GTR 113755253
Request For Quotation 01. Access Control And Management System Equipment. (1) (Z.457) (Z.290)
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
113755253
Tendering Authority
Subscribe to view
Tender No
17092913
Financer Name
Self-Funded
Work Title
Request For Quotation 01. Access Control And Management System Equipment. (1) (Z.457) (Z.290)
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
03-06-2026
Closed
Work Detail
Iae. A Receiving And Control Device For Controlling Automatic Fire Extinguishing Equipment And Alarms, Designed For Receiving, Processing And Recording Signals From Security And Fire Detectors, Monitoring The Status Of Alarm Loops, Generating Alarm Signals And Transmitting Notifications To A Centralized Monitoring Console, As Well As For Integration Into Complex Security Systems. Monitoring The Status Of Security And Fire Alarm Loops. Reception Of Signals “Alarm”, “Fire”, “Fault”. Event Registration And Storage In Non-Volatile Memory. Transmission Of Notifications To The Central Monitoring Console. Monitoring Communication Lines For Breaks And Short Circuits. Support For Various Types Of Detectors (Security, Fire, Combined). Light And Sound Indication Of States. Control Of Case Opening (Tamper). Possibility Of Integration Into Dispatch And Monitoring Systems. Number Of Alarm Loops: At Least 20. Types Of Loops: Security, Fire, Combined. The Number Of Connected Detectors Is Determined By The Parameters Of The Loops, At Least 20 Zones. Communication Interfaces: Rs-485 (For Integration Into The System). Event Log Of At Least 1000 Entries. Power Supply 220 V Ac. Backup Power From A 12 V Battery. Power Consumption No More Than 30 W. Indoor Installation. Operating Temperature: –10 °C To +50 °C. Relative Humidity Up To 93% Without Condensation. Wall Mounting. Non-Volatile Memory. Led Status Indication. Protection Against Unauthorized Access. Built-In Power Supply (If Available). Possibility Of Connecting External Devices. St Rk 51089-2003. Operation Manual. Warranty Card (Warranty Period Of At Least 12 Months). Certificate., Iae. Server Cabinet Height 18U. Functional, Technical, Operational, Quality Characteristics: Designed For Placement, Installation And Protection Of Server, Network And Telecommunications Equipment In Offices, Data Centers And Server Rooms. Functionality: Ensuring Stable Fixed Installation Of Standard 19‑Inch Equipment; Protecting Equipment From Mechanical Influences, Dust And Foreign Objects Due To The Closed Housing; Ensuring Internal Ventilation Volume And Heat Dissipation; Possibility Of Installing Accessories (Shelves, Pdus, Fans, Etc.); Removable Side Panels For Easy Access; Front Glass Door For Visual Control Of Installed Equipment; Main Characteristics: Capacity (Units) 18U; Load Capacity (Max.) No More Than 800 Kg; 600 × 987; Case Material: Cold-Rolled Steel Spcc Case Thickness, Not Less Than 2.0 Mm, Thickness Of The Supporting Structure, Not Less Than 1.2 Mm; Front Door Material, Tempered Glass, Installation Method: Floor-Mounted. Standard Equipment: Shelf, At Least 1 Pc., Fans, At Least 2 Pcs. Front Door Rotation Angle More Than 180°. Warranty Card (Warranty Period Of At Least 12 Months)., Iae. Access Controller For The Access Control And Management System (Acs). Functional, Technical, Quality, Operational Characteristics: Designed For Organizing Access Control In Premises, Controlling Electromagnetic And Electromechanical Locks, Turnstiles, Barriers, As Well As For Integration Into Complex Security Systems. Functionality: Management Of One Access Point (One Door - Entry/Exit); Support For Working With Readers Via The Wiegand Interface; Identification By Card, Card + Pin Code (When Using Keypad Readers); Storing The User Database And Events In Non-Volatile Memory; Registration Of Passages And Events (Access Allowed/Denied, Opening Of The Case, Etc.); Support For Modes: “Free Passage”, “Closed”, “Scheduled”; Door Status Monitoring (Position Sensor); Exit Button Control; Control Of Case Opening (Tamper); Possibility Of Integration Into A Security Alarm System. Number Of Connected Readers: At Least 2 (Input/Output); Reader Connection Interface: Wiegand (26/34 Bit) Or Equivalent; Communication Interface With The System: Rs-485; Number Of Controlled Actuators: At Least 1 (Electromagnetic Or Electromechanical Lock); Number Of Users: At Least 2000; Number Of Events In Memory: No Less Than 32,000; Power Supply: Supply Voltage, Not Less Than: 12 V Dc; Current Consumption: No More Than 200 Ma (Excluding Actuators); Performance Characteristics: Installation: Indoors; Operating Temperature: –10 °C To +50 °C; Relative Humidity: Up To 93% Non-Condensing; Installation: Wall-Mounted, In A Low-Current Cabinet Or Housing; Design Features: Non-Volatile Memory; Led Status Indication; Protection Against Unauthorized Opening; Compatible With Access Control And Security Alarm Equipment Of A Similar Class. Warranty For At Least 12 Months. Certificate., Iae. Reader For Access Control And Management System. Contactless Access Control Card Reader. Purpose: User Identification Using A Contactless Card/Key Fob For Access Control And Management Subsystems (Acs), Data Transfer To The Access Controller. Identification Type: Contactless User Identification Using Rfid Tags/Cards; Supported Card Standards: Em-Marine (125 Khz) Or Equivalent Contactless Rfid Standard; Operating Frequency: Not Less Than 125 Khz; Reading Range: At Least 3–8 Cm (Depending On The Cards/Keyfobs Used And Installation Conditions); Data Transmission Interface: Wiegand (26/34 Bit) Or Equivalent Digital Interface For Connection To Acs Controllers; Indication: Light (Led) With Indication Of Reading Status And Errors; Sound (Built-In Sound Signal). Case Type: Wall-Mounted/Overhead; Case Material: Durable, Impact-Resistant Plastic And/Or Metal; Degree Of Protection: No Less Than Ip54. Operating Temperature Range: From –30 °C To +50 °C; Operating Humidity: Up To 95% Without Condensation; Anti-Vandal Properties: Tamper-Resistant Design, With Tamper Output/Tamper Sensor (If Equipped). Supply Voltage: 12 V Dc ±10%; Power Consumption: No More Than 200 Ma; Compatibility: Must Be Compatible With Acs Controllers That Support The Wiegand Interface Or An Equivalent Digital Data Transfer Protocol. Design Requirements: Possibility Of Hidden Cable Laying; Resistance To Climatic And Mechanical Influences; Compact Dimensions, Suitable For Standard Mounting Boxes; Case Color: Grey/Black. St Rk 1699-2007. Certificate., Iae. The Media Converter Is Unmanaged. Functional, Technical, Quality And Performance Characteristics: Designed To Convert An Ethernet Electrical Signal (Twisted Pair) Into An Optical Signal And Back, For The Purpose Of Transmitting Data Over Long Distances Via A Fiber Optic Line. Conversion Of The Rj-45 Signal Into Optical Fiber, Data Transmission Over One Fiber (Wdm Technology), Transmission Speeds Up To 1000 Mbps, Auto-Negotiation Of Speed And Duplex, Auto Mdi/Mdix Support, Light Indication Of Power And Communication Line Status. Ethernet Interfaces: 1 × Rj-45, 10/100/1000 Mbit/S. Optical Port 1 × Sc/Upc (Single Mode Fiber). Wavelength (Tx/Rx) 1550 Nm / 1310 Nm. Ieee 802.3I…802.3Z Standards. Supply Voltage No More Than 5 V Dc. Power Consumption, No More Than 3.5 W. Overall Dimensions: No More Than: 94.5 × 73 × 27 Mm. Case Material Metal. Operating Temperature, From 0 °C To +50 °C. Supplied Complete With Power Adapter. Installation Guide. Warranty Card (Warranty Period Of At Least 12 Months). Certificate., Iae. Security Radio Wave Detector. Combined Optical-Electronic Security Detector (Passive Infrared + Microwave/Radio Wave Channel). Designed To Detect Intrusion Into A Protected Premises Based On Movement, Using Two Independent Detection Channels (Ir And Microwave), As Well As For Integration Into Security Alarm Systems And Complex Security Systems. Detection Of Human Movement In A Protected Area. Dual Detection Technology (Ir + Microwave/Fg) To Reduce False Alarms. Signal Analysis With Alarm Confirmation Via Two Channels. Protection Against Interference (Electromagnetic, Light). Control Of Case Opening (Tamper). Generating An Alarm When Motion Is Detected. Possibility Of Integration Into Security Alarm Systems And Access Control Systems. Detection Range Of At Least 10–12 M. Viewing Angle Of At Least 90°. Volumetric Detection Zone. Sensor Type Passive Infrared (Pir) + Microwave (Microwave/Fg). Alarm Output: Relay (Nc/Nr). Power Supply Supply Voltage: 9-16 Vdc. Current Consumption Is No More Than 20–30 Ma. Indoor Installation. Operating Temperature: –10 °C To +50 °C. Relative Humidity: Up To 95% Non-Condensing. Wall Mounting, Installation Height From 2–2.5 M. Two-Channel Signal Processing, Temperature Compensation. Adjusting Sensitivity. Led Indication Of Operating Modes. The Presence Of Protection Against Opening The Case. Compatible With Security Alarm Control And Control Devices. St Rk Iec 62642-2-2-2022. Supplied Complete With A Mounting Kit - At Least 1 Piece. Operation Manual. Warranty Card (Warranty Period Of At Least 12 Months). Certificate., Iae. Metal Switchboard Cabinet. Climate Protection Cabinet With Thermal Insulation And Built-In Heating And Ventilation Systems. Designed To Accommodate Electronic, Telecommunications And Other Equipment, Protected From Atmospheric Factors, Low And High Temperatures, Dust, Precipitation, As Well As To Prevent Mechanical Damage To The Equipment Due To Climate Control Of The Internal Space Of The Case. Protection Of Placed Equipment From Low And High Temperatures. Maintains Internal Temperature Within A Specified Range Using A Heater And Fan. Regulation Of The Heater Switch-On Temperature, Regulation Of The Fan Switch-On Temperature, Possibility Of Installing Additional Equipment (Pressure Seals, Sensors, Valves, Etc.). Light Indication And Access Control (Lock, Tamper If Necessary). External Cabinet Dimensions (W×H×D), No Less, Mm 700 × 1000 × 230. Mounting Panel Dimensions (W×H), No Less, Mm 640…650 × 900…1140. Operating Temperature Range From −60 °C To +50 °C. Case Material Steel, Thermal Insulation Foil 10 Mm. The Degree Of Protection Of The Shell Is At Least Ip55. Supply Voltage, No Less Than V ~220 Ac. Heater Power From 300 To 400 W. The Temperature Adjustment Range For Turning On The Heater Is 0…+60 °C. The Fan Switching Temperature Adjustment Range Is 0…+60 °C. Fan Capacity: At Least 50 M³/H. Terminal Block At Least 6 Pcs. Grounding Terminal At Least 1 Pc. Electrical Socket 220 V At Least 1 Pc. Installation Outside Or Inside Buildings (Depending On Installation). Operating Temperature: −60 °C To +50 °C. Wall Mounting Or Using Pole Mounting Kits (Diameter 70...200 Mm). Supplied Complete With A Mounting Panel Of At Least 1 Piece, A Mounting Set Of At Least 1 Piece, A Door Lock Of At Least 1 Piece. Gost Iec 61439-1-2013. Passport/Operation Manual. Warranty Card (Warranty Period Of At Least 12 Months). Certificate., Iae. Uninterruptible Power Supply Backup. Redundant Dc Power Supply Designed For Uninterrupted Power Supply Of Security, Fire, Video Surveillance And Other Low-Power Equipment, Providing Backup Power When The Main Network Is Disconnected And Protecting Connected Batteries From Overcharging, Overload And Deep Discharge. Constant Voltage Support For Equipment From 10 To 13.6 V Dc. Backup Battery Power Supply From 12 To 14 V Dc, Rated Output Current Of At Least 3 A, Short Circuit And Overload Protection, Battery Protection From Over-Discharge And Polarity Reversal. Light Indication Of Network, Load And Battery Status. Sound Signal Of Emergency Conditions. Output “Network Failure” (Open Collector) For Remote Signaling. Ability To Work With Loads With High Starting Currents; Possibility Of Connecting Additional Batteries To Increase Backup Time. Power Supply 150 To 250 V Ac, 50 Hz. Backup Power: 12 V Battery, Capacity From 17 To 34 Ah (One Or Two Batteries). Power Consumption No More Than 30 W. Indoor Installation. Operating Temperature From −10 °C To +40 °C. Wall Mounting. Built-In Power Supply. Led Indication Of Network, Load And Battery Status. Protection Against Unauthorized Access. Possibility Of Connecting External Batteries. Non-Volatile Status Indication. Supplied Complete With A Set Of Mounting Fasteners And Connecting Wires Of At Least 1 Piece. Gost Iec 62040-1-2018. Operation Manual. Warranty Card (Warranty Period Of At Least 12 Months). Certificate., Iae. Magnetic Contact Sensor For Alarm And Fire Alarms. Magnetic Contact Security Detector (Reed Switch); Functional, Technical, Quality, Operational Characteristics: Designed To Monitor The Condition Of Doors, Windows And Other Opening Structures, Generate An Alarm Signal In Case Of Unauthorized Opening And Integrate Into Security Alarm Systems And Access Control Systems. Control Of Opening/Closing Doors And Windows. Generating An Alarm When A Contact Opens; Work As Part Of A Security Alarm System; Possibility Of Integration Into Access Control Systems. Contact Type: Normally Closed (Nc) Or Normally Open (No). Two-Component Sensor (Reed Switch + Magnet); Overlay Installation. Sensing Distance: At Least 15–25 Mm; Connecting Cable Length: At Least 2 M. Voltage At Least 30 V, Current At Least 0.05 A, No Power Required (Passive Device). Indoor Installation. Operating Temperature: –40 °C To +50 °C; Relative Humidity: Up To 95% Non-Condensing. Installation Of An Invoice On Doors, Windows Or Other Structures. Sealed Contact (Reed Switch). Resistance To Mechanical Stress. Supplied Complete With Connection Cable - At Least 1 Pc. Certificate., Iae. Interface Repeater For Receiving And Transmitting Data Packets Via The Rs-485 Or Rs-232 Interface. Rs-485 Interface Converter/Repeater For Security Systems. Functional, Technical, Quality, Operational Characteristics: Designed To Increase The Range Of The Rs-485 Communication Line, Increase The Reliability Of Data Transmission, As Well As For Galvanic Isolation Of Line Segments As Part Of Security, Fire Alarm Systems And Access Control Systems (Acs). Increasing The Range Of The Rs-485 Communication Line; Retransmission And Restoration Of The Signal In The Rs-485 Line; Galvanic Isolation Of Line Segments; Increasing Noise Immunity And Stability Of The System; Dividing The Line Into Independent Segments; Support For Work As Part Of Distributed Security Systems; Real-Time Data Transfer; Indication Of Operating Status And Data Transfer; Possibility Of Integration Into Security And Fire Alarm Systems, Access Control Systems; Number Of Connected Lines: At Least 2 (Rs-485 Input/Output); Connection Interfaces: Interface: Rs-485 (Input/Output); Communication Interface With The System: Rs-485; Transmission Range: Increasing The Total Line Length To At Least 1200 M Per Segment; Number Of Connected Devices: Determined By The Parameters Of The Rs-485 Line, At Least 32 Devices Per Segment; Power Supply: Supply Voltage: 10-28 Vdc; Current Consumption: No More Than 100 Ma. Indoor Installation. Operating Temperature: –10 °C To +50 °C; Relative Humidity: Up To 93% Non-Condensing; Wall, Cabinet Or Din Rail Mounting. Galvanic Isolation Of Interfaces; Led Indication Of Power And Data Transfer; Protection Against Overvoltage And Interference. Compatible With Security System Equipment (Security System, Access Control System, Video Surveillance). Passport/Operation Manual. Warranty Card (Warranty Period Of At Least 12 Months). Certificate., Iae. Rs-232/Rs-485 To Ethernet Interface Converter. Ethernet/Rs-485 Interface Converter For Security Systems. (According To Technical Specification), Iae. Reader For Access Control And Management System. Keyboard Proximity Card Reader For Access Control And Management Systems (Acs). Identification Of Users Using Contactless Cards Of The Em-Marine Standard (125 Khz) And/Or Pin Code, Data Transfer To The Acs Controller. Identification Type: Contactless Proximity Cards; Entering A Pin Code From The Keyboard; Combined Mode “Card + Pin”; Supported Card Standard: Em-Marine (125 Khz) Or Equivalent; Operating Frequency: 125 Khz; Reading Range: No Less Than 5 Cm; Keyboard: At Least 12 Mechanical/Touch Keys; Presence Of Numeric Keys 0–9 And Function Keys; Connection Interface: Wiegand (26/34 Bit); Operation Indication: Led Indication (At Least Two Colors); Sound Indication (Built-In Buzzer); Operational Characteristics: Installation Type: Overhead; Case Material: Impact-Resistant Plastic And/Or Metal; Housing Protection Degree: At Least Ip54; Operating Temperature: From –30 °C To +50 °C; Humidity: Up To 95% Without Condensation; Resistance To External Influences: Protection Against Unauthorized Opening (Tamper), If Available. Power Supply: Supply Voltage: No More Than 12 V Dc; Current Consumption: No More Than 150 Ma; Design Features: Possibility Of Installation Indoors And Outdoors; Compatible With Acs Controllers That Support The Wiegand Interface. St Rk 1699-2007. Certificate., Iae. The Media Converter Is Unmanaged. Functional, Technical, Quality And Performance Characteristics: Designed To Convert An Ethernet Electrical Signal (Twisted Pair) Into An Optical Signal And Back, For The Purpose Of Transmitting Data Over Long Distances Via A Fiber Optic Line. Conversion Of The Rj-45 Signal Into Optical Fiber, Data Transmission Over One Fiber (Wdm Technology), Transmission Speeds Up To 1000 Mbps, Auto-Negotiation Of Speed And Duplex, Support For Auto Mdi/Mdix, Led Indication Of Power And Communication Line Status. Ethernet Interfaces: 1 × Rj-45, 10/100/1000 Mbps, 1 × Sc/Upc Optical Port (Single-Mode Fiber). Wavelength (Tx/Rx) 1310Nm/1550Nm. Ieee 802.3I…802.3Z Standards. Supply Voltage No More Than 5 V Dc. Power Consumption, No More Than 3.5 W. Overall Dimensions: No More Than: 94.5 × 73 × 27 Mm. Case Material - Metal. Operating Temperature, From 0 °C To +50 °C. Supplied Complete With Power Adapter. Installation Guide. Warranty Card (Warranty Period Of At Least 12 Months). Certificate.
Key Value
Tender Value
3,125,800 - KZT
Tender Documents
Global Tender Document
d29deb71-8110-4183-9d8b-1264c31bc749.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.