GTR 114006093

Bids Are Invited For Hiring A Service For Continuous Monitoring Of The Cold Chain (Temperature And Humidity) In Chambers And Vaccine Rooms, Includes Licensing Software With Access Via Mobile Application, Issuing Alerts, Maintaining Records And Providing Equipment On Loan.

ICB — International Competitive Bid Closed South America
Tender Information
GTR Reference
114006093
Tendering Authority
Subscribe to view
Tender No
551/2026
Financer Name
Self-Funded
Work Title
Bids Are Invited For Hiring A Service For Continuous Monitoring Of The Cold Chain (Temperature And Humidity) In Chambers And Vaccine Rooms, Includes Licensing Software With Access Via Mobile Application, Issuing Alerts, Maintaining Records And Providing Equipment On Loan.
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
15-06-2026 Closed
Work Detail
Computer Systems Management Services Remote Monitoring Service For Temperature And Humidity In Chambers And Vaccination Rooms, With A Monitoring Application Compatible With The Android System For 24-Hour Monitoring With The Issuance Of Immediate Alerts In The Event Of Temperature Deviations, Storage Of Records In The Cloud, Generation Of Reports For Audits And Maintenance Of Records Even In Cases Of Power Outages; The System Must Be Installed In 24 Vaccine Chambers - Consisting Of Hardware Supplied For Free, Installed Inside And Outside The Chambers, Capable Of Simultaneously Measuring The Internal Temperature (Immersion Probe From -55°C To +125°C) And The External Environment Parameters, Operating Via Wi-Fi Network And Having A Redundancy System With Internal Battery (Nobreak) That Ensures Continuous Measurement By 10 To 12 Hours In Cases Of Electrical Failure.With External Temperature Measurements: From - 40°C To +80°C (Celsius) Relative Humidity (Rh): From 0% To 100% Ur, With Temperature Accuracy: 0.5°C, Humidity Accuracy: 2% (Can Be 5% At Maximum/Minimum Limit). And With Internal Temperature Measurements: With Accuracy: 0.5°C In The Range From -10°C To +85°C, Measurement From - 55°C To +125°C. Exclusively In-Person Training And Practical Training For Users And Operators On The Functioning Of The System, On The Use Of The Monitoring Application, And Other Functionalities Relevant To The System In The Respective Health Centers., Computer Systems Management Services Physical Installation Service And Configuration Of The Equipment Required For Monitoring.
Key Value
Tender Value
57,840 - BRL
Tender Documents
Global Tender Document
6d27d83e-3051-4e40-8bef-1c5caf832908.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders