GTR 113716946

Request For Quotation 01. Purchase Of Fire Safety Goods. (Department 404) - 373

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
113716946
Tendering Authority
Subscribe to view
Tender No
17078658
Financer Name
Self-Funded
Work Title
Request For Quotation 01. Purchase Of Fire Safety Goods. (Department 404) - 373
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
02-06-2026 Closed
Work Detail
Iae. The Luminaire Is Designed To Provide Emergency Backup Lighting In The Event Of A Power Outage. Number Of Leds - At Least 30 Pcs. Energy Efficiency Requirements Are At Least 120 Lm/W. Color Temperature - No Less Than 6500 K. Luminous Intensity - No Less Than 30X2500 Mcd. Light Source Power - At Least 1.5 W. Power Consumption From The Network Is No More Than 0.6 W. Battery Charging Time - 20 Hours. Supply Voltage - From Ac Mains From 187 To 242 V, Frequency 50 Hz. Replaceable Lithium-Ion Battery With A Voltage Of 3.7 V And A Capacity Of 1200 Mah. Overall Dimensions No More Than 202X55x30 Mm. Weight No More Than 0.17 Kg. Operating Temperature Range From - 0 To +40 °C. Gost Iec 60598-2-22-2016. Passport/Operating Manual. Certificate., Iae. Reception And Control Device. Wired Alarm Loops (Al) - At Least 4. Voltage At Each Al Input - 24 V ÷ 19 V When Installing A Resistor. Max. Resistance Of Address Alarm Loop Wires Is 1 Kohm For Security Alarm Loops / 100 Ohm For Fire Alarm Alarm Loops. Ready For Work After Turning On The Power - No More Than 3 Seconds. Current Limitation In A Short-Circuited Loop Is 26.5 Ma (20 Ma Through A Triggered Detector). Non-Volatile Event Buffer - No Less Than 4088. Interface - Rs-485. Outputs - At Least 4 Pcs. The Unit Is Powered From An External Dc Source. Built-In Sound Alarm. The Housing Tamper Sensor Is A Microcontact. Mounting Type: Wall-Mounted, Wall-Mounted Or On A Din Rail. The Degree Of Protection Is At Least Ip30. Average Service Life Is At Least 10 Years. Operating Conditions From -40° To +50 °C; Humidity Up To 98%. Dimensions No More Than 156 X 107 X 39 Mm. Gost 27990-88. Passport/Operating Manual. Certificate., Iae. The Battery Is Intended For Use As A Main Or Backup Power Source In Power Supplies, Office Equipment, And Security Systems. Battery Capacity - 17 A/H, Rated Voltage - 12 V. Dimensions No More Than 181X77x167 Mm (Lxwxh). Gost Iec 60896-2-2002. Certificate., Iae. Speaker, Directional Angle 1Khz / 4 Khz / 8 Khz - 180° / 90° / 80°. Power - No More Than 3 W. Resistance - 8 Ohms. Frequency - 90 Hz - 16 Khz. Degree Of Protection - Ip41. Operating Conditions From -10° To +55 °C. Dimensions No More Than 121 × 121 × 61 Mm. St Rk 1189-2003. Passport/Operating Manual. Certificate., Iae. Fire Detector. Switched Current - Up To 25 Ma, Current Consumption In Standby Mode - No More Than 50 Ma, Installation Type - Wall-Mounted, Mounted. Degree Of Protection - Ip41, Operating Conditions From -30° To +50 °C, Humidity Up To 93%. Dimensions No More Than 95 X 91 X 33 Mm. St Rk 1301-2004. Passport/Operating Manual. Certificate., Iae. The Display Unit Provides Light And Sound Indication Of The Status Of Sections (Zones) And Is Installed Inside The Protected (Protected) Object And Is Designed For Round-The-Clock Operation. Ready For Work After Turning On The Power - No More Than 2 Seconds. Built-In Sound Alarm. Programming The Block Is The Uprog.Exe Program. The Housing Tamper Sensor Is A Microswitch. Communication Port (For Work In Iso Orion) - Rs-485, Orion Protocol. Installation Type: Wall-Mounted, Mounted. Supply Voltage - From 10.2 V To 28.4 V Dc. Degree Of Protection - Ip20. Operating Conditions From -30° To +50°C, Humidity Up To 98%. Dimensions No Less Than 340 X 170 X 25.5 Mm. Gost 27990-88. Passport/Operating Manual. Certificate., Iae. Voice Notification Device. The Main Power Source Is Ac 220 V, 50 Hz. Backup Power Source - Rechargeable Battery 12V, 7Ah. Power Consumed From The Ac Mains Is No More Than 15 W. The Current Consumed From The Backup Power Source In Standby Mode Is No More Than 0.1A. The Average Current Consumption In Alert Mode Is 0.75A. The Units Technical Readiness Time For Operation Is No More Than 3 S. Operating Time From A Fully Charged Battery In Standby Mode Is No Less Than 24 Hours. Operating Time From A Fully Charged Battery In Alert Mode Is No Less Than 2 Hours. Time To Fully Charge A Discharged Battery Is No More Than 60 Hours. Maximum Battery Charge Current Is 0.25A. Maximum Output Power - 40 W. The Permissible Resistance Range Of The Ro Connection Circuit Is From 4 To 22 Ohms. Output Power Limitation Levels - 5. The Total Duration Of Voice Messages Is At Least 84 Seconds. Number Of Messages - No Less Than 128. Non-Volatile Event Buffer - No Less Than 256. Case Tamper Sensor. Communication Port - Rs-485. Electric Shock Protection Class - Ii. The Degree Of Protection Of The Shell Is Ip30. Resistance To Mechanical Stress Corresponds To Placement Category 03. Operating Temperature Range - From -10 To +55 °C. Relative Air Humidity - Up To 98% At +25 °C. Unit Weight (With Battery) - No More Than 2.95. Overall Dimensions Of The Block Are No More Than 211X165x89. St Rk 1189-2003. Passport/Operating Manual. Certificate., Iae. Uninterruptible Power Supply. Redundant Power Supply, Presence Of An Audible Alarm, Number Of Indicators - 3, Battery Voltage Control (Charge Indication), Protection Against Excess Output Voltage - 2 Stages, Maximum Output Current - Not Less Than 2 A, Type Of Installation - Wall-Mounted, Mounted, Rated Output Current - 3 A, Degree Of Protection - Ip30, Operating Conditions From -10° To +40 °C, Humidity Up To 90%, Dimensions Not Over 255 X 310 X 85 Mm. Gost Iec 62040-1-2018. Certificate., Iae. Control And Control Panel. Type Of Connection To The Device - Screw Terminal Block, Wire From 0.2 To 1.5 Sq. Mm. The Number Of Events In The Device Memory Is At Least 8,000. The Unit Is Powered From A Backup Power Source. Built-In Sound Alarm. Number Of Partitions - No Less Than 511. Number Of Partition Groups - No Less Than 128. Number Of User Passwords - No Less Than 2047. Mounting Type - Wall-Mounted, Mounted. Rs-485 Interface. The Number Of Controlled Relay Outputs Is At Least 256. The Number Of Alarm Loops Is At Least 2048. The Length Of The Rs-485 Communication Line Is Up To 3000 M. Rs-232 Interface. The Length Of The Rs-232 Communication Line Is Up To 20 M. Supply Voltage Is From 10.2 V To 28.4 V Dc. Degree Of Protection - Ip30. Operating Conditions From -10° To +55 °C. Dimensions No Less Than 140 X 114 X 25 Mm. Gost 27990-88. Passport/Operating Manual. Certificate.
Key Value
Tender Value
404,300 - KZT
Tender Documents
Global Tender Document
c1c7739b-8a3e-4e1c-a3ea-b4abaaff2b7d.html
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders