Circuit Breaker 380 V, 100 A: Designed For Use In Three-Phase Electrical Networks, With A Rated Voltage Of 380/400 V And A Rated Current Of 100 A, Refers To Low-Voltage Switching Devices. The Device Is Designed To Protect The Electrical Circuit From Overload And Short Circuit. The Design Of The Circuit Breaker Is Usually Three-Pole (3P) Or, If Necessary, Four-Pole (3P+N). The Device Must Comply With The Requirements Of Gost Iec 60898-1 Or Gost Iec 60947-2, As Well As The Eaeu Tr. The Breaking Capacity (Short Circuit Current) Must Be At Least 4.5–10 Ka Or Selected In Accordance With The Design Load Of The Facility. Response Characteristic (Type) - C Or D, Depending On Operating Conditions. Installation Is Carried Out On A Din Rail Or In A Distribution Board, Intended For Use In Industrial, Administrative And Domestic Facilities., Power Cable Type Vvg 5×10 And Its Analogue According To The Standards Of The Republic Of Kazakhstan And The Eaeu: Vvgng(A) 5×10 Or Vvgng(A)-Ls 5×10, Meeting The Requirements Of Gost 31996-2012 And Technical Regulations Of The Eaeu Tr. The Cable Must Be Copper, With The Number Of Cores - 5, The Cross-Section Of Each Core - 10 Mm², With Pvc Insulation And Sheath. The Analogue Must Ensure The Transmission And Distribution Of Electricity In Stationary Installations At A Rated Voltage Of Up To 0.66/1 Kv. The Ng(A) Version Of The Cable Must Not Spread Fire When Laid In Groups, And The Ng(A)-Ls Version Must Additionally Have Reduced Smoke And Gas Emissions, Which Is Recommended For Use In Buildings With Large Numbers Of People, Including Medical And Administrative Institutions., The Power Panel Is Designed To Receive, Distribute And Protect Electrical Circuits. The Device Is Used In Single-Phase And Three-Phase Electrical Networks With Voltages Up To 400 V. The Panel Body Must Be Made Of Impact-Resistant, Self-Extinguishing Plastic Or Metal With An Anti-Corrosion Coating. The Design Must Provide For External (Hinged) Installation On A Wall Or A Special Support. Internal Installation Must Be Carried Out On A Din Rail With The Possibility Of Placing Circuit Breakers, Residual Current Devices And Other Modular Equipment. The Switchboard Must Be Equipped With N (Neutral) And Pe (Grounding) Buses. The Door Can Be Transparent Or Opaque, With The Possibility Of Sealing And Protection Against Unauthorized Access. The Degree Of Protection Of The Shell Is Not Lower Than Ip40. The Switchboard Must Be Suitable For Use Both Indoors And, If Necessary, Outdoors (Depending On The Installation Location). The Product Must Comply With The Requirements Of Gost Iec 61439-3 And Technical Regulations Of The Eaeu. It Is Permitted To Supply Equivalent Products That Meet The Specified Technical Specifications.
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.