GTR 113882395
Request For Quotation Consumables For The Roche Diagnostics Cobas Pure Analyzer
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
113882395
Tendering Authority
Subscribe to view
Tender No
17108318
Financer Name
Self-Funded
Work Title
Request For Quotation Consumables For The Roche Diagnostics Cobas Pure Analyzer
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
04-06-2026
Closed
Work Detail
System Cleaning Solution Ise Sys Clean 5*100 Purpose: For Cleaning Ise Analytical Units On Closed-Type Cobas 6000 Analyzers. For Cleaning Closed-Type Cobas 6000 Immunochemical Analyzers. The Ise Cleaning Solution / Sysclean Is An Alkaline Cleaning Solution With Antimicrobial Properties. Reagents - Working Solutions: 5 Bottles, Each 100 Ml. Components: Sodium Hydroxide, 3 Mol/L Sodium Hypochlorite Solution (< 2% Active Chlorine), Additive. Storage And Stability: Store In A Dark Place. The Solution Is Stable Until The End Of The Stated Shelf Life When Stored At 2‑8 °C. If The Product Does Not Meet The Technical Specifications, Replace The Product Within 3 Days After Notification “Agree With The Customer +7 775. 487 3003, Reagents For The Cobas Pro/Pure Analyzer. Preclean M Solution 2X2l. Preclean M Is Used To Remove Potentially Hazardous Substances Before Signals Appear - The Last Step Of The Analytical Procedure. Reagents And Working Solutions: 2X2l Of Washing Solution Phosphate Buffer 10 Mmol/L; *Sodium Chloride 20 Mmol/L; Detergent ≤ 0.1%; Preservative; Ph 7.0. Conditions Of *Wounding And Transportation: *Wound At Room Temperature In A Strictly Vertical Position. Shelf Life At 15-25 °C See Expiration Date On Kit Label. If The Product Does Not Meet The Technical Specifications, The Product Will Be Replaced Within 3 Days After Notification. Reagent Identification Using Rfid Chip. Each Bottle Must Have An Rfid Tag With Coding Information. Before Delivering The Reagent, Update The Analyzers Reagent Database. The Update Is Carried Out Only With Original Software And A Specialist Who Has Been Trained At The Manufacturer, Has A Training Certificate And A Power Of Attorney From The Manufacturer To Carry Out The Work. The Supplier Must Have All The Material And Technical Base, As Well As Current Access Codes To Carry Out The Work. To Agree With The Customer +7 775 487 3003
Key Value
Tender Value
1,571,116 - KZT
Tender Documents
Global Tender Document
a45f2274-fe47-4187-820a-27c81f5fc4b6.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.