Professional Technical Services For Obtaining The Avcb With The Fire Department For Buildings Up To 2000 M², Professional Technical Services For Obtaining The Avcb With The Fire Department For Buildings From 2001 To 5000 M², Development Of A Technical Project For Fire Prevention And Fighting And Approval With The Fire Department For Buildings Up To 2000 M², Project Development Fire Prevention And Fighting Technician And Approval With The Fire Department For Buildings From 2001 To 5000 M², Identification Plate For Work, Fire Extinguisher With Dry Chemical Powder Charge - 4Kg, Fire Extinguisher With Carbon Gas (Co2) Charge 6Kg, Fire Extinguisher With Pressurized Water Charge - 10L, Photoilluminant Pvc Signage Plate (240X120mm), With Evacuation Route And Emergency Exit Indication, Pvc Identification Plate With Vinyl Text, Photoilluminant Pvc Signage Plate (200X200mm), With Alarm, Detection And Fire Extinguishing Equipment Indication, Photoilluminant Pvc Signage Plate (150X150mm) Shielded 2X2, 5Mm², 600V Insulation Insulation In Vc/E 105ºc - For Fire Detection, Metal Passing Box, With Screwed Cover, 100X100x80mm, Thermomagnetic Mini-Circuit Breaker, Bipolar 220/380 V, Current From 10A To 32A, 12 Horn Siren V, Complete Fire Detection And Alarm Central, Autonomy Of 1 Hour For 12 Loops, 220 V/12 V, Push Button For Activating A Glass Breaker Type Fire Pump, 600V Insulation, Insulation At Vc/E 105ºc - For Fire Detection, Plumber Or Hydraulic Firefighter With Additional Charges, Assistant Plumber Or Hydraulic Firefighter With Additional Charges, Complete 2 1/2 Hydrant Shelter - Including 30M Hose (2X15m), Galvanized Steel Tube With Seam, Medium Class, Dn 65 (2 1/2), Threaded Connection, Installed On Hydrant Supply Network - Supply And Installation. Af 10/2020, Sleeve, In Galvanized Iron, Tee, 90 Degree Elbow, Installed In Building Water Reservoir - Supply And Installation Af 04/2024, Nipple, Shelter For Column Type Pressure Registration, Complete - Including Pipes And Valves, Polyethylene Reservoir With Snap-On Lid - Capacity Of 10.00 Liters, Manual Landfill Of Trenches With Sand For Landfill Af 08/2023, Lean Concrete For Ballast, Ratio 1:4, 5:4, 5 (In Dry Mass Of Cement/Medium Sand/Gravel 1) - Manual Preparation Af 05/2025, Floor With Simple Concrete Frame With Control Of Fck=20 Mpa, Thermomagnetic Circuit Breaker, Current Up To 60A 100A, On-Off Control Button, Without Signaling, Cast Aluminum Housing Proof Weather, Moisture, Gases, Vapors And Dust, 445X350x220mm, Electronic Time Relay From 0. 6 To 6S - 220V - 50/60 Hz, Adjustable Current Relay From 0 To 200A, Contactor Power 65A - 2Na +2Nf, Type Bnc Terminal Connector For Rg 59 Coaxial Cable, 1 Copper Cable, 0.6/1 Kv Insulation - 70ºc Pvc Insulation, 3X1.5 Mm² Flexible Copper Cable, 6/1 Kv - 90ºc Hepr Insulation, 10Mm² Copper Cable, 750 V Insulation - 70ºc Pvc Insulation, Lightweight Flexible Corrugated Pvc Conduit, 20 Mm External Diameter, Cast Iron Loose Flange, Class Pn-10,