GTR 113355010
Request For Quotation Spare Parts For Equipment In The Neonatal Pathology Department
ICB — International Competitive Bid
Closed
Central Asia
Tender Information
GTR Reference
113355010
Tendering Authority
Subscribe to view
Tender No
17038019
Financer Name
Self-Funded
Work Title
Request For Quotation Spare Parts For Equipment In The Neonatal Pathology Department
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
22-05-2026
Closed
Work Detail
Set Of Filters For The Hamilton T1 Device Set Of 5 Filters. The Turbine Dust Filter Is Designed To Pre-Clean The Intake Air From The Environment. The Cooling Fan Filter Provides Protection From Dust To The Internal Components And Electronic Components Of The Device. Must Be Agreed With The Customer. +7 707 783 1177 Department Of Neonatology, The Expiratory Valve Membrane Is Designed For Use As Part Of The Reusable Exhalation Valve Of The Hamilton T1 Ventilator And Ensures Correct Separation Of The Inspiratory And Expiratory Phases, As Well As Maintaining The Set Pressure Level (Peep). The Product Must Be Fully Compatible With The Original Hamilton T1 Expiratory Valve And Not Require Additional Adapters During Installation. The Membrane Is Made Of Medical Elastomer Material, Providing High Tightness, Resistance To Deformation And Stable Performance During Repeated Use. Must Withstand Sterilization Cycles (Including Autoclaving) Without Loss Of Functionality. Provides Low Flow Resistance And Precise Operation Of The Valve Mechanism. Delivery Is Carried Out In A Package Of 5 Pieces. Products Must Be New, Without Traces Of Use, With A Confirmed Expiration Date. Membranes Must Comply With International Quality And Safety Standards (Iso, Ce If Available) And Be Approved For Use In The Territory Of The Republic Of Kazakhstan Or The Eaeu. Must Be Agreed With The Customer. +7 707 783 1177 Department Of Neonatology, Exhalation Valve (Expiratory Valve) Reusable For Hamilton T1 Ventilator Purpose The Expiratory Valve Is Designed To: Regulate The Flow Of Exhaled Gas, Maintain A Given Level Of Positive End-Expiratory Pressure (Peep), Separate The Respiratory Phases (Inhalation/Exhalation), Protect The Internal Components Of The Device From Contact With The Exhaled Gas Of The Patient Compatibility Full Compatibility With The Hamilton T1 Ventilator, Compatibility With Systems: Hamilton C1 / T1 / Mr1, Support For Working With Patients: Neonatal (Depending On From Version - Neonatal) Product Type Type: Reusable (Reusable / Autoclavable) Possibility Of Sterilization: Autoclaving Design: Dismountable Must Be Agreed With The Customer. +7 707 783 1177 Neonatology Department, The Disposable Flow Sensor Kit (Neonatal) Is Designed To Measure Respiratory Parameters In Newborn Patients When Working With The Hamilton T1 Ventilator. Provides Accurate Flow And Tidal Volume Measurements At Low Tidal Volumes Typical Of Neonatal Ventilation. Sensors Must Be Fully Compatible With The Hamilton T1 Device, Installed Without The Use Of Additional Adapters And Ensure Correct Data Transfer To The Device’S Monitoring System. Type - Proximal Flow Sensor, Installed Close To The Patients Airway. The Product Is Disposable, Does Not Require Sterilization And Must Be Disposed Of After Use. The Sensor Design Must Provide High Measurement Accuracy, Low Flow Resistance And Minimal Dead Space, Which Is Critical For Neonatal Patients. Materials Must Be Biocompatible, Safe And Free Of Toxic Components. Delivery Is Carried Out In Packs Of 10 Pieces. Products Must Be New, Sterile (If Necessary), With A Confirmed Expiration Date. Sensors Must Comply With International Quality And Safety Standards (Iso, Ce If Available) And Be Approved For Use In The Territory Of The Republic Of Kazakhstan Or The Eaeu. Must Be Agreed With The Customer. +7 707 783 1177 Neonatology Department, Hepa Filter For Hamilton T1 Device. Hepa Filter For Hamilton /T1/C1 Devices Hepa Filter Intake Air Filter. The Filter Is Designed For Fine Purification Of Air Taken From The Environment. It Consists Of A Special Material, The Fibers Of Which Are Arranged In Such A Way As To Trap Pollutant Particles From The Air. Hepa Filters Purify The Air From 99.95% To 99.995% Of Particles. Must Be Agreed With The Customer. +7 707 783 1177 Neonatology Department, Oxygen Sensor Galvanic Type Oxygen Sensor Is Designed To Determine The Actual Oxygen Concentration In The Inhaled Mixture. Measuring Range 0% To 100% O2. Accuracy And Repeatability < 1% O2 Volume When Calibrated To 100% Oxygen. Linearization Error < 3% Relative. Response Time < 12 Seconds To 90% Of Final Value. Crosstalk. Meets The Requirements Of Iso 80601-2-55. Influence Of Humidity -0.03% Relative In %Rh At 25°C. Impact Of Mechanical Shock < 1% Relative After Falling From A Height Of 1 Meter. Temperature Compensation Built-In Ntc Compensation. Long Term Yield Bias < 1% Oxygen Volume Per Month Typically < -15% Relative Over Service Life. Storage Temperature: -20°C To +50°C. Lasts For Life. Maximum Storage Life From +5°C To +15°C. Warm-Up Time < 30 Minutes After Sensor Replacement. Rated Sensor Life ≥ 1,000,000% Volume Hours Oxygen. All Specifications Apply To Standard Conditions: 1013 Hpa; 25°C Dry, Ambient Air. Must Be Agreed With The Customer.+7 707 783 1177 Gost 31513-2012 Department Of Neonatology, Lithium Ion Battery For Autonomous Power Supply Of The Hamilton T1 Ventilator For Uninterrupted Operation When Transporting Patients And In Conditions Where There Is No External Power Supply. 100% Compatible With The Hamilton T1 Device, Ensure Correct Integration With The Control And Charge Indication System, And Also Support The Normal Operating Modes Of The Device Without Restrictions On Functionality. Rechargeable Type (Li-Ion), With The Possibility Of Multiple Charge/Discharge Cycles Without Significant Loss Of Capacity. Battery Life Of The Device Is At Least 4–9 Hours Depending On The Ventilation Mode And Operating Conditions, With The Possibility Of “Hot-Swap” Without Turning Off The Device. Design In The Form Of A Removable Module With A Reliable Fixation Mechanism And Protection Against Incorrect Installation. The Rated Voltage And Capacitance Must Meet The Requirements Of The Device Manufacturer For Various Loads. Battery With Built-In Management System (Bms), Automatic Cell Balancing And Battery Condition Monitoring. Housing Materials Must Meet Medical Requirements For Safety And Biocompatibility. Maintaining Charging Both As Part Of The Device And Using Standard Chargers, While The Full Charging Time Should Not Exceed The Values Set By The Manufacturer. Providing An Indication Of The Charge Level And Battery Status On The Device Display. Efficiency During Operation In Conditions Of High Humidity And Temperature, Typical For Medical Institutions And Transportation. The Battery Life Is At Least 300–500 Charge/Discharge Cycles While Maintaining The Declared Characteristics. Compliance With International Quality And Safety Standards, Iso Requirements And Ce Marking, As Well As Having Registration And Permission For Use In The Republic Of Kazakhstan Or The Eaeu. Battery With Confirmation Of Expiration Date And Be Equipped With The Necessary Technical Documentation. Must Be Agreed With The Customer. +7 707 783 1177 Neonatology Department
Key Value
Tender Value
1,545,000 - KZT
Tender Documents
Global Tender Document
926f9621-fe8e-4454-86b1-620e10dca6ac.html
Attachments
Additional Details Available on Click
- Tendering Authority
- Publication Document (Tender Document / Tender Notice)
Disclaimer
We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.