GTR 113088902

Bids Are Invited For Hiring A Company To Provide Central Air Conditioning System Installation Services - Indirect Expansion (Chilled Water), Including The Acquisition Of Air Conditioning Equipment, Pipes, Ducts And All Necessary Components For Its Operation, (Re)Adequacy Of The Systems Existing Hydraulic And Electrical, Which Must Be Delivered And Installed At The New Headquarters Of Seplan-Pi, Located In Teresina / Pi, In Accordance With This Document And The Specification Booklet

ICB — International Competitive Bid Closed South America
Tender Information
GTR Reference
113088902
Tendering Authority
Subscribe to view
Tender No
012/2026/2026
Financer Name
Self-Funded
Work Title
Bids Are Invited For Hiring A Company To Provide Central Air Conditioning System Installation Services - Indirect Expansion (Chilled Water), Including The Acquisition Of Air Conditioning Equipment, Pipes, Ducts And All Necessary Components For Its Operation, (Re)Adequacy Of The Systems Existing Hydraulic And Electrical, Which Must Be Delivered And Installed At The New Headquarters Of Seplan-Pi, Located In Teresina / Pi, In Accordance With This Document And The Specification Booklet
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
South America
Political Region
BRIC,G20
Last Date of Bid Submission
01-06-2026 Closed
Work Detail
Chiller Type Water Cooler, Effective Capacity 87Tr, Two Refrigeration Circuits, Scroll Compressors 380V - 3F - 60Hz - Direct Start - Cu/Cl Condenser - With Gold Fin Protection On The Coil, Refrigerant Gas 410A, Electrical Power 118, 79Kw - Water Flow 49, 75M3/H - Loss Of Load 4.55Mca. Model 30Rsb1002c-S, Carrier Manufacturer, Installation Accessories, Vortex Type Cabinet, Nominal Capacity 20Tr, Vertical Mounting And Discharge Position, Right Hydraulics Side, Air Flow Of 12,150M3/H - Water Flow Of 5.94M3/H - Temp. Water Inlet/Outlet: 7°C/12.5°C - Filters G4 + M5 - Motor 6.0Hp - External Pressure: 20Mmca - 380V/3F/60Hz - 4Poles - Model 39V20a - Manufacturer Carrier, Nominal Capacity 25Tr, Air Flow Of 11.400M3/H - Water Flow Of 18, 07M3/H - Temp. Water Inlet/Outlet: 7°C/12.5°C - Filters G4 + M5 - Motor 4.0Cv - External Pressure: 25Mmca - 380V/3F/60Hz - 4Poles - Model 39V25c - Carrier Manufacturer, Hydronic Fanvest, 1-Way Cassette Type, Unit Capacity 9,600But/H - Water Flow Air Of 510M3/H - Water Flow Of 0.50M3/H. Temp. Water Inlet/Outlet: 7°C/12.5°C - 0.032Kw Motor - 220V/1F/60Hz - External Static Pressure 0.0Mmca. G0 Filtration - Model 40Hkv10 - Carrier Manufacturer, Unit Capacity 12.001But/H - Air Flow Of 630M3/H - Water Flow Of 0.65M3/H. Temp. Water Inlet/Outlet: 7°C/12.04Kw - 220V/1F/60Hz - External Static Pressure 0.0Mmca - G0 Filtration - Model 40Hkv12 - Manufacturer Carrier, 4-Way Cassette Type, 05Kw - 220V/1F/60Hz - External Static Pressure 0.0Mmca - G0 Filtration - Model 40Hk10 - Carrier Manufacturer, Unit Capacity 12.001But/H - Air Flow Of 680M3/H - Water Flow Of 0.648M3/H - Water Input/Output Temp: 7°C/12.07Kw - 220V/1F/60Hz - External Static Pressure 0.0Mmca - G0 Filtration - Model 40Hk12 - Manufacturer Carrier, Unit Capacity 15,601But/H - Air Flow Of 850M3/H - Water Flow Of 0, 792M3/H - Water Input/Output Temp: 7°C/12, 095Kw - 220V/1F/60Hz - External Static Pressure 0. 0Mmca - G0 Filtration - Model 40Hk16 - Manufacturer Carrier, Unit Capacity 20.401But/H - Air Flow Of 1.340M3/H - Water Flow Of 0.90M3/H - Water Input/Output Temp: 7°C/12.11Kw - 220V/1F/60Hz - External Static Pressure 0, 0Mmca - G0 Filtration - Model 40Hk20 - Carrier Manufacturer, Unit Capacity 25,201But/H - Air Flow Of 1,420M3/H - Water Flow Of 1, 11M3/H - Water Input/Output Temp: 7°C/12, 15Kw - 220V/1F/60Hz - Static Pressure External 0.0Mmca - G0 Filtration - Model 40Hk25 - Manufacturer Carrier, Unit Capacity 32.401But/H - Air Flow Of 1.920M3/H - Water Flow Of 1.44M3/H - Water Input/Output Temp: 7°C/12.19Kw - 220V/1F/60Hz - Pressure External Static 0.0Mmca - G0 Filtration - Model 40Hk32 - Carrier Manufacturer, Unit Capacity 42.002But/H - Air Flow Of 2.250M3/H - Water Flow Of 2.23M3/H, Water Inlet/Outlet Temp: 7°C/12.0Mmca - G0 Filtration - Model 40Hk42 - Carrier Manufacturer, Floor/Ceiling Type, Unit Capacity 14.401But/H - Air Flow Of 637M3/H - Water Flow Of 0.72M3/H. Temp. Water Input/Output: 7°C/12.08Kw - 220V/1F/60Hz - External Static Pressure 0.0Mmca - G0 Filtration - Model 40Ls14 - Carrier Manufacturer, Built In Type, Unit Capacity 24.001But/H - Air Flow Of 1.133M3/H - Water Flow Of 1.332M3/H - Water Inlet/Outlet Temp: 7°C/12.26Kw - 220V/1F/60Hz - External Static Pressure 0.0Mmca - G0 Filtration - Model 42Bba024 - Carrier Manufacturer, Unit Capacity 44.402But/H
Key Value
Tender Value
Ref. Document
Tender Documents
Global Tender Document
1410928e-c255-404b-b860-02facec13428.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders