GTR 112846966

Request For Quotation 01. Purchase Of Fire Safety Goods. (Department 404) - 373

ICB — International Competitive Bid Closed Central Asia
Tender Information
GTR Reference
112846966
Tendering Authority
Subscribe to view
Tender No
16960873
Financer Name
Self-Funded
Work Title
Request For Quotation 01. Purchase Of Fire Safety Goods. (Department 404) - 373
Bid Type
ICB — International Competitive Bid
Country
Subscribe to view
Geographical Region
Central Asia
Political Region
Commonwealth of Independent States, CIS
Last Date of Bid Submission
14-05-2026 Closed
Work Detail
Iae. Cable Channel. Functional, Technical, Quality And Performance Characteristics. Designed For Laying Power Cables And Low-Current Networks For Outdoor Installation Indoors. Dimensions No More Than (Hxw) 10X15 Mm, Length No Less Than 2000 Mm. Color - White, System Type - Mounting Tray, Case Material - Plastic, Installation Method - Overhead. Certificate., Iae. The Battery Is Intended For Use As A Main Or Backup Power Source In Power Supplies, Office Equipment, And Security Systems. Battery Capacity - 17 A/H, Rated Voltage - 12 V. Dimensions No More Than 181X77x167 Mm (Lxwxh). Gost Iec 60896-2-2002. Certificate., Iae. Addressable Smoke Fire Detector, Detector Technical Readiness Time - No More Than 60 S, Detector Programming - Uprog.Exe Program, Device Power Supply - Up To 11 W, Current Consumed By The Detector - Not Less Than 0.5 Ma, Detector Sensitivity - From 0.05 To 0.2 Db/M, Mounting Type - Ceiling, Degree Of Protection - Ip41, Operating Conditions From -30° To +55 °C, Dimensions: Diameter No More Than 100 Mm, Height No More Than 47 Mm. St Rk 1234-2004. Passport/Operating Manual. Certificate., Iae. The Fire Alarm Cabinet Is Designed For Group Power Supply Of Fire Automatic Devices Placed In It, Detectors And Fire Alarm Control Panels And Other Equipment That Requires Backup Power Supply With A Voltage Of 24V Dc. Rated Switching Current Is Not Less Than 2 A. Installation Type - Wall-Mounted, Suspended. Degree Of Protection - Ip40. Operating Conditions From -30° To +50 °C. Dimensions No More Than 650 × 500 × 220 Mm. Gost Iec 61439-1-2013. Passport/Operating Manual. Certificate., Iae. Light And Sound Annunciator Exit. Current Consumption In Standby Mode Is 20 Ma, Sound Pressure Level At A Distance Of 1 M Is Up To 100 Db, Supply Voltage Is 12 V Dc, Protection Level Is Ip55, Operating Conditions Are From -30° To +55 ° C, Dimensions Are No More Than 300 X 100 X 30 Mm. St Rk 1189-2003. Passport/Operating Manual. Certificate., Iae. Wire Shvvp 2X0.75, Core Diameter - 1.2 Mm, Supplied In A Coil, Length In A Coil Is Not Less Than 200 M, Insulation - Pvc Plastic, Number Of Cores In The Cable - 2, Core Cross-Section - 0.75 Mm2, Cable Cross-Section - 0.75 Mm, Operating Conditions From -40° To +50 °C, Dimensions No More Than Ø 3.4 X 5.6 Mm. Gost 7399-97. Certificate., Iae. Two-Wire Communication Line Controller. Non-Volatile Event Buffer - 255, Connection To A Pc Via The Rs-485 Interface, Technical Readiness Time - No More Than 15 S, Number Of Connected Aus - 127, Device Programming - Uprog.Exe Program, Case Intrusion Sensor - Microcontact, External Electronic Id Reader - 1 Input, Communication Port (For Work In Iso Orion) - Rs-485, Orion Protocol, Two-Wire Line Length (Length/Section) - 600 M/0.75 Mm²; 700 M/0.9 Mm², Mounting Type - Wall-Mounted, Wall-Mounted Or On A Din Rail. Memory Capacity Of Touch Memory Keys, Cards Or Codes - 512, Light Indication On The Front Panel - 3 Led Indicators (Operation, Rs-485 And Dpls), Communication Interface With The Reader - Dallas Touch Memory (1-Wire, Μ-Lan), Wiegand, Aba-Trac, Supply Voltage - From 10.2 V To 28.4 V Dc, Degree Of Protection - Ip30, Operating Conditions From -30° To -30° To +55 °C, Dimensions No More Than 156 X 107 X 39 Mm. St Rk 1699-2007. Passport/Operating Manual. Certificate., Iae. Voice Notification Device. The Main Power Source Is Ac 220 V, 50 Hz. Backup Power Source - Rechargeable Battery 12V, 7Ah. Power Consumed From The Ac Mains Is No More Than 15 W. The Current Consumed From The Backup Power Source In Standby Mode Is No More Than 0.1A. The Average Current Consumption In Alert Mode Is 0.75A. The Units Technical Readiness Time For Operation Is No More Than 3 S. Operating Time From A Fully Charged Battery In Standby Mode Is No Less Than 24 Hours. Operating Time From A Fully Charged Battery In Alert Mode Is No Less Than 2 Hours. Time To Fully Charge A Discharged Battery Is No More Than 60 Hours. Maximum Battery Charge Current Is 0.25A. Maximum Output Power - 40 W. The Permissible Resistance Range Of The Ro Connection Circuit Is From 4 To 22 Ohms. Output Power Limitation Levels - 5. The Total Duration Of Voice Messages Is At Least 84 Seconds. Number Of Messages - No Less Than 128. Non-Volatile Event Buffer - No Less Than 256. Case Tamper Sensor. Communication Port - Rs-485. Electric Shock Protection Class - Ii. The Degree Of Protection Of The Shell Is Ip30. Resistance To Mechanical Stress Corresponds To Placement Category 03. Operating Temperature Range - From -10 To +55 °C. Relative Air Humidity - Up To 98% At +25 °C. Unit Weight (With Battery) - No More Than 2.95. Overall Dimensions Of The Block Are No More Than 211X165x89. St Rk 1189-2003. Passport/Operating Manual. Certificate., Iae. Reception And Control Device. Wired Alarm Loops (Al) - At Least 4. Voltage At Each Al Input - 24 V ÷ 19 V When Installing A Resistor. Max. Resistance Of Address Alarm Loop Wires Is 1 Kohm For Security Alarm Loops / 100 Ohm For Fire Alarm Alarm Loops. Ready For Work After Turning On The Power - No More Than 3 Seconds. Current Limitation In A Short-Circuited Loop Is 26.5 Ma (20 Ma Through A Triggered Detector). Non-Volatile Event Buffer - No Less Than 4088. Interface - Rs-485. Outputs - At Least 4 Pcs. The Unit Is Powered From An External Dc Source. Built-In Sound Alarm. The Housing Tamper Sensor Is A Microcontact. Mounting Type: Wall-Mounted, Wall-Mounted Or On A Din Rail. The Degree Of Protection Is At Least Ip30. Average Service Life Is At Least 10 Years. Operating Conditions From -40° To +50 °C; Humidity Up To 98%. Dimensions No More Than 156 X 107 X 39 Mm. Gost 27990-88. Passport/Operating Manual. Certificate., Iae. Fire Detector. Switched Current - Up To 25 Ma, Current Consumption In Standby Mode - No More Than 50 Ma, Installation Type - Wall-Mounted, Mounted. Degree Of Protection - Ip41, Operating Conditions From -30° To +50 °C, Humidity Up To 93%. Dimensions No More Than 95 X 91 X 33 Mm. St Rk 1301-2004. Passport/Operating Manual. Certificate., Iae. Manual Addressable Fire Detector, Zone Violation Detection Time - No More Than 300 Ms, Detector Technical Readiness Time - No More Than 15 S, Detector Programming - Uprog.Exe Program, Device Power Supply - Up To 11 W, Detector Current Consumption - No Less Than 0.5 Ma, Installation Type - Wall-Mounted, Degree Of Protection - Ip41, Operating Conditions From -30° To +55 °C, Dimensions No More 95 X 91 X 33 Mm. St Rk 1301-2004. Passport/Operating Manual. Certificate., Iae. Uninterruptible Power Supply. Redundant Power Supply, Presence Of An Audible Alarm, Number Of Indicators - 3, Battery Voltage Control (Charge Indication), Protection Against Excess Output Voltage - 2 Stages, Maximum Output Current - Not Less Than 2 A, Type Of Installation - Wall-Mounted, Mounted, Rated Output Current - 3 A, Degree Of Protection - Ip30, Operating Conditions From -10° To +40 °C, Humidity Up To 90%, Dimensions Not Over 255 X 310 X 85 Mm. Gost Iec 62040-1-2018. Certificate., Iae. The Box Is Universal. Operating Conditions From -50° To +50 °C, Dimensions No More Than 42 X 42 X 20 Mm. Color White, Material Plastic. Gost 31195.2.5-2012. Certificate., Iae. Speaker, Directional Angle 1Khz / 4 Khz / 8 Khz - 180° / 90° / 80°. Power - No More Than 3 W. Resistance - 8 Ohms. Frequency - 90 Hz - 16 Khz. Degree Of Protection - Ip41. Operating Conditions From -10° To +55 °C. Dimensions No More Than 121 × 121 × 61 Mm. St Rk 1189-2003. Passport/Operating Manual. Certificate., Iae. Cable Channel. Functional, Technical, Quality And Performance Characteristics. Designed For Laying Power Cables And Low-Current Networks For Outdoor Installation Indoors. Dimensions No More Than (Hxw) 40X16 Mm, Length No Less Than 2000 Mm. Color - White, System Type - Mounting Tray, Case Material - Plastic, Installation Method - Overhead. Certificate., Iae. The Luminaire Is Designed To Provide Emergency Backup Lighting In The Event Of A Power Outage. Number Of Leds - At Least 30 Pcs. Energy Efficiency Requirements Are At Least 120 Lm/W. Color Temperature - No Less Than 6500 K. Luminous Intensity - No Less Than 30X2500 Mcd. Light Source Power - At Least 1.5 W. Power Consumption From The Network Is No More Than 0.6 W. Battery Charging Time - 20 Hours. Supply Voltage - From Ac Mains From 187 To 242 V, Frequency 50 Hz. Replaceable Lithium-Ion Battery With A Voltage Of 3.7 V And A Capacity Of 1200 Mah. Overall Dimensions No More Than 202X55x30 Mm. Weight No More Than 0.17 Kg. Operating Temperature Range From - 0 To +40 °C. Gost Iec 60598-2-22-2016. Passport/Operating Manual. Certificate., Iae. The Battery Is Intended For Use As A Main Or Backup Power Source In Power Supplies, Office Equipment, And Security Systems. Battery Capacity - 7 A/H, Rated Voltage - 12 V. Dimensions No More Than 151 X 65 X 94-100 Mm (Lxwxh). Gost Iec 60896-2-2002. Certificate., Iae. Cable, Core Diameter - 0.5 Mm, Supplied In A Coil, Length In A Coil Is At Least 500 M, Insulation - Solid Polyethylene, Number Of Cores In The Cable - 2, Core Cross-Section - 0.2 Mm2, Cable Cross-Section - 0.5 Mm, Operating Conditions From -40° To +60 °C. St Rk 2339-2013. Certificate., Iae. The Display Unit Provides Light And Sound Indication Of The Status Of Sections (Zones) And Is Installed Inside The Protected (Protected) Object And Is Designed For Round-The-Clock Operation. Ready For Work After Turning On The Power - No More Than 2 Seconds. Built-In Sound Alarm. Programming The Block Is The Uprog.Exe Program. The Housing Tamper Sensor Is A Microswitch. Communication Port (For Work In Iso Orion) - Rs-485, Orion Protocol. Installation Type: Wall-Mounted, Mounted. Supply Voltage - From 10.2 V To 28.4 V Dc. Degree Of Protection - Ip20. Operating Conditions From -30° To +50°C, Humidity Up To 98%. Dimensions No Less Than 340 X 170 X 25.5 Mm. Gost 27990-88. Passport/Operating Manual. Certificate., Iae. Fire Detector, Response T From +64 To +76⁰С. The Contacts Are Normally Closed. Intrinsically Safe. St Rk 1188-2003. Passport/Operating Manual. Certificate.
Key Value
Tender Value
1,594,719 - KZT
Tender Documents
Global Tender Document
9ad70b63-e508-44be-82c8-7babb16553a7.html
Attachments
Additional Details Available on Click
  • Tendering Authority
  • Publication Document (Tender Document / Tender Notice)
Disclaimer

We take all possible care for accurate & authentic tender information. However, users are requested to refer to the original Tender Notice / Tender Document published by the Tender Issuing Agency before taking any decision regarding this tender.

Tell us about your Product / Services,

We will Find Tenders for you

TenderDetail
Loading tenders