The Subject Of The Order Is The Modernization Of The Running Track And Tennis Courts Located On The Premises Of The Lxx Secondary School At Ul. Dembowskiego 1 In Warsaw. The Track And Courts Will Have A New Polyurethane Surface. The Tennis Court Net Will Be Replaced With A New One. 6.1. General Informationthe Running Track And Courts Are Located At Ul. Dembowskiego 1 In Warsaw, On Plots No. 6/6, 6/7 And 6/8, District 1-10-16. The Plots Are Owned By The Capital City Of Warsaw. Warsaws Ursynów District. Teren Jest Ogrodzony. Entrance And Entrance From The North-Eastern Side, From The Municipal Road Ul. Service Poland And The Southern One From The Internal Road From Ul. Dembowskiego. Numerical Data: - Area Of The Renovated Pitch 1,348.20 M2 - Area Of The Renovated Running Track 593.80 M26.2. Scope Of The Order• Preparation Of The Construction Site And Cleaning Of The Area;• Protection Of Trees For The Duration Of Construction Works;• Replacement Of The Tennis Court Net - 5X5 Cm Steel Mesh Instead Of Nylon Mesh;• Dismantling Of The Existing Running Track And Tennis Courts Surface Along With The Sbr Layer;• Dismantling Of The Foundation Layers;• Mechanical Profiling And Compaction Of The Subgrade For The Construction Layers;• Loading, Removal And Disposal Of Demolition Materials;• Execution Base Layers;• Construction Of A Polyurethane Spray Surface, Brick Red Ral 3016 With A Dynamic Et Base, 3.5 Cm Thick, Along With Painting The Lines;• Replacement Of The Linear Drainage Grid (Courts) On The Existing Drainage Systems;• Removal Of Trees And Stumps In Accordance With Annex No. 5 To The Opz;• Construction Of 3 Coniferous Tree Plantings (Replacement Plantings) Of Trees With A Circumference Trunk At A Height Of 100 Cm, Not Less Than 18-20 Cm And A Height Of At Least 180 Cm, Together With Staking And Mulching In Properly Prepared Ground In The Place Indicated By The Ordering Party And The User Of The Facility In Accordance With Annex No. 5 To The Opz;• Reconstruction Of Damaged Lawns During The Works. Note: The Scope Of The Order Does Not Include The Scope Of Works Included In The Design Documentation Regarding The Electrical Installation In The Scope Of Replacing Fixtures Oświetleniowych.6.3. Minimum Pavement Parameters To Maintain Appropriate Quality And Durability, The Pavement Should Have Parameters No Worse Than Those Described Below (Wherever The Opz Mentions Standards, The Ordering Party Also Allows Equivalent Ones): 1. Surface Thickness (Mm) ≥ 132. Tensile Strength, N/Mm2 (Mpa) ≥ 1.13. Relative Elongation At Break % ≥754. Shock Absorption, Force Reduction, On Concrete Surface (23°C) % 35-445. Vertical Deformation, On Concrete Surface (23°C), Mm ≤1.76. Abrasion Resistance In The Taber Apparatus, G ≤0.67. Resistance To Artificial Aging Assessed By Color Change -8. Degree On The Gray Scale (Pn-En 20105-A02:1996 Tests) ≥49. Sliding Resistance, Pendulum Test, Cen Slider, C Scale, Ptv Units Dry Surface 80-110 Wet Surface 55- 11010. Water Infiltratio
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.