contains: Magnetic Microparticles Coated With Monoclonal Antibodies Against Ferritin, Containing Bsa, Nan3 (<0.1%). 2.5 Ml, Low Concentration Ferritin Antigen Calibrator - 2.5 Ml, High Ferritin Antigen Calibrator - 2.5 Ml, Buffer - 12.5 Ml, Monoclonal Anti-Ferritin Antibodies, Abei Labeled, Containing Bsa, Nan3 (<0.1%) - 22.5 Ml, 0.9% Nacl Diluent - 25.0 Ml, Internal Control Quality, Containing Ferritin Antigen, -2.0 Ml. All Reagents Are Supplied Ready For Use. Set For 100 Tests. Storage Temperature 2-8°C. For Manual Work. For Paid Services, Reagent For The Determination Of Thyroid-Stimulating Hormone (Tsh) Maglumi Tsh (Clia) - Quantitative Test For The Determination Of Thyroid-Stimulating Hormone (Tsh Or Thyrotropin) For The Automatic Chemiluminescent Immunoanalyzer Maglumi (800, 2000, 4000+, X8, X3) Defined Parameters: Maglumi Tsh (Clia) Test Principle: Quantitative For The Determination Of Thyroid Stimulating Hormone (Tsh Or Thyrotropin) In Human Serum By In Vitro Analysis. Test Method: Chemiluminescent Immunoassay Number Of Tests In The Set: 100 Pieces. Complete Set: Quality Control And Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Reagent Information And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks. Storage Conditions And Shelf Life 1. When Sealed: Store At 2 - 8 °C Until Expiration Date. 2. Shelf Life 12 Months. 3. Open At 2-8°C: Stable For At Least 4 Weeks. 4. When Installed In The Analyzer: Stability Is Maintained For At Least 4 Weeks. 5 To Ensure Maximum Quality, It Is Recommended That Opened Kits Be Refrigerated After Assays Performed During The Workday. After The Expiration Date For Open Kits Or Kits Installed In The Analyzer, You Can Continue To Use The Reagent Kit Provided That The Results Obtained Using Control Samples Are Within The Expected Ranges. 6.Store In An Upright Position To Facilitate Proper Re-Suspension Of Magnetic Microparticles. 7. Store In Places Protected From Sunlight. For Manual Work. For Paid Services., A 5 Liter Plastic Canister Contains A Ready-To-Use Reagent, Which Is Used To Dilute Samples Before Urine Analysis And Prepare A Cell Suspension. The Product Is A Clear Liquid Without Sediment, Particles Or Flakes. Main Components: Polyoxyethylene Lauryl Ether (0.1 G/L-1.0 G/L), Sodium Methyl Parahydroxybenzoate (0.01 G/L-1.0 G/L), Nacl (4.5 G/L-11.5 G/L). Manufacturer: Shenzhen Mindray Bio-Medical Electronics Co., Ltd. Storage Conditions: From 2 ºc To 40 ºc At A Relative Humidity Of No More Than 93%. Shelf Life 2 Years. For Paid Services. For Manual Work, A Set Of Starting Reagents Designed To Generate A Chemiluminometric Light Signal Necessary For Analysis Using An Automatic Chemiluminescent Immunological Analyzer (Clia) Maglumi. Storage Conditions And Stability Starting Reagents Should Be Stored In Tightly Sealed Original Bottles. Store Reagents At 15 To 30 °C Until The Expiration Date Stated On The Label (12 Months From The Date Production). Stability When Stored In The Apparatus: 4 Weeks. Reagents Must Be Protected From Direct Sunlight. For Paid Services. For Manual Work, Maglumi Flushing Concentrate Is A Solution That Is Used By Dilution To Obtain A Flushing Liquid, Designed To Wash Out Magnetic Microparticles During Analysis Using An Automatic Chemiluminescent Immunological Analyzer Maglumi Series (Including Models Maglumi 600, Maglumi 800, Maglumi 1000, Maglumi 1000 Plus, Maglumi 2000, Maglumi 2000 Plus, Maglumi 4000 And Maglumi 4000 Plus). Storage And Shelf Life Wash Concentrate Should Be Stored At 15-30°C Until The Expiration Date Stated On The Label. (12 Months From Production Date). Shelf Life Of The Finished Washing Liquid: 4 Weeks At A Temperature Of 15–30 °C. Do Not Expose To Direct Sunlight. For Paid Services. For Manual Work, Reagent For The Determination Of Cortisol. Maglumi Cortisol (Clia) - Quantitative Test For The Determination Of Cortisol (Cortisol) For The Automatic Chemiluminescent Immunoanalyzer Maglumi (800, 2000, 4000+, X8, X3) Determined Parameters: Maglumi Cortisol (Clia) Test Principle: Quantitative For The Determination Of Cortisol (Cortisol) In Human Serum Or Urine In Vitro Analysis. Test Method: Chemiluminescent Immunoassay Number Of Tests In The Set: 100 Pieces. Contents Set: Quality Control, Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Reagent Information And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks. Storage Conditions And Shelf Life 1. When Sealed: Store At 2 - 8 °C Until Expiration Date. 2. Shelf Life 12 Months. 3. Open At 2-8°C: Stable For At Least 4 Weeks. 4. When Installed In The Analyzer: Stability Is Maintained For At Least 4 Weeks. 5 To Ensure Maximum Quality, It Is Recommended That Opened Kits Be Refrigerated After Assays Performed During The Workday. After The Expiration Date For Open Kits Or Kits Installed In The Analyzer, You Can Continue To Use The Reagent Kit Provided That The Results Obtained Using Control Samples Are Within The Expected Ranges. 6.Store In An Upright Position To Facilitate Proper Re-Suspension Of Magnetic Microparticles. 7. Store In Places Protected From Sunlight. For Manual Work. For Paid Services., Reagent For The Determination Of Luteinizing Hormone (Lh) Maglumi Lh (Clia) - Quantitative Test For The Determination Of Luteinizing Hormone (Lh) For The Automatic Chemiluminescent Immunoanalyzer Maglumi (800, 2000, 4000 Plus, X8, X3) Defined Parameters: Maglumi Lh(Clia) Test Principle: Quantitative For The Determination Of Luteinizing Hormone (Lh, Also Called Lutropin Or Lutrophin) In Human Serum By In Vitro Analysis. Test Method: Chemiluminescent Immunoassay Number Of Tests In The Set: 100 Pieces. Complete Set: Quality Control And Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Reagent Information And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks. Storage Conditions And Shelf Life 1. When Sealed: Store At 2 - 8 °C Until Expiration Date. 2. Shelf Life 12 Months. 3. Open At 2-8°C: Stable For At Least 4 Weeks. 4. When Installed In The Analyzer: Stability Is Maintained For At Least 4 Weeks. 5 To Ensure Maximum Quality, It Is Recommended That Opened Kits Be Refrigerated After Assays Performed During The Workday. After The Expiration Date For Open Kits Or Kits Installed In The Analyzer, You Can Continue To Use The Reagent Kit Provided That The Results Obtained Using Control Samples Are Within The Expected Ranges. 6.Store In An Upright Position To Facilitate Proper Re-Suspension Of Magnetic Microparticles. 7. Store In Places Protected From Sunlight. For Manual Work. For Paid Services., Are Intended For Use As A Control Material To Support Quality Assessment Of In Vitro Laboratory Studies, To Verify The Accuracy And Reproducibility Of Procedures, For Analytes Provided In The Instructions, And For Use As A Control Material For Internal Control. For Paid Services. For Manual Work, A Universal Cleaning Reagent Designed For Simultaneous Cleaning Of Counting Chambers And Pipelines From Organic And Inorganic Contaminants. The Reagent Should Not Have A Corrosive Or Oxidizing Effect On The Elements Being Cleaned, And Should Also Be Easily Washed Out. Each Bottle Is 50Ml. This Packaging Is Designed For Convenience And Compatibility With The Length Of The Aspiration Probe During The Analyzer Cleaning Procedure. For Paid Services. For Manual Work, Reagent For The Determination Of Growth Hormone Maglumi Gh (Clia) - Quantitative Test For The Determination Of Growth Hormone (Gh) For The Automatic Chemiluminescent Immunoanalyzer Maglumi (800, 2000, 4000+, X8, X3) Defined Parameters: Gh (Clia) Test Principle: Quantitative For The Determination Of Growth Hormone (Gh) In Human Serum By In Vitro Analysis. Test Method: Chemiluminescent Immunoassay Number Of Tests In The Set: 100 Pieces. Contents Set: Quality Control, Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Reagent Information And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks. Storage Conditions And Shelf Life 1. When Sealed: Store At 2 - 8 °C Until Expiration Date. 2. Shelf Life 12 Months. 3. Open At 2-8°C: Stable For At Least 4 Weeks. 4. When Installed In The Analyzer: Stability Is Maintained For At Least 4 Weeks. 5 To Ensure Maximum Quality, It Is Recommended That Opened Kits Be Refrigerated After Assays Performed During The Workday. After The Expiration Date For Open Kits Or Kits Installed In The Analyzer, You Can Continue To Use The Reagent Kit Provided That The Results Obtained Using Control Samples Are Within The Expected Ranges. 6.Store In An Upright Position To Facilitate Proper Re-Suspension Of Magnetic Microparticles. 7. Store In Places Protected From Sunlight. For Manual Work. For Paid Services., The Reaction Module Is Designed To Carry Out Maglumi Analyzes Using Automatic Chemiluminescent Immunological Analyzer Series Maglumi (Including Models Maglumi 600, Maglumi 800, Maglumi 1000, Maglumi 1000 Plus, Maglumi 2000, Maglumi 2000 Plus, Maglumi 4000 And Maglumi 4000 Plus). Reaction Module: 6×64 (Each With 6 Wells). Additional Information (For Example, Execution Parameters Maglumi Assays. Store At Room Temperature (15–30 °C). For Paid Services. For Manual Work, Reagent For The Determination Of Troponin I Maglumi Troponin I (Clia) - Quantitative Test For The Determination Of Troponin I (Troponin I) For The Automatic Chemiluminescent Immunoanalyzer Maglumi (800, 2000, 4000+, X8, X3) Determined Parameters: Maglumi Troponin I (Clia) Test Principle: Quantitative For The Determination Of Cardiac Troponin I, Often Referred To As Ctni, In Human Serum By In Vitro Assay. Test Method: Chemiluminescent Immunoassay Number Of Tests In The Set: 100 Pieces. Complete Set: Quality Control And Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Reagent Information And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks. Storage Conditions And Shelf Life 1. When Sealed: Store At 2 - 8 °C Until Expiration Date. 2. Shelf Life 12 Months. 3. Open At 2-8°C: Stable For At Least 4 Weeks. 4. When Installed In The Analyzer: Stability Is Maintained For At Least 4 Weeks. 5 To Ensure Maximum Quality, It Is Recommended That Opened Kits Be Refrigerated After Assays Performed During The Workday. After The Expiration Date For Open Kits Or Kits Installed In The Analyzer, You Can Continue To Use The Reagent Kit Provided That The Results Obtained Using Control Samples Are Within The Expected Ranges. 6.Store In An Upright Position To Facilitate Proper Re-Suspension Of Magnetic Microparticles. 7. Store In Places Protected From Sunlight. For Manual Work. For Paid Services., Reagent For The Determination Of Natriuretic Hormone (B-Type) N-Terminal Propeptide (Nt-Probnp) Maglumi Troponin I (Clia) - Quantitative Test For The Determination Of Troponin I (Troponin I) For The Automatic Chemiluminescent Immunoanalyzer Maglumi (800, 2000, 4000+, X8, X3) Determined Parameters: Maglumi Troponin I (Clia) Test Principle: Quantitative For The Determination Of Cardiac Troponin I, Often Referred To As Ctni, In Human Serum By In Vitro Assay. Test Method: Chemiluminescent Immunoassay Number Of Tests In The Set: 100 Pieces. Complete Set: Quality Control And Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Reagent Information And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks. Storage Conditions And Shelf Life 1. When Sealed: Store At 2 - 8 °C Until Expiration Date. 2. Shelf Life 12 Months. 3. Open At 2-8°C: Stable For At Least 4 Weeks. 4. When Installed In The Analyzer: Stability Is Maintained For At Least 4 Weeks. 5 To Ensure Maximum Quality, It Is Recommended That Opened Kits Be Refrigerated After Assays Performed During The Workday. After The Expiration Date For Open Kits Or Kits Installed In The Analyzer, You Can Continue To Use The Reagent Kit Provided That The Results Obtained Using Control Samples Are Within The Expected Ranges. 6.Store In An Upright Position To Facilitate Proper Re-Suspension Of Magnetic Microparticles. 7. Store In Places Protected From Sunlight. For Manual Work. For Paid Services., Reagent For Determination Of Hige. Maglumi Ige (Clia) - Quantitative Test For The Determination Of Immunoglobulin E (Ige) For The Automatic Chemiluminescent Immunoanalyzer Maglumi (800, 2000, 4000+, X8, X3) Determined Parameters: Maglumi Ige (Clia) Test Principle: Quantitative For The Determination Of Immunoglobulin E (Ige) In Human Serum By In Vitro Analysis. Test Method: Chemiluminescent Immunoassay Number Of Tests In The Set: 100 Pieces. Contents Set: Quality Control, Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Reagent Information And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks. Storage Conditions And Shelf Life 1. When Sealed: Store At 2 - 8 °C Until Expiration Date. 2. Shelf Life 12 Months. 3. Open At 2-8°C: Stable For At Least 4 Weeks. 4. When Installed In The Analyzer: Stability Is Maintained For At Least 4 Weeks. 5 To Ensure Maximum Quality, It Is Recommended That Opened Kits Be Refrigerated After Assays Performed During The Workday. After The Expiration Date For Open Kits Or Kits Installed In The Analyzer, You Can Continue To Use The Reagent Kit Provided That The Results Obtained Using Control Samples Are Within The Expected Ranges. 6.Store In An Upright Position To Facilitate Proper Re-Suspension Of Magnetic Microparticles. 7. Store In Places Protected From Sunlight. For Manual Work. For Paid Services., Reagent For The Determination Of Free Triiodothyronine (Free T3) Maglumi Ft3 (Clia) - Quantitative Test For The Determination Of Free Triiodothyronine (Ft3) For The Automatic Chemiluminescent Immunoanalyzer Maglumi (800, 2000+, 4000+, X8, X3) Defined Parameters: Maglumi Ft3 (Clia) Test Principle: Quantitative For The Determination Of Free Triiodothyronine (Ft3) In Human Serum By In Vitro Analysis. Test Method: Chemiluminescent Immunoassay Number Of Tests In The Set: 100 Pieces. Contents Set: Quality Control, Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Reagent Information And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks. Storage Conditions And Shelf Life 1. When Sealed: Store At 2 - 8 °C Until Expiration Date. 2. Shelf Life 12 Months. 3. Open At 2-8°C: Stable For At Least 4 Weeks. 4. When Installed In The Analyzer: Stability Is Maintained For At Least 4 Weeks. 5 To Ensure Maximum Quality, It Is Recommended That Opened Kits Be Refrigerated After Assays Performed During The Workday. After The Expiration Date For Open Kits Or Kits Installed In The Analyzer, You Can Continue To Use The Reagent Kit Provided That The Results Obtained Using Control Samples Are Within The Expected Ranges. 6.Store In An Upright Position To Facilitate Proper Re-Suspension Of Magnetic Microparticles. 7. Store In Places Protected From Sunlight. For Manual Work. For Paid Services., Reagent For The Determination Of Free Thyroxine (Free T4) Maglumi Ft4 (Clia) - Quantitative Test For The Determination Of Free Thyroxine (Ft4) For The Automatic Chemiluminescent Immunoanalyzer Maglumi (800, 2000+, 4000+, X8, X3) Defined Parameters: Maglumi Ft4 (Clia) Test Principle: Quantitative For The Determination Of Free Thyroxine (Ft4) In Human Serum By In Vitro Analysis. Test Method: Chemiluminescent Immunoassay Number Of Tests In The Set: 100 Pieces. Contents Set: Quality Control, Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Reagent Information And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks. Storage Conditions And Shelf Life 1. When Sealed: Store At 2 - 8 °C Until Expiration Date. 2. Shelf Life 12 Months. 3. Open At 2-8°C: Stable For At Least 4 Weeks. 4. When Installed In The Analyzer: Stability Is Maintained For At Least 4 Weeks. 5 To Ensure Maximum Quality, It Is Recommended That Opened Kits Be Refrigerated After Assays Performed During The Workday. After The Expiration Date For Open Kits Or Kits Installed In The Analyzer, You Can Continue To Use The Reagent Kit Provided That The Results Obtained Using Control Samples Are Within The Expected Ranges. 6.Store In An Upright Position To Facilitate Proper Re-Suspension Of Magnetic Microparticles. 7. Store In Places Protected From Sunlight. For Manual Work. For Paid Services., Reagent For The Determination Of Follicle-Stimulating Hormone (Fsh) Maglumi Fsh (Clia) - Quantitative Test For The Determination Of Human Follicle-Stimulating Hormone (Fsh) For The Automatic Chemiluminescent Immunoanalyzer Maglumi (800, 2000, 4000+, X8, X3) Defined Parameters: Maglumi Fsh(Clia) Test Principle: Quantitative For The Determination Of Human Follicle Stimulating Hormone (Fsh) In Human Serum By In Vitro Assay. Test Method: Chemiluminescent Immunoassay Number Of Tests In The Set: 100 Pieces. Contents Set: Quality Control, Upper Calibrator, Lower Calibrator, Buffer Solution. Magnetic Nanoballs Act As The Solid Reaction Phase. The Kit Has An Rfid Tag Containing Reagent Information And A Built-In Calibration Curve. Calibrators Are Used To Adjust The Built-In Calibration Curve At Two Points. Calibration Is Stable For 4 Weeks. Storage Conditions And Shelf Life 1. When Sealed: Store At 2 - 8 °C Until Expiration Date. 2. Shelf Life 12 Months. 3. Open At 2-8°C: Stable For At Least 4 Weeks. 4. When Installed In The Analyzer: Stability Is Maintained For At Least 4 Weeks. 5 To Ensure Maximum Quality, It Is Recommended That Opened Kits Be Refrigerated After Assays Performed During The Workday. After The Expiration Date For Open Kits Or Kits Installed In The Analyzer, You Can Continue To Use The Reagent Kit Provided That The Results Obtained Using Control Samples Are Within The Expected Ranges. 6.Store In An Upright Position To Facilitate Proper Re-Suspension Of Magnetic Microparticles. 7. Store In Places Protected From Sunlight. For Manual Work. For Paid Services., Maglumi Solution For Cleaning System Tubes Is Intended For Cleaning The Pipette Dispenser And The Needles Of The Flushing Unit. He Helps Minimize The Carry-Over Effect By Reducing The Amount Of Protein Drugs In The Tubing And Thereby Optimizing Daily Maintenance Procedures For Maglumi Systems. This Kit Can Only Be Used With Automatic Chemiluminescent Immunological Analyzer (Clia) Of The Maglumi Series (Including Models Maglumi 600, Maglumi 800, Maglumi 1000, Maglumi 1000 Plus, Maglumi 2000, Maglumi 2000 Plus, Maglumi 4000 And Maglumi 4000 Plus). Storage Once Received, Store The Kit At 15-30°C. Do Not Expose To Direct Sunlight. The Shelf Life Of The Solution Is 12 Months. For Paid Services. For Manual Work, Test Strips For The Closed Type Analyzer Eu-5600Pro. Packing: 100 Test Strips In One Tube, 10 Tubes In A Package. Determination Of 14 Analytes. The Time To Determine The Result For All Analytes Is No More Than 60 Seconds. Strict Sequence Of Location Of Test Zones For Each Analyte Being Determined. High Sensitivity For Determining Each Analyte. Determination Parameters: Urobilinogen, Bilirubin, Ketones, Blood (Hemoglobin), Protein, Ph, Specific Gravity, Nitrites, Leukocytes, Glucose, Ascorbic Acid, Ca, Creatinine, Microalbumin. Manufacturer: Shenzhen Mindray Bio-Medical Electronics Co., Ltd. Storage Conditions: From 2 ºc To 30 ºc At A Relative Humidity Of No More Than 93%. Shelf Life 2 Years. For Paid Services. For Manual Work, Light Test Solution Is Required To Check The Suitability Of Starting Reagents 1 And 2 And The Quality Of Operation Measuring And Dosing Devices. The Light Signal Must Be Checked Using An Automatic Chemiluminescent Immunological Analyzer Maglumi Series (Including Models Maglumi 600, Maglumi 800, Maglumi 1000, Maglumi 1000 Plus, Maglumi 2000, Maglumi 2000 Plus, Maglumi 4000 And Maglumi 4000 Plus) Daily Before Carrying Out The First Analysis Procedure Or Each Time Before Using A New Batch Of Starting Reagents. This The Control Procedure Allows You To Check The Correct Operation Of The Analyzer And The Suitability Of Starting Reagents And Thereby Avoid Erroneous Results Due To Analyzer Malfunction, Incorrect Placement Or Expiration Of The Starting Reagents Expiration Date. Storage And Stability The Unopened Bottle Should Be Stored At 2-8°C Until The Expiration Date Stated On The Label. (12 Months From Production Date). After Use, Immediately Close The Light Signal Test Solution Bottle And Store It In A Safe Place. Refrigerator At 2–8 °C. Do Not Expose To Direct Sunlight. After Opening The Bottle With The Solution. For Paid Services. For Manual Work